OIL FILLED SERVICE TRANSFORMER FOR SCCL SINGRENI Tender - 151261727

BHARAT HEAVY ELECTRICALS LIMITED (BHEL) has floated a tender for OIL FILLED SERVICE TRANSFORMER FOR SCCL SINGRENI PROJECT, Qty: 24. The project location is Adilabad, Telangana, India. The reference number is GEM/2026/B/8175909 and it is closing on 05 Nov 2026. Suppliers can request Register free of cost to get the complete Tender details and download the document.

Expired Tender

Procurement Summary

State: Telangana

Summary: OIL FILLED SERVICE TRANSFORMER FOR SCCL SINGRENI PROJECT, Qty: 24

Deadline: 05 Nov 2026

Posting Date: 21 Oct 2026

Other Information

Notice Type: Tender

TOT Ref.No.: 151261727

Document Ref. No.: GEM/2026/B/8175909

Financier: Self Financed

Purchaser Ownership: Public

Document Fees: Refer Document

Tender Value: Refer Document

EMD: Refer Document

Purchaser's Detail

Name: Login to see tender_details

Address: Login to see tender_details

Email: Login to see tender_details

Login to see details

Tender Details

PART-A, 630 KVA, 11kV 0.433kV, 3 phase, 2 winding, outdoor, ONAN, please refer BOQ and technical specification uplodaed for details, PART-A, 2000kVA, 11kV 0.433kV, 3 phase, 2 winding, outdoor, ONAN, please refer BOQ and technical specification uplodaed for details, PART-A, 2500kVA, 11kV 0.433kV, 3 phase, 2 winding, outdoor, ONAN, please refer BOQ and technical specification uplodaed for details, PART-A, TYPE TEST FOR 630 KVA, 11kV 0.433kV Transformers Details as per Annexure-I PART- A S. No. 1, PART-A, TYPE TEST FOR 2000 KVA, 11kV 0.433kV Transformers Details as per Annexure-I PART-A S. No. 2, PART-A, TYPE TEST FOR 2500 KVA, 11kV 0.433kV Transformers Details as per Annexure-I PART-A S. No. 3, PART-A, EXTRA OIL 5 PERCENT FOR 630 KVA TRANSFORMERS, PART-A, EXTRA OIL 5 PERCENT FOR 2000 KVA TRANSFORMERS, PART-A, EXTRA OIL 5 PERCENT FOR 2500 KVA TRANSFORMERS, PART-A, Mandatory Spares for 630 KVA Transformers, refer BOQ Annexure-II for details, attached with specification, PART-A, Mandatory Spares for 2000 KVA Transformers, refer BOQ Annexure-II for details, attached with specification, PART-A, Mandatory Spares for 2500 KVA Transformers, refer BOQ Annexure-II for details, attached with specification, PART-B, 16 MVA, 11kV 3.45kV, 3 phase, 2 winding, outdoor, ONAN, please refer BOQ and technical specification uplodaed for details, PART-B, TYPE TEST FOR 16 MVA, 11kV 3.45kV Transformers, Details as per Annexure-I PART-B S. No. 1, PART-B, EXTRA OIL 5 PERCENT FOR 16 MVA TRAN...

Oil Filled Service Transformer for Sccl Singreni Project
Quantity Required: 24

Start Date: 21-10-2026 9:37 AM

End Date: 05-11-2026 3:00 PM

BOQ Title: OIL FILLED SERVICE TRANSFORMER FOR SCCL SINGRENI PROJECT

Relevant Categories: Control Transformer Distribution Transformer, 3 Phase, 11 kV, 200 KVA upto and Including 2500 KVA I...

GeMARPTS Searched: Control Transformer, Distribution Transformer, 3 Phase, 11 kV, 200 KVA upto and Including 2500 KVA ISI Marked To IS 1180 (Part 1), Isolation Transformer, Distribution Transformer, 3 Phase, upto and Including 200 KVA ISI Marked To IS 1180 (Part 1), Transformer Oil Pump, Transformer Oil BDV Test Kit, ...
Tender ID: GEM/2026/B/8175909

Documents

 Tender Notice

Bid_Document_10052220.pdf

Specification_Document.pdf

BOQ_Document.csv

Bill of Quantities (BOQ)

# Title Description Qty Unit Delivery (Days)
1 PART-A, 630 KVA, 11kV 0.433kV, 3 phase, 2 winding, outdoor, ONAN, please refer BOQ and technical specification uplodaed for details PART-A, 630 KVA, 11kV 0.433kV, 3 phase, 2 winding, outdoor, ONAN, please refer BOQ and technical specification uplodaed for details 2 Nos 340
2 PART-A, 2000kVA, 11kV 0.433kV, 3 phase, 2 winding, outdoor, ONAN, please refer BOQ and technical specification uplodaed for details PART-A, 2000kVA, 11kV 0.433kV, 3 phase, 2 winding, outdoor, ONAN, please refer BOQ and technical specification uplodaed for details 6 Nos 340
3 PART-A, 2500kVA, 11kV 0.433kV, 3 phase, 2 winding, outdoor, ONAN, please refer BOQ and technical specification uplodaed for details PART-A, 2500kVA, 11kV 0.433kV, 3 phase, 2 winding, outdoor, ONAN, please refer BOQ and technical specification uplodaed for details 2 Nos 340
4 PART-A, TYPE TEST FOR 630 KVA, 11kV 0.433kV Transformers Details as per Annexure-I PART-A S. No. 1 PART-A, TYPE TEST FOR 630 KVA, 11kV 0.433kV Transformers Details as per Annexure-I PART-A S. No. 1 1 Lot 340
5 PART-A, TYPE TEST FOR 2000 KVA, 11kV 0.433kV Transformers Details as per Annexure-I PART-A S. No. 2 PART-A, TYPE TEST FOR 2000 KVA, 11kV 0.433kV Transformers Details as per Annexure-I PART-A S. No. 2 1 Lot 340
6 PART-A, TYPE TEST FOR 2500 KVA, 11kV 0.433kV Transformers Details as per Annexure-I PART-A S. No. 3 PART-A, TYPE TEST FOR 2500 KVA, 11kV 0.433kV Transformers Details as per Annexure-I PART-A S. No. 3 1 Lot 340
7 PART-A, EXTRA OIL 5 PERCENT FOR 630 KVA TRANSFORMERS PART-A, EXTRA OIL (5 PERCENT) FOR 630 KVA TRANSFORMERS 1 Lot 340
8 PART-A, EXTRA OIL 5 PERCENT FOR 2000 KVA TRANSFORMERS PART-A, EXTRA OIL (5 PERCENT) FOR 2000 KVA TRANSFORMERS 1 Lot 340
9 PART-A, EXTRA OIL 5 PERCENT FOR 2500 KVA TRANSFORMERS PART-A, EXTRA OIL (5 PERCENT) FOR 2500 KVA TRANSFORMERS 1 Lot 340
10 PART-A, Mandatory Spares for 630 KVA Transformers, refer BOQ Annexure-II for details, attached with specification PART-A, Mandatory Spares for 630 KVA Transformers, refer BOQ Annexure-II for details, attached with specification 1 Set 730
11 PART-A, Mandatory Spares for 2000 KVA Transformers, refer BOQ Annexure-II for details, attached with specification PART-A, Mandatory Spares for 2000 KVA Transformers, refer BOQ Annexure-II for details, attached with specification 1 Set 730
12 PART-A, Mandatory Spares for 2500 KVA Transformers, refer BOQ Annexure-II for details, attached with specification PART-A, Mandatory Spares for 2500 KVA Transformers, refer BOQ Annexure-II for details, attached with specification 1 Set 730
13 PART-B, 16 MVA, 11kV 3.45kV, 3 phase, 2 winding, outdoor, ONAN, please refer BOQ and technical specification uplodaed for details PART-B, 16 MVA, 11kV 3.45kV, 3 phase, 2 winding, outdoor, ONAN, please refer BOQ and technical specification uplodaed for details 2 Nos 325
14 PART-B, TYPE TEST FOR 16 MVA, 11kV 3.45kV Transformers, Details as per Annexure-I PART-B S. No. 1 PART-B, TYPE TEST FOR 16 MVA, 11kV 3.45kV Transformers, Details as per Annexure-I PART-B S. No. 1 1 Lot 325
15 PART-B, EXTRA OIL 5 PERCENT FOR 16 MVA TRANSFORMERS PART-B, EXTRA OIL (5 PERCENT) FOR 16 MVA TRANSFORMERS 1 Lot 325
16 PART-B, Mandatory Spares for 16 MVA Transformers, refer BOQ Annexure-II for details, attached with specification PART-B, Mandatory Spares for 16 MVA Transformers, refer BOQ Annexure-II for details, attached with specification 1 Set 730

Corresponding Contract Award Notice

No Contract Award Notice found for this tender. Please try using the Contract Award Search Page.


Request Demo
GiZ Tenders India