Supply of Multiplex Real Time Rt Pcr Kit For Detection Of Respiratory Pathogens 1... Tender

RAJIV GANDHI SUPER SPECIALITY HOSPITAL has floated a tender for Supply of Multiplex Real Time Rt Pcr Kit For Detection Of Respiratory Pathogens 1 1. Specimen Respiratory Samples. 2. The Test Should Be Able To Detect A Minimum Of The Following Pathogens: Influenza .... The project location is Tahirpur, Delhi, India. The reference number is 2024_RGSSH_266149 and it is closing on 10 Mar 2025. Suppliers can request Register free of cost to get the complete Tender details and download the document.

Expired Tender

Procurement Summary

State : Delhi

Summary : Supply of Multiplex Real Time Rt Pcr Kit For Detection Of Respiratory Pathogens 1 1. Specimen Respiratory Samples. 2. The Test Should Be Able To Detect A Minimum Of The Following Pathogens: Influenza ...

Deadline : 10 Mar 2025

Other Information

Notice Type : Tender

TOT Ref.No.: 115013254

Document Ref. No. : 2024_RGSSH_266149

Financier : Self Financed

Purchaser Ownership : Public

Document Fees : Refer Document

Tender Value : ₹ 15000000

EMD : ₹ 308500

Purchaser's Detail

Name :Login to see tender_details

Address : Login to see tender_details

Email : Login to see tender_details

Login to see details

Tender Details

Tenders are invited for Supply of Multiplex Real Time Rt Pcr Kit For Detection Of Respiratory Pathogens 1 1. Specimen Respiratory Samples. 2. The Test Should Be Able To Detect A Minimum Of The Following Pathogens: Influenza A H1N1, Influenza B, Rhinovirus, Coronavirus Nl63, 229E, Oc43, Hku1, Parainfluenza 1, 2, 3, 4, Human Metapneumovirus A B, Bocavirus, Mycoplasma Pneumoniae, Respiratory Syncytial Virus A B, Adenovirus, Enterovirus, Parechovirus, Chlamydia Pneumoniae, Staphylococcus Aureus, Streptococcus Pneumoniae, Haemophilus Influenzae, Influenza C, Pneumocystis Jirovecii, Haemophilus Influenzae Type B, Bordetella Spp. Except Bordetella Parapertussis, Moraxella Catarrhalis, Klebsiella Pneumoniae, Legionella Spp., Salmonella Spp. 3. The Reagents Must Be Sufficient In Quantity To Enable Testing Of Small Number Of Samples At A Time. 4. There Should Not Be Any Cross Reactivity · High Sensitivity, Specificity And Reproducibility. No Inter-Assay Variability Us-Fda Or Ce-Ivd Approved. Qty 1 Nos at Tahirpur
EMD - 308500

Tender Value - 15000000
Supply of Multiplex Real Time Rt Pcr Kit For Detection Of Respiratory Pathogens 1 1. Specimen Respiratory Samples. 2. The Test Should Be Able To Detect A Minimum Of The Following Pathogens: Influenza A H1N1, Influenza B, Rhinovirus, Coronavirus Nl63, 229E, Oc43, Hku1, Parainfluenza 1, 2, 3, 4, Human Metapneumovirus A B, Bocavirus, Mycoplasma Pneumoniae, Respiratory Syncytial Virus A B, Adenovirus, Enterovirus, Parechovirus, Chlamydia Pneumoniae, Staphylococcus Aureus, Streptococcus Pneumoniae, Haemophilus Influenzae, Influenza C, Pneumocystis Jirovecii, Haemophilus Influenzae Type B, Bordetella Spp. Except Bordetella Parapertussis, Moraxella Catarrhalis, Klebsiella Pneumoniae, Legionella Spp., Salmonella Spp. 3. The Reagents Must Be Sufficient In Quantity To Enable Testing Of Small Number Of Samples At A Time. 4. There Should Not Be Any Cross Reactivity · High Sensitivity, Specificity And Reproducibility. No Inter-Assay Variability Us-Fda Or Ce-Ivd Approved. Qty 1 Nos at Tahirpur

Documents

 Tender Notice