1 |
Supply Installation commissioning of deep freezer minimum 350Lcapacity Glass top 5 star electric driven single phase 240V 50HZ . complete all as specified as directed. |
Supply Installation .commissioning of deep freezer minimum 350Lcapacity Glass top 5 star electric driven single phase 240V 50HZ . complete all as specified and as directed. |
3 |
Each |
150 |
|
2 |
ML for sub main wiring with two single core 6 sq mm insulated unsheathed stranded copper conductor cable |
ML for sub main wiring with two single core 6 sq mm FRLSH PVC insulated unsheathed stranded copper conductor cable drawn through in any type of massinory including 25 mm dia non metallic PVC conduit fixed in wall including 6 sq mm copper earth continuity wire accessories and connecting to earth dolly complete all as specified and as directed by EIC. |
70 |
RM |
150 |
|
3 |
ML for sub main wiring with two single core 4 sq mm insulated unsheathed stranded copper conductor cable |
ML for sub main wiring with two single core 4 sq mm FRLSH PVC insulated unsheathed stranded copper conductor cable drawn through in any type of massinory including 25 mm dia non metallic PVC conduit fixed in wall including 4 sq mm copper earth continuity wire accessories and connecting to earth dolly complete all as specified and as directed by EIC. |
106 |
RM |
150 |
|
4 |
Supply fixing Window AC of capacity 1.5 Ton AC 5 star 230v 50 Hz inverter type Copper tubes including cutting of wall as specified as directed. |
Supply fixing Window AC of capacity 1.5 Ton AC 5 star 230v 50 Hz inverter type Copper tubes including cutting of wall bracket stand of appropriate size complete all as specified and as directed. |
4 |
Each |
150 |
|
5 |
S F MCB SPN 32 Amps 240 volts and out going electric connection with suitable size of copper lugs |
S F MCB SPN 32 Amps 240 volts 50 Hz curve including necessary incoming and outgoing electric connection with suitable size of copper lugs all as specified and as directed by Engor in Charge |
4 |
Each |
150 |
|
6 |
S F sheet metal enclosures with socket plug top single pole with a with one single pole MCB of 20 Amps 240 |
S F sheet metal enclosures with socket plug top single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps 240 Volts all as specified and as directed by EIC. |
7 |
Each |
150 |
|
7 |
Supply and fix Single Phase Voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170 Volts to 300 Volts |
Supply and fix Single Phase Voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170 Volts to 300 Volts with output voltage satbilized at 230 Volts with accuracy of plus Minus 2.5% of 4 KVA rating complete |
4 |
Each |
150 |
|
8 |
Supply and fix Single Phase Voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170 Volts to 300 Volts |
Supply and fix Single Phase Voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170 Volts to 300 Volts with output voltage satbilized at 230 Volts with accuracy of plus Minus 2.5% of 2 KVA rating complete |
3 |
Each |
150 |
|
9 |
S F sheet metal enclosures for SPN DBs with double door for incorporating MCBs IP 43 4 way with 200 amps |
S F sheet metal enclosures for with double door for incorporating MCBs IP 43 4 way with 200 amps rated busbar 240 volts as per surface complete all as specified and as directed all as specified and as directed. |
3 |
Each |
150 |
|
10 |
S F sheet metal enclosures for SPN DBs with double door for incorporating MCBs IP 43 8 way with 200 amps |
S F sheet metal enclosures for with double door for incorporating MCBs IP 43 8 way with 200 amps rated busbar 240 volts as per IS 8623 and existing surface complete all as specified and as directed all as specified and as directed. |
1 |
Each |
150 |
|
11 |
S F MCB SP 6 to 32 Amps B Curve 240 volts 50 Hz including making necessary incoming and out going electric connection with suitable size of copper lugs |
S F MCB SP 6 to 32 Amps B Curve 240 volts 50 Hz including making necessary incoming and out going electric connection with suitable size of copper lugs and testing all as specified and as directed by Engr in Charge. |
12 |
Each |
150 |