Single Loop Analogue Addressable Fire Alarm Control Panel FACP |
Microprocessor controlled analogue addressable single loop fire alarm control panel housed in a heavy duty Sheet Steel or certified high impact Flame Retardant FR enclosure meeting a minimum IP30 ingress protection classification Features a minimum 40x4 character alphanumeric LCD or high resolution graphical touchscreen equivalent with diagnostic status LEDs and a tactile touch keypad The architecture must natively support at least 159 loop addressable devices minimum allocation profile 127 combinations of detectors modules and 32 loop sounders or a structurally equivalent manufacturer protocol configuration layout Configurable for Class A or Class B loop wiring topologies with integrated loop short circuit isolation capabilities conforming to IS 2189 loop integrity mandates Built in USB 20 interface for site configuration mapping and data backup with an onboard RS 485 communication port for multi repeater networking Equipped with at least 2 programmable potential free Form C relays Fire Pre Alarm Supervisory and 1 dedicated Fault relay Compliance Independently certified as meeting the requirements of EN 54 Part 2 and Part 4 or UL 864 equivalent and fully conforming to the statutory system selection and installation criteria of IS 2189 2026 |
1 |
Nos |
90 |
|
2 |
Analogue Addressable Photoelectric Smoke Detector with Base |
Analogue Addressable Photoelectric Smoke Detector SITC of Addressable Smoke Detector with base with Binary coded address setting Dual LEDs for 360 degree visibility Sleek low profile housing design Regular 100mm base IP Rating IP 42 Approval UL Listed 94Nos for installation and 3 spare making a Total of 97Nos |
97 |
No |
90 |
|
3 |
Loop Powered Sounder |
Loop Powered Sounder SITC of Loop Powered Sounder with audible level 90db at 1Mtr ABS Plastic Material including back box Approval CE Mark 5Nos for installation and 1spare making a Total of 06Nos |
6 |
No |
90 |
|
4 |
Analogue Addressable Manual Call Point |
Analogue Addressable Manual Call Point SITC of Addressable Manual Call Point Resettable type with back box with binary coded address setting with status LED for 360 degree visibility IP 50 5Nos for installation and 1spare making a Total of 6Nos |
6 |
No |
90 |
|
5 |
Response Indicator |
Response Indicator SITC of Response Indicator 46Nos for installation and 5spare making a Total of 51Nos |
51 |
No |
90 |
|
6 |
2 Core x 15 Sq mm |
2 Core x 15 Sq mm Shielded Twisted Pair Armoured Fire Survival FS or Fire Resistant FR copper signaling cable conforming to IS 17505 Part 1 or IEC 60331 |
1050 |
Meter |
90 |
|
7 |
Heavy duty rigid 25mm OD FRLS Flame Retardant Low Smoke or LSZH Low Smoke Zero Halogen rigid PVC conduits |
Heavy duty rigid 25mm OD FRLS Flame Retardant Low Smoke or LSZH Low Smoke Zero Halogen rigid PVC conduits conforming to IS 9537 Part 3 complete with FRLS inspection bends and structural junction boxes |
800 |
Meter |
90 |
|
8 |
Cable laying charges |
Cable laying charges through 25mm PVC pipes including fixation of pipe by SS screw and clamp in Deep Bhavan building on wall under POP wall and laying of cable including excavation and filling as per direction given by engineer incharge |
1050 |
Meters |
90 |
|
9 |
Installation of Smoke Detectors MCP Manual Call Point Hooters and Response indicators by skilled electrical team |
Installation of Smoke Detectors MCP Manual Call Point Hooters and Response indicators by skilled electrical team |
150 |
Nos |
90 |
|
10 |
Addressable Control Fire Alarm Panel installation configuration and testing charges |
Addressable Control Fire Alarm Panel installation configuration and testing charges |
1 |
Job |
90 |
|
11 |
12V 9AH or 7AH SMF VRLA batteries designated for internal installation inside the FACP chassis |
Supply and installation of 12V 9AH or 7AH SMF VRLA batteries designated for internal installation inside the FACP chassis to serve as primary system standby power |
2 |
Nos |
90 |
|
12 |
2KVA True Online Double Conversion |
Supply and installation of 2KVA True Online Double Conversion UPS providing a Pure Sine Wave output profile 0ms transfer time complete with an external battery bank designed to provide a continuous autonomous backup runtime of more than 1 hour at operational system loads |
1 |
Nos |
90 |
|
13 |
Wall mount 12U industrial equipment cabinet with an extended depth of 600mm |
Supply and installation of Wall mount 12U industrial equipment cabinet with an extended depth of 600mm heavy duty load bearing internal shelf and integrated dual cooling fan facility to house the 2KVA UPS system and battery bank safely |
1 |
Nos |
90 |
|
14 |
Patching and repairing of false ceiling and painting by high quality white emulsion paint for complete building during installation work |
Patching and repairing of false ceiling and painting by high quality white emulsion paint for complete building during installation work |
1 |
LS |
90 |