Flame Photometer with Compressor, Size or Dimension- 260 Multiply 220 Multiply 195Mm... Tender

DEPARTMENT OF HIGHER EDUCATION has floated a tender for Flame Photometer with Compressor, Size or Dimension- 260 Multiply 220 Multiply 195Mm (L Multiply B Multiply H) - Filters- Na & K Supplied (Ca and Li & Ba are Optional at E Multiply T... (Quantity Required: 1 Pieces). The project location is Papum Pare, Arunachal Pradesh, India. The reference number is GEM/2022/B/2435306 and it is closing on 01 Sep 2022. Suppliers can request Register free of cost to get the complete Tender details and download the document.

Expired Tender

Procurement Summary

State : Arunachal Pradesh

Summary : Flame Photometer with Compressor, Size or Dimension- 260 Multiply 220 Multiply 195Mm (L Multiply B Multiply H) - Filters- Na & K Supplied (Ca and Li & Ba are Optional at E Multiply T... (Quantity Required: 1 Pieces)

Deadline : 01 Sep 2022

Other Information

Notice Type : Tender

TOT Ref.No.: 70422550

Document Ref. No. : GEM/2022/B/2435306

Financier : Self Financed

Purchaser Ownership : Public

Document Fees : Refer Document

Tender Value : Refer Document

EMD : ₹ 50000.00

Purchaser's Detail

Name :Login to see tender_details

Address : Login to see tender_details

Email : Login to see tender_details

Login to see details

Tender Details

Item Description: Size or Dimension- 260 multiply 220 multiply 195mm (L multiply B multiply H) - Filters- Na & K Supplied (Ca and Li & Ba are optional at e multiply tra cost) - Atomizer- A multiply ial Flow Type - Average Time- In-built in Software - Calibration- upto-5 point Calibration with curve fitting software. Curve Accuracy- lesser than 2percent error when 3 ppm Na or K and 5 ppm and Li are set as ma multiply imum Standards - Detection- Silicon Photodiode - Flame Design- Squre - Flame System- LPG and dry oil free air - Gas Control- Adjustable with knobs. Ignition System- Auto ignition - Power- 230 V +- 10percent AC and 50 Hz - lesser than 1percent coefficient of variation for 20 consecutive samples using 10ppm Na are set as ma multiply Standards. Sensitivity- General- Na- 0.5 ppm and K- 0.5 ppm and Li- 0.5 ppm and Curve Accuracy- lesser than 2percent error when 3 ppm Na or K and 5 ppm and Li are set as ma multiply imum Standards. Detection- Silicon Photodiode - Flame Design- Squre Flame System- LPG and dry oil free air Gas Control- Adjustable with knobs Ignition System- Auto ignition Power- 230 V +- 10percent AC and 50 Hz lesser than 1percent coefficient of variation for 20 consecutive samples using 10ppm Na are set as ma multiply Standards. Sensitivity- General- Na- 0.5 ppm and K- 0.5 ppm and Li- 0.5 ppm and Ca- 158 ppm and Ba- 50ppm Make or Model- Microprocessor Flame Photometer S- 935
Item Quantity: 1
Unit of Measure: Pieces
Delivery Period (In number of days): 40
Start Date: 16-08-2022 01:05 PM
End Date: 01-09-2022 02:00 PM
EMD Amount: 50000

Documents

 Tender Notice

Bid_Document_3679685.pdf

Specification_Document.pdf

BOQ_Document.csv