CORPORATE OFFICE, GURGAON has floated a tender for Supply of S and S make isolator spares for NWR of POWERGRID, Qty: 828. The project location is Bikaner, Rajasthan, India. The reference number is - and it is closing on 10 Nov 2026. Suppliers can request Register free of cost to get the complete Tender details and download the document.
Procurement Summary
State: Rajasthan
Summary: Supply of S and S make isolator spares for NWR of POWERGRID, Qty: 828
Deadline: 10 Nov 2026
Posting Date: 31 Oct 2026
Other Information
Notice Type: Tender
TOT Ref.No.: 151794327
Document Ref. No.: Login to see detail
Financier: Self Financed
Purchaser Ownership: Public
Document Fees: Refer Document
Tender Value: Refer Document
EMD: Refer Document
Purchaser's Detail
Name: Login to see details
Address: Login to see details
Email: Login to see details
Login to see detailsTender Details
Descrption: Login to see details
IMP: Login to see details
Contact Details: Login to see details
Documents
| # | Title | Description | Qty | Unit | Delivery (Days) |
|---|---|---|---|---|---|
| 1 | 765 kV Knee Type, 3150 Ampere at Bhadla-2, Fatehgarh-2, Chittorgarh, Bhadla | Close Contactor with Add ON (The site-wise quantity details shall be as per Annexure-II) | 8 | No | 152 |
| 2 | 765 kV Knee Type, 3150 Ampere at Bhadla-2, Fatehgarh-2, Chittorgarh, Bhadla of NWR region | Open Contactor with Add ON (The site-wise quantity details shall be as per Annexure-II) | 8 | No | 152 |
| 3 | 765 kV Knee Type, 3150 Ampere at Bhadla-2, Fatehgarh-2, Chittorgarh, Bhadla of NWR | INTERLOCK Contactor (The site-wise quantity details shall be as per Annexure-II) | 8 | No | 152 |
| 4 | 765 kV Knee Type, 3150 Ampere at Bhadla-2, Fatehgarh-2, Chittorgarh, Bhadla of NWR region POWERGRID | Master - Individual Switch (The site-wise quantity details shall be as per Annexure-II) | 16 | No | 152 |
| 5 | 765 kV Knee Type, 3150 Ampere at Bhadla-2, Fatehgarh-2, Chittorgarh, Bhadla sites of NWR region | Local - Remote - Manual Switch (The site-wise quantity details shall be as per Annexure-II) | 16 | No | 152 |
| 6 | 765 kV Knee Type, 3150 Ampere at Bhadla-2, Fatehgarh-2, Chittorgarh, Bhadla sites | Limit Swtich (The site-wise quantity details shall be as per Annexure-II) | 16 | No | 152 |
| 7 | 765 kV Knee Type, 3150 Ampere at Bhadla-2, Fatehgarh-2, Chittorgarh, Bhadla sites of NWR region POWERGRID | Auxiliary Switch (The site-wise quantity details shall be as per Annexure-II) | 8 | No | 152 |
| 8 | 765 kV Knee Type, 3150 Ampere at Bhadla-2, Fatehgarh-2, Chittorgarh, Bhadla sites of POWERGRID | Overload Relay WITH CONTACTOR (The site-wise quantity details shall be as per Annexure-II) | 8 | No | 152 |
| 9 | 765 kV Knee Type, 3150 Ampere at Bhadla-2, Fatehgarh-2, Chittorgarh, Bhadla sites, POWERGRID | 3 Pole ON- OFF Rotary Switch (The site-wise quantity details shall be as per Annexure-II) | 16 | No | 152 |
| 10 | 765 kV Knee Type, 3150 Ampere at Bhadla-2, Fatehgarh-2, Bikaner, Chittorgarh, Bhadla of NWR region | Motor (The site-wise quantity details shall be as per Annexure-II) | 22 | No | 152 |
| 11 | 765 kV Knee Type, 3150 Ampere at Bhadla-2, Fatehgarh-2, Chittorgarh, Bhadla, POWERGRID | PUSH Button ON (The site-wise quantity details shall be as per Annexure-II) | 16 | No | 152 |
| 12 | 765 kV Knee Type, 3150 Ampere at Bhadla-2, Fatehgarh-2, Chittorgarh, Bhadla, NWR region | PUSH Button OFF (The site-wise quantity details shall be as per Annexure-II) | 16 | No | 152 |
| 13 | 765 kV Knee Type, 3150 Ampere at Bhadla-2, Fatehgarh-2, Chittorgarh, Bhadla, NWR region,POWERGRID | PUSH Button Manual (The site-wise quantity details shall be as per Annexure-II) | 14 | No | 152 |
| 14 | 765 kV Knee Type, 3150 Ampere at Bhadla-2, Fatehgarh-2, Bhadla | PUSH Button Stop (The site-wise quantity details shall be as per Annexure-II) | 12 | No | 152 |
| 15 | 765 kV Knee Type, 3150 Ampere at Bhadla-2, Fatehgarh-2, Bhadla of NWR region | MOM BOX ( Isolator ) (The site-wise quantity details shall be as per Annexure-II) | 12 | No | 152 |
| 16 | 765 kV Knee Type, 3150 Ampere at Bhadla-2, Fatehgarh-2, Bhadla of NWR | DOWN PIPE ( From MOM Box to Isolator ) (The site-wise quantity details shall be as per Annexure-II) | 26 | No | 152 |
| 17 | 765 kV Knee Type, 3150 Ampere at Bhadla-2, Fatehgarh-2, Bikaner, Chittorgarh, Bhadla of NWR | MALE Copper Fingers ( set ) (The site-wise quantity details shall be as per Annexure-II) | 18 | No | 152 |
| 18 | 765 kV Knee Type, 3150 Ampere at Bhadla-2, Fatehgarh-2, Bikaner, Chittorgarh, Bhadla of NWR region POWERGRID | FEMALE Copper Fingers ( set ) (The site-wise quantity details shall be as per Annexure-II) | 18 | No | 152 |
| 19 | 765 kV Knee Type, 3150 Ampere at Bhadla-2, Fatehgarh-2, Bikaner,Bhadla | MOVING CONTACT ASSEMBLY (The site-wise quantity details shall be as per Annexure-II) | 8 | No | 152 |
| 20 | 765 kV Knee Type, 3150 Ampere at Bhadla-2, Fatehgarh-2, Bhadla of NWR region POWERGRID | DOWN PIPE ( From MOM Box to Earth Switch ) (The site-wise quantity details shall be as per Annexure-II) | 18 | No | 152 |
| 21 | 765 kV Knee Type, 3150 Ampere at Bhadla-2, Fatehgarh-2, Bikaner, Bhadla of NWR region | Earth Switch Male Contact (The site-wise quantity details shall be as per Annexure-II) | 14 | No | 152 |
| 22 | 765 kV Knee Type, 3150 Ampere at Bhadla-2, Fatehgarh-2, Bikaner, Bhadla of NWR region POWERGRID | Earth Switch Female Contact (The site-wise quantity details shall be as per Annexure-II) | 14 | No | 152 |
| 23 | 765 kV Knee Type, 3150 Ampere at Bhadla-2, Fatehgarh-2, Bhadla sites of NWR region | MOM Box ( Earth Switch ) (The site-wise quantity details shall be as per Annexure-II) | 6 | No | 152 |
| 24 | 400 kV DBR, 3150 Ampere at Bhadla-2, Fatehgarh-2 | Close Contactor with Add ON (The site-wise quantity details shall be as per Annexure-II) | 4 | No | 152 |
| 25 | 400 kV DBR, 3150 Ampere at Bhadla-2, Fatehgarh-2 of NWR region | Open Contactor with Add ON (The site-wise quantity details shall be as per Annexure-II) | 4 | No | 152 |
| 26 | 400 kV DBR, 3150 Ampere at Bhadla-2, Fatehgarh-2 of NWR | INTERLOCK Contactor (The site-wise quantity details shall be as per Annexure-II) | 4 | No | 152 |
| 27 | 400 kV DBR, 3150 Ampere at Bhadla-2, Fatehgarh-2 of NWR region POWERGRID | Master - Individual Switch (The site-wise quantity details shall be as per Annexure-II) | 8 | No | 152 |
| 28 | 400 kV DBR, 3150 Ampere at Bhadla-2, Fatehgarh-2 sites of NWR region | Local - Remote - Manual Switch (The site-wise quantity details shall be as per Annexure-II) | 8 | No | 152 |
| 29 | 400 kV DBR, 3150 Ampere at Bhadla-2, Fatehgarh-2 sites | Limit Swtich (The site-wise quantity details shall be as per Annexure-II) | 8 | No | 152 |
| 30 | 400 kV DBR, 3150 Ampere at Bhadla-2, Fatehgarh-2 sites of NWR region POWERGRID | Auxiliary Switch (The site-wise quantity details shall be as per Annexure-II) | 4 | No | 152 |
| 31 | 400 kV DBR 3150 Ampere at Bhadla-2, Fatehgarh-2 sites of POWERGRID | Overload Relay WITH CONTACTOR (The site-wise quantity details shall be as per Annexure-II) | 4 | No | 152 |
| 32 | 400 kV DBR, 3150 Ampere at Bhadla-2, Fatehgarh-2 sites, POWERGRID | 3 Pole ON- OFF Rotary Switch (The site-wise quantity details shall be as per Annexure-II) | 8 | No | 152 |
| 33 | 400 kV DBR, 3150 Ampere at Bhadla-2, Fatehgarh-2, Bikaner, Ajmer | Motor (The site-wise quantity details shall be as per Annexure-II) | 16 | No | 152 |
| 34 | 400 kV DBR, 3150 Ampere at Bhadla-2, Fatehgarh-2, POWERGRID | PUSH Button ON (The site-wise quantity details shall be as per Annexure-II) | 8 | No | 152 |
| 35 | 400 kV DBR, 3150 Ampere at Bhadla-2, Fatehgarh-2, NWR region | PUSH Button OFF (The site-wise quantity details shall be as per Annexure-II) | 8 | No | 152 |
| 36 | 400 kV DBR, 3150 Ampere at Bhadla-2, Fatehgarh-2, NWR region,POWERGRID | PUSH Button Manual (The site-wise quantity details shall be as per Annexure-II) | 8 | No | 152 |
| 37 | 400 kV DBR, 3150 Ampere at Bhadla-2, Fatehgarh-2, NWR, POWERGRID | PUSH Button Stop (The site-wise quantity details shall be as per Annexure-II) | 8 | No | 152 |
| 38 | 400 kV DBR, 3150 Ampere at Bhadla-2, Fatehgarh-2 sites, NWR, POWERGRID | MOM BOX (The site-wise quantity details shall be as per Annexure-II) | 8 | No | 152 |
| 39 | 400 kV DBR, 3150 Ampere at Bhadla-2, Fatehgarh-2 sites, NWR region, POWERGRID | DOWN PIPE ( From MOM Box to Isolator ) (The site-wise quantity details shall be as per Annexure-II) | 12 | No | 152 |
| 40 | 400 kV DBR, 3150 Ampere at Bhadla-2, Fatehgarh-2, Bikaner of NWR region | MALE Copper Blades ( set ) (The site-wise quantity details shall be as per Annexure-II) | 18 | No | 152 |
| 41 | 400 kV DBR, 3150 Ampere at Bhadla-2, Fatehgarh-2, Bikaner | FEMALE Copper Fingers ( set ) (The site-wise quantity details shall be as per Annexure-II) | 18 | No | 152 |
| 42 | 400 kV DBR, 3150 Ampere at Bhadla-2, Fatehgarh-2 sites, NWR | DOWN PIPE ( From MOM Box to Earth Switch ) (The site-wise quantity details shall be as per Annexure-II) | 12 | No | 152 |
| 43 | 400 kV DBR, 3150 Ampere at Bhadla-2, Fatehgarh-2, Bikaner of NWR | Earth Switch Male Contact (The site-wise quantity details shall be as per Annexure-II) | 10 | No | 152 |
| 44 | 400 kV DBR, 3150 Ampere at Bhadla-2, Fatehgarh-2, Bikaner of NWR region POWERGRID | Earth Switch Female Contact (The site-wise quantity details shall be as per Annexure-II) | 10 | No | 152 |
| 45 | 400 kV DBR, 3150 Ampere at Bhadla-2, Fatehgarh-2 sites, NWR region | MOM Box ( Earth Switch ) (The site-wise quantity details shall be as per Annexure-II) | 4 | No | 152 |
| 46 | 400 kV DBR, 3150 Ampere at Bhadla-2, Fatehgarh-2, Bikaner, Ajmer of NWR region POWERGRID | Isolator Moving Arms (Moving Contact Assembly (Per No)) (The site-wise quantity details shall be as per Annexure-II) | 20 | No | 152 |
| 47 | 220 kV DBR, 1600 Ampere at Bhadla-2, Fatehgarh-2 of NWR region | Close Contactor with Add ON (The site-wise quantity details shall be as per Annexure-II) | 4 | No | 152 |
| 48 | 220 kV DBR, 1600 Ampere at Bhadla-2, Fatehgarh-2 of NWR | Open Contactor with Add ON (The site-wise quantity details shall be as per Annexure-II) | 4 | No | 152 |
| 49 | 220 kV DBR, 1600 Ampere at Bhadla-2, Fatehgarh-2 of NWR region POWERGRID | INTERLOCK Contactor (The site-wise quantity details shall be as per Annexure-II) | 4 | No | 152 |
| 50 | 220 kV DBR, 1600 Ampere at Bhadla-2, Fatehgarh-2 sites of NWR region | Local - Remote - Manual Switch (The site-wise quantity details shall be as per Annexure-II) | 12 | No | 152 |
| 51 | 220 kV DBR, 1600 Ampere at Bhadla-2, Fatehgarh-2 sites | Limit Swtich (The site-wise quantity details shall be as per Annexure-II) | 12 | No | 152 |
| 52 | 220 kV DBR, 1600 Ampere at Bhadla-2, Fatehgarh-2 sites of NWR region POWERGRID | Auxiliary Switch (The site-wise quantity details shall be as per Annexure-II) | 8 | No | 152 |
| 53 | 220 kV DBR, 1600 Ampere at Bhadla-2, Fatehgarh-2 sites of POWERGRID | Overload Relay WITH CONTACTOR (The site-wise quantity details shall be as per Annexure-II) | 4 | No | 152 |
| 54 | 220 kV DBR, 1600 Ampere at Bhadla-2, Fatehgarh-2 sites, POWERGRID | 3 Pole ON- OFF Rotary Switch (The site-wise quantity details shall be as per Annexure-II) | 12 | No | 152 |
| 55 | 220 kV DBR, 1600 Ampere at Bhadla-2, Fatehgarh-2, Bikaner | Motor (The site-wise quantity details shall be as per Annexure-II) | 14 | No | 152 |
| 56 | 220 kV DBR, 1600 Ampere at Bhadla-2, Fatehgarh-2, POWERGRID | PUSH Button ON (The site-wise quantity details shall be as per Annexure-II) | 8 | No | 152 |
| 57 | 220 kV DBR, 1600 Ampere at Bhadla-2, Fatehgarh-2, NWR region | PUSH Button OFF (The site-wise quantity details shall be as per Annexure-II) | 8 | No | 152 |
| 58 | 220 kV DBR, 1600 Ampere at Bhadla-2, Fatehgarh-2, NWR region,POWERGRID | PUSH Button Manual (The site-wise quantity details shall be as per Annexure-II) | 8 | No | 152 |
| 59 | 220 kV DBR, 1600 Ampere at Bhadla-2, Fatehgarh-2, NWR, POWERGRID | PUSH Button Stop (The site-wise quantity details shall be as per Annexure-II) | 8 | No | 152 |
| 60 | 220 kV DBR, 1600 Ampere at Bhadla-2, Fatehgarh-2 sites, NWR, POWERGRID | MOM BOX (The site-wise quantity details shall be as per Annexure-II) | 8 | No | 152 |
| 61 | 220 kV DBR, 1600 Ampere at Bhadla-2, Fatehgarh-2 sites, NWR region, POWERGRID | DOWN PIPE ( From MOM Box to Isolator ) (The site-wise quantity details shall be as per Annexure-II) | 12 | No | 152 |
| 62 | 220 kV DBR, 1600 Ampere at Bhadla-2, Fatehgarh-2 sites, NWR | MALE Copper Blades ( set ) (The site-wise quantity details shall be as per Annexure-II) | 12 | No | 152 |
| 63 | 220 kV DBR, 1600 Ampere at Bhadla-2, Fatehgarh-2 sites, NWR region | FEMALE Copper Fingers ( set ) (The site-wise quantity details shall be as per Annexure-II) | 12 | No | 152 |
| 64 | 220 kV DBR, 1600 Ampere at Bhadla-2, Fatehgarh-2 | DOWN PIPE ( From MOM Box to Earth Switch ) (The site-wise quantity details shall be as per Annexure-II) | 20 | No | 152 |
| 65 | 220 kV DBR, 1600 Ampere at Bhadla-2, Fatehgarh-2, Bikaner of NWR region | Earth Switch Male Contact (The site-wise quantity details shall be as per Annexure-II) | 12 | No | 152 |
| 66 | 220 kV DBR, 1600 Ampere at Bhadla-2, Fatehgarh-2, Bikaner of NWR | Earth Switch Female Contact (The site-wise quantity details shall be as per Annexure-II) | 12 | No | 152 |
| 67 | 220 kV DBR, 1600 Ampere at Bhadla-2, Fatehgarh-2, Bikaner of NWR region POWERGRID | MOM Box ( Earth Switch ) (The site-wise quantity details shall be as per Annexure-II) | 10 | No | 152 |
| 68 | 220 kV DBR, 1600 Ampere at Bhadla-2, Fatehgarh-2, Bikaner sites of NWR region | Isolator Moving Arms (Moving Contact Assembly (Per No)) (The site-wise quantity details shall be as per Annexure-II) | 14 | No | 152 |
| 69 | 72.5 kV DBR, 1250 Ampere at Bhadla-2, Fatehgarh-2 | Close Contactor with Add ON (The site-wise quantity details shall be as per Annexure-II) | 4 | No | 152 |
| 70 | 72.5 kV DBR, 1250 Ampere at Bhadla-2, Fatehgarh-2 of NWR region | Open Contactor with Add ON (The site-wise quantity details shall be as per Annexure-II) | 4 | No | 152 |
| 71 | 72.5 kV DBR, 1250 Ampere at Bhadla-2, Fatehgarh-2 of NWR | INTERLOCK Contactor (The site-wise quantity details shall be as per Annexure-II) | 4 | No | 152 |
| 72 | 72.5 kV DBR, 1250 Ampere at Bhadla-2, Fatehgarh-2 of NWR region POWERGRID | Local - Remote - Manual Switch (The site-wise quantity details shall be as per Annexure-II) | 4 | No | 152 |
| 73 | 72.5 kV DBR, 1250 Ampere at Bhadla-2, Fatehgarh-2 sites of NWR region | Limit Swtich (The site-wise quantity details shall be as per Annexure-II) | 4 | No | 152 |
| 74 | 72.5 kV DBR, 1250 Ampere at Bhadla-2, Fatehgarh-2 sites | Auxiliary Switch (The site-wise quantity details shall be as per Annexure-II) | 4 | No | 152 |
| 75 | 72.5 kV DBR, 1250 Ampere at Bhadla-2, Fatehgarh-2 sites of NWR region POWERGRID | Overload Relay WITH CONTACTOR (The site-wise quantity details shall be as per Annexure-II) | 4 | No | 152 |
| 76 | 72.5 kV DBR, 1250 Ampere at Bhadla-2, Fatehgarh-2 sites of POWERGRID | 3 Pole ON- OFF Rotary Switch (The site-wise quantity details shall be as per Annexure-II) | 4 | No | 152 |
| 77 | 72.5 kV DBR, 1250 Ampere at Bhadla-2, Fatehgarh-2, Bikaner | Motor (The site-wise quantity details shall be as per Annexure-II) | 5 | No | 152 |
| 78 | 72.5 kV DBR, 1250 Ampere at Bhadla-2, Fatehgarh-2 sites, POWERGRID | PUSH Button ON (The site-wise quantity details shall be as per Annexure-II) | 4 | No | 152 |
| 79 | 72.5 kV DBR, 1250 Ampere at Bhadla-2, Fatehgarh-2, POWERGRID | PUSH Button OFF (The site-wise quantity details shall be as per Annexure-II) | 4 | No | 152 |
| 80 | 72.5 kV DBR, 1250 Ampere at Bhadla-2, Fatehgarh-2, NWR region | PUSH Button Manual (The site-wise quantity details shall be as per Annexure-II) | 4 | No | 152 |
| 81 | 72.5 kV DBR, 1250 Ampere at Bhadla-2, Fatehgarh-2, NWR region,POWERGRID | PUSH Button Stop (The site-wise quantity details shall be as per Annexure-II) | 4 | No | 152 |
| 82 | 72.5 kV DBR, 1250 Ampere at Bhadla-2, Fatehgarh-2, Bikaner of NWR region | MOM BOX (The site-wise quantity details shall be as per Annexure-II) | 5 | No | 152 |
| 83 | 72.5 kV DBR, 1250 Ampere at Bhadla-2, Fatehgarh-2, NWR, POWERGRID | DOWN PIPE ( From MOM Box to Isolator ) (The site-wise quantity details shall be as per Annexure-II) | 4 | No | 152 |
| 84 | 72.5 kV DBR, 1250 Ampere at Bhadla-2, Fatehgarh-2, Bikaner of NWR | MALE Copper Blades ( set ) (The site-wise quantity details shall be as per Annexure-II) | 6 | No | 152 |
| 85 | 72.5 kV DBR, 1250 Ampere at Bhadla-2, Fatehgarh-2, Bikaner of NWR region POWERGRID | FEMALE Copper Fingers ( set ) (The site-wise quantity details shall be as per Annexure-II) | 6 | No | 152 |
| 86 | 72.5 kV DBR, 1250 Ampere at Bhadla-2, Fatehgarh-2, Bikaner sites of NWR region | Isolator Moving Arms (Moving Contact Assembly (Per No)) (The site-wise quantity details shall be as per Annexure-II) | 6 | No | 152 |