1 |
Conventional vertical air terminal Franklin rod |
Vertical Electrolytic copper air terminal minimum 25.4 mm (1 inch) diameter and 1000 mm length copper purity minimum 90 per |
2 |
Nos |
30 |
|
2 |
FRP supporting pole |
Non metallic fiberglass reinforced plastic pole for holding the conventional air terminal with mounting accessories and structural couplings |
2 |
Nos |
30 |
|
3 |
GI support pole with base plate |
Hot dip galvanized iron pipe with welded structural base plate heavy duty structural clamps and all mounting accessories to support FRP pole |
2 |
Nos |
30 |
|
4 |
Copper strip |
Copper strip 25 mm width X 3 mm thickness copper purity minimum 90 percent |
20 |
Mtr |
30 |
|
5 |
Copper wire lugs |
Copper lugs suitable for 50 mm square conductor copper purity minimum 90 percent |
8 |
Nos |
30 |
|
6 |
Stainless steel guy wire multi strand |
Corrosion free stainless-steel guy wire Diameter 6mm with all mounting connecting accessories and assemblies for supporting FRP GI pipes |
300 |
Mtr |
30 |
|
7 |
Bulldog grips for guy wire |
Corrosion free stainless steel grips suitable for holding 5 10 mm guy wire |
50 |
Nos |
30 |
|
8 |
D shackle |
Corrosion free stainless steel 8 mm |
12 |
Nos |
30 |
|
9 |
Straightening screw eye hook |
Corrosion-free stainless-steel, 10 mm. |
12 |
Nos |
30 |
|
10 |
Anchor rod for guy wire and associated accessories |
M20, complete with associated accessories as required. |
12 |
Nos |
30 |
|
11 |
Foundation bolts for GI pipe base and associated accessories |
M16, complete with nuts, washers and accessories. |
6 |
Nos |
30 |
|
12 |
Dismantling of existing Advanced Lightning Protection System ALPS |
Dismantling removal of one existing advanced lightning protection system including associated mounting hardware conductors and accessories without affecting Radar operations removal and handling as directed by AAI |
1 |
Job |
45 |
|
13 |
Down conductor |
PVC insulated flexible copper cable minimum 50 mm square crosssectional area copper purity minimum 90 perc |
130 |
Mtr |
30 |
|
14 |
Digital lightning strike counter transient event counter |
Digital impulse current counter sensitive to minimum 250 A (8 20 micro sec) maximum discharge current 200 kA (10 350 micro sec ) count up to 999 occurrences |
2 |
Nos |
30 |
|
15 |
Complete installation, testing and commissioning of Conventional Lightning Protection System |
Complete installation, testing and commissioning of Conventional Lightning Protection System with above items Total Project timeline 45 Days (Supply 30 Days, Installation, Testing Commissioning 15 Days) |
2 |
Job |
45 |