Supply of CPAP device: General: 1. Should be light weight ( less than 1.5kgs) and... Tender

SANJAY GANDHI POST GRADUATE INSTITUTE OF MEDICAL SCIENCES, LUCKNOW has floated a tender for Supply of CPAP device: General: 1. Should be light weight ( less than 1.5kgs) and portable. 2. Should have Manual & auto mode. 3. Should be able to detect and respond to Apnea, Hypopnea, central apnea, Snoring and RERA. 4. Should be certified to use. The project location is Lucknow, Uttar Pradesh, India. The reference number is PGI/HRF/Surg-807/2022-23, Advt No. I/58/HRF/2022-23/Category A/2219 and it is closing on 31 Dec 2022. Suppliers can request Register free of cost to get the complete Tender details and download the document.

Expired Tender

Procurement Summary

State: Uttar Pradesh

Summary: Supply of CPAP device: General: 1. Should be light weight ( less than 1.5kgs) and portable. 2. Should have Manual & auto mode. 3. Should be able to detect and respond to Apnea, Hypopnea, central apnea, Snoring and RERA. 4. Should be certified to use

Deadline: 31 Dec 2022

Other Information

Notice Type: Tender

TOT Ref.No.: 76241857

Document Ref. No.: PGI/HRF/Surg-807/2022-23, Advt No. I/58/HRF/2022-23/Category A/2219

Financier: Self Financed

Purchaser Ownership: Public

Document Fees: Refer Document

Tender Value: Refer Document

EMD: ₹ 50000

Purchaser's Detail

Name: Login to see tender_details

Address: Login to see tender_details

Email: Login to see tender_details

Login to see details

Tender Details

Tenders are invited for Supply of CPAP device: General: 1. Should be light weight ( less than 1.5kgs) and portable. 2. Should have Manual & auto mode. 3. Should be able to detect and respond to Apnea, Hypopnea, central apnea, Snoring and RERA. 4. Should be certified to use on patients weighing 30 kgs & above. 5. Should display device functions like current therapy pressure, operating hours, set therapy pressure, sleep ramp, automatic start/stop. 6. Should be US FDA Approved. 7. The pressure range should be between 4-20 cm H2O adjustable in 0.5 cm H2O steps. 8. Should have low sound level of less than 35 db. 9. Should have sleep ramp adjustable from 0-45 min in 5 min intervals. 10. Should have leak compensation up to 60 Liters. 11. System should be able to compensate for variable resistance related to different mask like nasal/minimal contact mask etc. 12. Should provide flow-based pressure relief at the beginning of exhalation and softens the pressure transition from inhalation to exhalation to provide additional comfort. 13. Should have automatic altitude compensation/adjustment. 14. System should have advanced technology to prevent rain out. Hardware: 1. Compliance data should be stored on external memory card which can be accessed through nonproprietary card readers 2. Should be able to operate on 100V-240V AC. 3. Should be provided with integrated heated humidifier & humidifier chamber should be isolated from the inner parts of the device to prevent damage due to water seepage. General Terms & Conditions: 1. Should be supplied with carry bag. 2. Should have a warranty of 3 years . 3. Manufacturer should have a wide national network and office with complete Service, Repair and application backup capability for the quoted equipment. 4. Should be provided with reusable nasal mask qty 1, 5. Should be Provided with Hose Pipe qty one. 6. Facility for downloading compliance data from the equipment at the hospital has to be provided. 7. Should be US FDA Approved, Qty: 50 for a Period of Two Years EMD: 50000

Documents

 Tender Notice