Flame Photometer with Compressor (Quantity Required: 1 Pieces) Tender, Arunachal Pradesh - 82339707

DEPARTMENT OF HIGHER EDUCATION has floated a tender for Flame Photometer with Compressor (Quantity Required: 1 Pieces). The project location is Papum Pare, Arunachal Pradesh, India. The reference number is GEM/2023/B/3399899 and it is closing on 15 May 2023. Suppliers can request Register free of cost to get the complete Tender details and download the document.

Expired Tender

Procurement Summary

State : Arunachal Pradesh

Summary : Flame Photometer with Compressor (Quantity Required: 1 Pieces)

Deadline : 15 May 2023

Other Information

Notice Type : Tender

TOT Ref.No.: 82339707

Document Ref. No. : GEM/2023/B/3399899

Financier : Self Financed

Purchaser Ownership : Public

Document Fees : Refer Document

Tender Value : Refer Document

EMD : ₹ 46000

Purchaser's Detail

Name :Login to see tender_details

Address : Login to see tender_details

Email : Login to see tender_details

Login to see details

Tender Details

Item Description: Size or Dimension- 260 x 220 x 195mm (L x B x H) - Filters- Na & K Supplied (Ca and Li & Ba are optional at e x tra cost) - Atomizer- A x ial Flow Type - Average Time- In-built in Software - Calibration- upto-5 point Calibration with curve fitting software. Curve Accuracy- lesser than 2percent error when 3 ppm Na or K and 5 ppm and Li are set as ma x imum Standards - Detection- Silicon Photodiode - Flame Design- Squre - Flame System- LPG and dry oil free air - Gas Control- Adjustable with knobs. Ignition System- Auto ignition - Power- 230 V +- 10percent AC and 50 Hz - lesser than 1percent coefficient of variation for 20 consecutive samples using 10ppm Na are set as ma x Standards. Sensitivity- General- Na- 0.5 ppm and K- 0.5 ppm and Li- 0.5 ppm and Curve Accuracy- lesser than 2percent error when 3 ppm Na or K and 5 ppm and Li are set as ma x imum Standards. Detection- Silicon Photodiode - Flame Design- Squre Flame System- LPG and dry oil free air Gas Control- Adjustable with knobs Ignition System- Auto ignition Power- 230 V +- 10percent AC and 50 Hz lesser than 1percent coefficient of variation for 20 consecutive samples using 10ppm Na are set as ma x Standards. Sensitivity- General- Na- 0.5 ppm and K- 0.5 ppm and Li- 0.5 ppm and Ca- 158 ppm and Ba- 50ppm. Make any reputed brand.
BOQ Title: Laboratory Equipment
Item Title: Flame Photometer with Compressor
Item Quantity: 1
Unit of Measure: Pieces
Delivery Period (In number of days): 40
Start Date: 29-04-2023 1:37 PM
End Date: 15-05-2023 2:00 PM
EMD Amount: 46000

Documents

 Tender Notice

Bid_Document_4716238.pdf

Specification_Document.pdf

BOQ_Document.csv