32 Channel Video Eeg System (Quantity Required: 1 No) Tender, Jharkhand - 81795010

ALL INDIA INSTITUTE OF MEDICAL SCIENCES (AIIMS), NEW DELHI has floated a tender for 32 Channel Video Eeg System (Quantity Required: 1 No). The project location is Deoghar, Jharkhand, India. The reference number is GEM/2023/B/3359895 and it is closing on 22 May 2023. Suppliers can request Register free of cost to get the complete Tender details and download the document.

Expired Tender

Procurement Summary

State : Jharkhand

Summary : 32 Channel Video Eeg System (Quantity Required: 1 No)

Deadline : 22 May 2023

Other Information

Notice Type : Tender

TOT Ref.No.: 81795010

Document Ref. No. : GEM/2023/B/3359895

Financier : Self Financed

Purchaser Ownership : Public

Document Fees : Refer Document

Tender Value : Refer Document

EMD : ₹ 120000

Purchaser's Detail

Name :Login to see tender_details

Address : Login to see tender_details

Email : Login to see tender_details

Login to see details

Tender Details

Item Description: The system shall be manufactured by an ISO 9001 US FDA and CE and ISO 13485 certified manufacturer The system shall be certified and tested by a recognized test organization for compliance to IEC 60601 2 26 Particular Safety of Electroencephalography Equipment Video EEG recording system based on Windows 10 Operating system with minimum CPU Configuration of Intel i3 Processor 8GB RAM 1 TB hard disk capacity DVD-Writer 24 inch monitor High Quality EEG Amplifier should available with Industry Standard Ethernet Amplifier Interface shall provide at least 34 electrode inputs 32 EEG Plus 2 DC which are optically isolated and certified to at least type CF classification The Video EEG amplifier shall be equipped with a minimum of 16 bit Analog-to-Digital Converter ADC CMRR 115 dB Sampling frequency of 2000 Hz and input Impedance of 100M and bandwidth of 0.05 to 500Hz The amplifier system should have facility to configure at least 9 pair of electrode inputs as bipolar inputs appropriate to accept Polysomnography signals and shall have integrated Pulse Oximeter The system should have a method to detect a poor electrode connection and provide a notification to the user and also should be possible to test Continuous electrode impedance It shall be possible to View the EEG data in any PC without loading any software System should be with Synchronized Video and Remote Control Color PTZ Camera Should have Facility to record selective video by allowing automatic video recording only when specific user defined events occur The Patient Data Management software shall be available with optional hardware and software to provide an interface between the Patient Data Management software and a Hospital Information System HIS via an HL 7 Health Level 7 communications protocol The System should have Networking facility The system should be supplied with complete set of electrodes and consumables
Item Category: 32 Channel Video EEG System
BOQ Title: 32 Ch EEG
Item Title: 32 Channel Video Eeg System
Item Quantity: 1
Unit of Measure: No
Delivery Period (In number of days): 60
Start Date: 18-04-2023 11:06 AM
End Date: 22-05-2023 4:00 PM
EMD Amount: 120000

Documents

 Tender Notice

Bid_Document_4672873.pdf

Specification_Document.pdf

BOQ_Document.csv


Neshcap