1 |
PART-A, 630 KVA, 11kV 0.433kV, 3 phase, 2 winding, outdoor, ONAN, please refer BOQ and technical specification uplodaed for details |
PART-A, 630 KVA, 11kV 0.433kV, 3 phase, 2 winding, outdoor, ONAN, please refer BOQ and technical specification uplodaed for details |
2 |
Nos |
340 |
|
2 |
PART-A, 2000kVA, 11kV 0.433kV, 3 phase, 2 winding, outdoor, ONAN, please refer BOQ and technical specification uplodaed for details |
PART-A, 2000kVA, 11kV 0.433kV, 3 phase, 2 winding, outdoor, ONAN, please refer BOQ and technical specification uplodaed for details |
6 |
Nos |
340 |
|
3 |
PART-A, 2500kVA, 11kV 0.433kV, 3 phase, 2 winding, outdoor, ONAN, please refer BOQ and technical specification uplodaed for details |
PART-A, 2500kVA, 11kV 0.433kV, 3 phase, 2 winding, outdoor, ONAN, please refer BOQ and technical specification uplodaed for details |
2 |
Nos |
340 |
|
4 |
PART-A, TYPE TEST FOR 630 KVA, 11kV 0.433kV Transformers Details as per Annexure-I PART-A S. No. 1 |
PART-A, TYPE TEST FOR 630 KVA, 11kV 0.433kV Transformers Details as per Annexure-I PART-A S. No. 1 |
1 |
Lot |
340 |
|
5 |
PART-A, TYPE TEST FOR 2000 KVA, 11kV 0.433kV Transformers Details as per Annexure-I PART-A S. No. 2 |
PART-A, TYPE TEST FOR 2000 KVA, 11kV 0.433kV Transformers Details as per Annexure-I PART-A S. No. 2 |
1 |
Lot |
340 |
|
6 |
PART-A, TYPE TEST FOR 2500 KVA, 11kV 0.433kV Transformers Details as per Annexure-I PART-A S. No. 3 |
PART-A, TYPE TEST FOR 2500 KVA, 11kV 0.433kV Transformers Details as per Annexure-I PART-A S. No. 3 |
1 |
Lot |
340 |
|
7 |
PART-A, EXTRA OIL 5 PERCENT FOR 630 KVA TRANSFORMERS |
PART-A, EXTRA OIL (5 PERCENT) FOR 630 KVA TRANSFORMERS |
1 |
Lot |
340 |
|
8 |
PART-A, EXTRA OIL 5 PERCENT FOR 2000 KVA TRANSFORMERS |
PART-A, EXTRA OIL (5 PERCENT) FOR 2000 KVA TRANSFORMERS |
1 |
Lot |
340 |
|
9 |
PART-A, EXTRA OIL 5 PERCENT FOR 2500 KVA TRANSFORMERS |
PART-A, EXTRA OIL (5 PERCENT) FOR 2500 KVA TRANSFORMERS |
1 |
Lot |
340 |
|
10 |
PART-A, Mandatory Spares for 630 KVA Transformers, refer BOQ Annexure-II for details, attached with specification |
PART-A, Mandatory Spares for 630 KVA Transformers, refer BOQ Annexure-II for details, attached with specification |
1 |
Set |
730 |
|
11 |
PART-A, Mandatory Spares for 2000 KVA Transformers, refer BOQ Annexure-II for details, attached with specification |
PART-A, Mandatory Spares for 2000 KVA Transformers, refer BOQ Annexure-II for details, attached with specification |
1 |
Set |
730 |
|
12 |
PART-A, Mandatory Spares for 2500 KVA Transformers, refer BOQ Annexure-II for details, attached with specification |
PART-A, Mandatory Spares for 2500 KVA Transformers, refer BOQ Annexure-II for details, attached with specification |
1 |
Set |
730 |
|
13 |
PART-B, 16 MVA, 11kV 3.45kV, 3 phase, 2 winding, outdoor, ONAN, please refer BOQ and technical specification uplodaed for details |
PART-B, 16 MVA, 11kV 3.45kV, 3 phase, 2 winding, outdoor, ONAN, please refer BOQ and technical specification uplodaed for details |
2 |
Nos |
325 |
|
14 |
PART-B, TYPE TEST FOR 16 MVA, 11kV 3.45kV Transformers, Details as per Annexure-I PART-B S. No. 1 |
PART-B, TYPE TEST FOR 16 MVA, 11kV 3.45kV Transformers, Details as per Annexure-I PART-B S. No. 1 |
1 |
Lot |
325 |
|
15 |
PART-B, EXTRA OIL 5 PERCENT FOR 16 MVA TRANSFORMERS |
PART-B, EXTRA OIL (5 PERCENT) FOR 16 MVA TRANSFORMERS |
1 |
Lot |
325 |
|
16 |
PART-B, Mandatory Spares for 16 MVA Transformers, refer BOQ Annexure-II for details, attached with specification |
PART-B, Mandatory Spares for 16 MVA Transformers, refer BOQ Annexure-II for details, attached with specification |
1 |
Set |
730 |