Supply Lowering Assembling and Fixing in Position Tender - 152413118

INDIAN ARMY has floated a tender for Supply Lowering Assembling and Fixing in Position 250 Mm Dia Outside Dia 272.20 Mm and Wall Thickne, Qty: 1960. The project location is Bardhaman, West Bengal, India. The reference number is - and it is closing on 23 Nov 2026. Suppliers can request Register free of cost to get the complete Tender details and download the document.

Procurement Summary

State: West Bengal

Summary: Supply Lowering Assembling and Fixing in Position 250 Mm Dia Outside Dia 272.20 Mm and Wall Thickne, Qty: 1960

Deadline: 23 Nov 2026

Posting Date: 13 Nov 2026

Other Information

Notice Type: Tender

TOT Ref.No.: 152413118

Document Ref. No.: Login to see detail

Financier: Self Financed

Purchaser Ownership: Public

Document Fees: Refer Document

Tender Value: Refer Document

EMD: Refer Document

Purchaser's Detail

Name: Login to see details

Address: Login to see details

Email: Login to see details

  Login to see details

Tender Details

Descrption: Login to see details

IMP: Login to see details

Contact Details: Login to see details  Login to see details

Documents

 Tender Notice

Bid_Document_10137700.pdf

Specification_Document.pdf

BOQ_Document.csv

Bill of Quantities (BOQ)

# Title Description Qty Unit Delivery (Days)
1 Supply lowering assembling and fixing in position 250 mm dia Outside dia 272.20 mm and wall thickness 15.1 mm complete including jointing of pipes with proper jointing materials Supply lowering assembling and fixing in position 250 mm dia PVC threaded pipes conform to ASTMD1785 having inside dia 250 mm Outside dia 272.20 mm and wall thickness 15.1 mm complete including jointing of pipes with proper jointing materials as per IS in randam pipe length of 3 meter including necessary fittings as required at site and necessary testing all as specified and directed by EngrinCharge. 60 RM 90
2 Supply lowering assembling and fixing in position 200 mm dia Outside dia 218.70 mm and wall thickness 12.7 mm complete of pipes with proper jointing materials Supply lowering assembling and fixing in position 200 mm dia PVC threaded pipes conform to ASTMD1785 having inside dia 200 mm Outside dia 218.70 mm and wall thickness 12.7 mm complete including jointing of pipes with proper jointing materials as per IS in randam pipe length of 3 meter including necessary fittings as required at site and necessary testing all as specified and directed by EngrinCharge. 60 RM 90
3 Supply lowering assembling and fixing in position 200 mm dia PVC M F Sq threaded ribbed creen casing Strainer pipeline screen having slot size 0.5 to 0.75 mm confirming to ISI128181 Supply lowering assembling and fixing in position 200 mm dia PVC M F Sq threaded ribbed creen casing Strainer pipeline screen having slot size 0.5 to 0.75 mm confirming to ISI128181 complete all as specified and directed. 40 RM 90
4 Supplying and fixing in position of M F Adopter of suitable size complete all as specified and directed. Supplying and fixing in position of M F Adopter of suitable size complete all as specified and directed. 2 Each Set 90
5 Drilling of trial bore hole by Direct Rotary Rig Method Hydraulic rotary drilling disposal of spoil from the site for a depth upto 200 metes from ground level complete all as specified and directed. Drilling of trial bore hole by Direct Rotary Rig Method Hydraulic rotary drilling Reverse Circulation Method according to IS.28001991 PartI as amended upto date and modified to extent of specifiecation attached with this schedule of items of works in all kinds of soils and boulders upto 300 mm dia the cost of all consumable stores fuel oil soil stabilising material arrangement and transportation of rig and other accessories to site of proposed bore and back including disposal of spoil from the site for a depth upto 200 metes from ground level complete all as specified and directed. Note i The quoted rate shall deemed to be inclusive of the cost of drilling rig pumps fittings etc which shall be provided by the Contractor under his own arrangement for execution of the work . 200 RM 90
6 Supplying and fixing in position mild steel well cap of MS plate 8 mm thick with an internal threading and locking arrangement having opening for column pipe and submersible cable of 250 mm dia Supplying and fixing in position mild steel well cap of MS plate 8 mm thick with an internal threading and locking arrangement having opening for column pipe and submersible cable of 250 mm dia internal housing PVC pipe and centre guide bail plug reducing socket and and necessary welding work as required at site for completion of the job complete all as specified and directed. Note i Rate quoted is deemed to be included for Necessary MS work required to be fixed well cap in position as directed at site as by Engrincharge. ii After completion of the work the cap will be used to keep the tube well closed untill the pump set is installed . 1 Each Job 90
7 Yield testing for the tube well by suitable capacity submersible pump and motor for minimum dischraging capacity of 10000 gallons per hours for at least continuous 24 hours uninterrupted run per day Yield testing for the tube well by suitable capacity submersible pump and motor for minimum dischraging capacity of 10000 gallons per hours for at least continuous 24 hours uninterrupted run per day for the continuous days compete all as specified and directed. 1 Each Job 90
8 Development of tube9.3 air compressor of capacity 350 PSI 1000 Cum till sand 10000 GPH complete all as specified and directed. Development of tube well according to clause 9.3 of IS28001991 . partI as amended upto date and specificatios attached with air compressor of capacity 350 PSI 1000 Cum till sand mud free water of potable quality is obtained and to achieve minimum discharging capacity of 10000 GPH complete all as specified and directed. Note Compressor with accessories and fuel pipes etc shall be arranged by the Contractor and quoted rate is deemed to be included in item 72 Per Hours 90
9 Testing of raw and treated water 02 samples Raw and treated water for all parameters covering complete Chemical and Bacteriological Testing of raw and treated water 02 samples Raw and treated water for all parameters covering complete Chemical and Bacteriological aspect from any Govt accredited NABL certified lab as approved by the GE complete all as specified. 2 Each Job 90
10 Electrologing test with using suitable equipments lowering of agency Govt firm and report shall be submitted to GE for approval complete all as specified and as directed. Electrologing test with using suitable equipments for the bore hole before sinking lowering of pipes filters etc for arresting proper deliniation of water from Govt reconised agency Govt firm and report shall be submitted to GE EngineerinCharge for approval complete all as specified and as directed. Note i Procurement action of borewell items like submersible pump and motor submersible cable column pipe and other misc accessories required to be installed after borwell will only be considered by Contractor after submission of Electrologing Test report to GE EIC and further instruction from the department will be binding and final . 1 Each Job 90
11 Supply and filling pea gravel of size 2 to 4 mm for packing around the housing assembly slotted pipe of the bore well complete all as specified and directed. Supply and filling pea gravel of size 2 to 4 mm for packing around the housing assembly slotted pipe of the bore well complete all as specified and directed. Note Pea gravel shall be paid as per stack measurement carried out on site . 26 CUM 90
12 Supplying lowering fixing commissioning and testing submersible pumping set with pump and motor in borewell electrically driven 415 Volts three phase AC all as specified and directed. Supplying lowering fixing commissioning and testing submersible pumping set with pump and motor in borewell electrically driven 415 Volts three phase AC having a min discharge capacity 55 Cum Hour at a head o fmin 80 meters 10 to 12 stage delivery discharge dia 100 mm inclujding insertion of GI ERW column pipe with other connected accessories and necessary electrical connections complete all as specified and directed. Note GI column pipe pipe accessories and submersible cable shall be measured and paid seperately . 1 Each Job 90
13 M and L for steel wire rope 12 mm galvanised IWRC suitable size clamps and U bolts for holding the submersible pumps and motor of capcity uto 35 HP as specified and directed. M and L for steel wire rope 12 mm alongwith suitable size clamps U submersible pumps and motor of capcity uto 35 HP complete all as specified and directed. 85 RM 90
14 Supply and laying PVC insulated and PVC sheathed industrial cable for Submersible pump motors of size 16 Sqmm flat three core copper conductor 1100 Volts as specified and directed. Supply and laying PVC insulated and PVC sheathed industrial cable for Submersible pump motors of size 16 Sqmm flat three core copper conductor 1100 Volts Confirming to IS694 complete all as specified and directed. 90 RM 90
15 Supply and laying ERW MS pipe Heavy duty with welded GI flange pipe 3 Meter Long both side MS flange 100 mm dia ISI specified and directed. Supply and laying ERW MS pipe Heavy duty with welded GI flange For Column pipe 3 Meter Long both side MS flange 100 mm dia ISI marked with all tube fittings complete with all fittings required for column pipe lowering like suitable size nuts bolts and heavy duty washers and including cutting pipes screwing wash and for making gorged bends on piping complete all as specified and directed. Make pipe Jindal Tata Note Necessary nuts bolts washers and rubber washer sheet required for jointing of column pipe every after 3 meter length is deemed to be included in quoted rate . 12 Each 90
16 Supply and fixing of Double Flanged non rising Rising Spindle Sluice Valve 150 MM of PN 1.6 as per IS 14846 as specified and directed. Supply and fixing of Double Flanged non rising Rising Spindle Sluice Valve 150 MM of PN 1.6 as per IS 14846 and IS1538 cast iron as per IS210 Gr FG260 SS spindle Bronze body seat ring Bornze wedge ring gland packingjute and hemp Natural rubber gasket Bornze stem nut with spining wheel complete all as directed. 5 Each 90
17 Supply and fixing of Non return sulice valve 150 mm bore confirming to IS5312 PartI pressure rating PN1.6 as specified and directed. Supply and fixing of Non return sulice valve 150 mm bore confirming to IS5312 PartI pressure rating PN1.6 Flange drilling as per IS1538 CI valve body diaphragm CI disc Disc face ring rubber Aluminium hinge pin CI hinge and bornze body ring complete all as directed. 1 Each 90
18 Supply laying and testing of ductile iron pipes blue black colour of size 150mm bore complete all as specified and directed. Supply laying and testing of ductile iron pipes blue black colour of size 150mm bore with spigot and socket ends Flanged end push on rubber joint Bolted joint centrifugally cast class K7 in any length laid in trenches on surface over masonry pillar and connection to old or new position of including push on rubber EPDM ring complete all as specified and directed. Note. i Rubber ring gasket joint jointing materials etc required for jointing of DI pipes shall deemed to be included in unit rate. ii Excavation and earth work shall be measured and paid separately . 180 RM 90
19 Supply laying and testing of iron pipes blue black colour of size 100mm bore K7 in any length laid in trenches complete all as specified and directed. Supply laying and testing of ductile iron pipes blue black colour of size 100mm bore with spigot and socket ends Flanged end push on rubber joint Bolted joint centrifugally cast class K7 in any length laid in trenches on surface over masonry pillar and connection to old or new position of including push on rubber EPDM ring complete all as specified and directed. Note. i Rubber ring gasket joint jointing materials etc required for jointing of DI pipes shall deemed to be included in unit rate. ii Excavation and earth work shall be measured and paid separately . 72 RM 90
20 M and L for D I fitting for flanged pipe such bend any type radius and angle taper any type straight bends increasing decreasing or double socket etc. for 150 mm bore DI pipe. M and L for D I specials fitting for flanged pipe such bend any type radius and angle taper any type straight bends increasing decreasing or double socket etc. for 150 mm bore DI pipe. 350 KG 90
21 Construction of valve pit chamber with brick masonary with sub class B bricks one brick thick in cement mortar 1.6 and necessary PCC 75mm thick type D2 1.4.8 as in foundation and 15mm thick Construction of valve pit chamber with brick masonary with sub class B bricks one brick thick in cement mortar 1.6 and necessary PCC 75mm thick type D2 1.4.8 as in foundation and 15mm thick plastering on brick work in cement mortar 1.4 k having internal dimension 150cm x 150cm x 120cm and providing of 3mm thick MS sheet cover duly hinged on 40mm x 40mm x 6mm angle Necessary all as specified and directed. 3 Each 90
22 M and L Cutting in position of 150mm pipe inserting new tee pof 150x150x150 mm and jointing including with necessary jointing materials complete all as specified. M and L Cutting in position of 150mm pipe inserting new tee pof 150x150x150 mm and jointing including with necessary jointing materials complete all as specified. 1 Job 90
23 MandL for XLPE insulated LT armoured electric cable with aluminium stranded conductor 1100 volts grade crosssectional area 70 sqmm 3.5 core as specified and directed. MandL for XLPE insulated LT armoured electric cable with aluminium stranded conductor 1100 volts grade crosssectional area 70 sqmm 3.5 core laid in trenches pipes ducts wall borings with necessary cable lugs and glands nuts bolts and washers etc and testing complete all as specified and directed. NOTE. Excavation earth work sand cushioning cable cover brick shall be measured and paid separately if required 200 RM 90
24 Excavation in trenches soft soil not exceeding 1.5 mtr wide in not exceeding 1.5mtr in depth for foundation etc as specified and directed. MandL for earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directly in ground vertically earth pit not less than 2.25 meters deep below ground level with top edge of plate not less than 1.5 metres below ground level connected to and includingGI Strip of size 32x6mm and light grade protection pipe of 40 mm dia from earth electrode up to test point or up to 7.5mtr whichever is less by means of GI bolts nuts check nuts and washers all as per electrical plate No 3 of SSR PtI and GI watering pipe of 20 mm dia medium grade GI funnel with wire mesh including charcoal salt packed all around the earth electrode plate in layers PCC earth pit chamber 1.3.6 type C1 of size 45X 45X 45 CM RCC cover 1.2.4 type B1 of size 45X45X6 CM excavation earth work in any strata and returning filling removal of surplus soil and testing test point for required value including removing old item complete all as specified and directed. GI strip upto 7.5m including testing consider in this item . 2 Each Set 90
25 Supply installing testing and commissioning LT Outdoor type Double door SIZE 1200MMX1000MMX500MM hxwxd suitable for 415 Volts 3 4 wire 50Hz AC Supply installing testing and commissioning factory made and tested LT Outdoor type Double door SIZE 1200MMX1000MMX500MM hxwxd platform mounted suitable for 415 Volts 3 Phase and neutral 4 wire 50Hz AC supply system having bus bar chamber with insulated electrolytic Aluminium bus bars of 250 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof protection class IP65 and made of 3.00 mm thick CRCA mild steel sheet and mild steel angle iron frame work made out of 50 mm x 50 mm x 6 mm thick size but not less than 1.5 sqmm complete <br> 1 Job 90
26 Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cm complete all as specified and as directed Excavation in trenches soft loose soil not exceeding 1.5 mtr wide in not exceeding 1.5mtr in depth for foundation etc or for shaft well cesspits manholes fire hole etc n.exc 10sqmm on plan and not exceeding 1.5mtr in depth and getting out complete all as specified and as directed by the EngineerInCharge 127 CUM 90
27 Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cm complete all as specified and as directed Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cm complete all as specified and as directed by the EngineerInCharge 98 CUM 90
28 Removing excavated material not exceeding 50mtr and depositing where directed at a level not exceeding 1.5mtr above the starting point complete all as specified and as directed Removing excavated material not exceeding 50mtr and depositing where directed at a level not exceeding 1.5mtr above the starting point complete all as specified and as directed by the EngineerInCharge 29 CUM 90
29 Boring holes horizontally under Road without damaging the surface of road minimum 1.0 Mtr bellow the road surface with the help of GI tubing as specified and as directed Boring holes horizontally under Road without damaging the surface of road minimum 1.0 Mtr bellow the road surface with the help of GI tubing of any dia not exc 100 mm dia for passing of UG cable all as specified and as directed. GI Pipe laid shall be measured seperately 20 RM 90
30 MandL for sand cushioning in trenches for protection of LT under ground cable including watering and consolidation. MandL for sand cushioning in trenches for protection of LT under ground cable including watering and consolidation. 15 CUM 90
31 Supplying and laying common burnt bricks clay building sub class B desingation 75 in trenches for cable protection complete all as directed. Supplying and laying common burnt bricks clay building sub class Bdesingation 75 in trenches for cable protection complete all as directed. 2 Each 90
32 M and L brickwork with subclass Bbricks straight or curved on plan exc 6M mean radious built in cement mortar 1.6 complete all as directed. M and L brickwork with subclass B bricks straight or curved on plan exc 6M mean radious built in cement mortar 1.6 complete all as directed. 2 CUM 90
33 M and L Rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement plaster 1.6 complete all as specified. M and L Rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement plaster 1.6 complete all as specified. 20 SQM 90
34 M and L for white washing on walls complete on undecoraed surfaces with two coats all as specified M and L for white washing on walls complete on undecoraed surfaces with two coats all as specified 20 SQM 90
35 Material and labour for GI pipe 50 mm light gradelaid in trenches floors on pole road for cable protection with all fittings complete all as specified and directed . Material and labour for GI pipe 50 mm light grad laid in trenches floors on pole road for cable protection with all fittings complete all as specified and directed . 20 RM 90
36 Material and Labour for hard core of broken bricks gauge exc. 63 mm but not exc.100 mm deposited spread and leveled in layers 100 mm thick and well rammed complete all as specified and as directed. Material and Labour for hard core of broken bricks gauge exc. 63 mm but not exc.100 mm deposited spread and leveled in layers 100 mm thick and well rammed complete all as specified and as directed. 4 CUM 90
37 Material and Labour for proper borewell sealing to prevent migration of surfacethe well with PCC sanitary sealing of 75 mm thick using 20 mm graded aggregate Material and Labour for proper borewell sealing to prevent migration of surface water into the intake aquifer and neat cement grout near the top of the well with PCC sanitary sealing of 75 mm thick 1.2.4 type B1 using 20 mm graded aggregate complete all as specified and as directed. 20 SQM 90
38 M and L for Cement concrete in foundations fillings and mass concrete type C2 1.3.6 40 mm graded aggregagte M and L for Cement concrete in foundations fillings and mass concrete type C2 1.3.6 40 mm graded aggregagte 3 CUM 90
39 MandL for Resistivity test to be carried out by Geological Department and report to be submitted before drilling the bore well complete all as specified and as directed MandL for Resistivity test to be carried out by Geological Department and report to be submitted before drilling the bore well complete all as specified and as directed Note. i Before drilling the bore contractor has to carry out site survey and electrical resistivity test survey for groung waer exploration to be carried out of minimun 5 points for each borewell in and around said locations in area to obtain max groung water potential and report of the same has to be submitted to Ge for taking approval of site point withmaximum water potential for boring. ii All necessary arrangement test survey done by the contractor and cost for same to be included in unit rate. No extra charge will be paid by the contractor. 1 Job 90
40 M and L for cement sealing with PCC 1.2.4 type TypeB0 12.5mm graded aggregate effective of 3 meter thickness depth range of M and L for cement sealing with PCC 1.2.4 type TypeB0 12.5mm graded <br>aggregate for fresh water aquifers effective of 3 meter thickness on the borewell within the depth range 70 to 100 meters immediatel pipe and given rest for 72 hrs for prevention of entering contaminated ground water to the borewell all as directed by GE EIC. 2 CUM 90
41 Surfacing dressing n exc 15 cm deep in soft loose soil. Surfacing dressing n exc 15 cm deep in soft loose soil. 50 Sqm 90
42 MandL for hardcore of broken brick n exc 63mm laid rammed in floor. MandL for hardcore of broken brick n exc 63mm laid rammed in floor. 4 CUM 90
43 MandL for PCC 75mm thick type D2 1.4.8 as in sub base preparing the surface for flooring MandL for PCC 75mm thick type D2 1.4.8 as in sub base preparing the surface for flooring 50 Sqm 90

Corresponding Contract Award Notice

No Contract Award Notice found for this tender. Please try using the Contract Award Search Page.


Request Demo