INDIAN ARMY has floated a tender for Corrigendum: Excavation Soft and Loose Soil not Exceeding 1 Point 5 Metre Deep and Wide, Returning Filling in Soi, Qty: 3438. The project location is Panchkula, Haryana, India. The reference number is - and it is closing on 14 Nov 2026. Suppliers can request Register free of cost to get the complete Tender details and download the document.
Procurement Summary
State: Haryana
Summary: Corrigendum: Excavation Soft and Loose Soil not Exceeding 1 Point 5 Metre Deep and Wide, Returning Filling in Soi, Qty: 3438
Deadline: 14 Nov 2026
Posting Date: 08 Nov 2026
Other Information
Notice Type: Tender
TOT Ref.No.: 152201192
Document Ref. No.: Login to see detail
Financier: Self Financed
Purchaser Ownership: Public
Document Fees: Refer Document
Tender Value: Refer Document
EMD: ₹ 438000
Purchaser's Detail
Name: Login to see details
Address: Login to see details
Email: Login to see details
Login to see detailsTender Details
Descrption: Login to see details
IMP: Login to see details
Contact Details: Login to see details
Documents
| # | Title | Description | Qty | Unit | Delivery (Days) |
|---|---|---|---|---|---|
| 1 | Excavation soft and loose soil not exceeding 1 point 5 metre deep and wide | Excavation in trenches in soft & loose soil not exceeding 1 point 5 metre deep and not exceeding 1 point 5 mtr wide | 175 | Cum | 180 |
| 2 | Returning filling in soilsspreading leveling watering and well ramming | Returning, filling in soils including spreading leveling watering and well ramming | 127 | Cum | 180 |
| 3 | Removal of surplus Soils not exceeding 50 Mtr distance | Removal of surplus excavated Soils not exceeding 50 Mtr distance and depositing | 48 | Cum | 180 |
| 4 | M and L for sand filling with clean dry find sand unwashed | Material & labour for sand filling with clean dry find sand unwashed | 44 | Cum | 180 |
| 5 | S and L un reinforced pre cast flat concrete cable protection cover | Supplying and Laying un reinforced pre cast flat concrete cable protection cover of class HV type I size 300mm x 180mm x 40mm | 2500 | Each | 180 |
| 6 | S and fixing on HT pole danger notice plate for HT 11KV | Supply and fixing on HT pole danger notice plate for HT 11KV of size 25 cm x 20 cm | 13 | Each | 180 |
| 7 | Tubes light grade galvanised of size 80 mm | Tubes light grade galvanised with all fitting and fixed complete to walls and ceilings or laid in floors of size 80 mm | 5 | RM | 180 |
| 8 | M and L for earthing complete with GI steel earth plate 600mm x 600mm x 6mm | M and L for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth | 16 | Each Job | 180 |
| 9 | M and L earthing complete with copper earth plate of size 600x600x3point 5 mm | All as per item ser No 13 here-in-before but copper earth plate of size 600mmx600mmx 3 point 5 mm and connected with copper strip of size 20 x 3 mm complete all | 8 | Each Job | 180 |
| 10 | Supply and fixing in repair Lightning arrester single pole 11 KV 65 Kilo Amp | Supply and fixing in repair Lightning arrester single pole 11 KV 65 Kilo Amp | 1 | Each set of three | 180 |
| 11 | SITC of 11KV SF6 gas 4way RMU 630 Amps | SITC of 11KV Extensible Outdoor duty IP 55 enclosure SF6 gas insulated 4way motor operated RMU of 01 nos 630 Amps Load Break Switch as incomer and 03 nos 630 AmpsVacuum Circuit Breaker as outgoing | 1 | Each | 180 |
| 12 | SITC of 11KV 630A switch SF6 disconnector outdoor panel | SITC of 11KV 630A switch SF6 disconnector outdoor panel for protection of various transformers | 5 | Each | 180 |
| 13 | Supply and installation and testing 11 KV outdoor type GOD | Supply and installation and testing 11 KV outdoor type , gang operated Air break switch triple pole mechanically operated | 1 | Each | 180 |
| 14 | SITC of 100 KVA Level 03 transformer 11KV on HT and 433 volts on LT side | SITC of capacity 200 KVA, Level 03 outdoor transformer floor mounted 11KV on HT side and 433 volts on LT side | 2 | Each | 180 |
| 15 | SITC of 125 KVA Level 03 transformer 11KV on HT and 433 volts on LT side | SITC of capacity 160 KVA, Level 03 outdoor transformer floor mounted 11KV on HT side and 433 volts on LT side | 2 | Each | 180 |
| 16 | SITC of 160 KVA Level 03 transformer 11KV on HT and 433 volts on LT side | SITC of capacity 100 KVA, Level 03 outdoor transformer floor mounted 11KV on HT side and 433 volts on LT side | 1 | Each | 180 |
| 17 | Taking out of transformers 100 KVA to 500 KVA depositin in MES yeard | Taking out of transformers of capacity 100 KVA to 500 KVA carefully from two pole or four struction and depositin in MES store yeard | 5 | Each | 180 |
| 18 | Taking out old unsv HT UG cable of any size | Taking out old unsv HT UG cable of any size | 25 | RM | 180 |
| 19 | Dismantling air break gang operated switches | Dismantling air break gang operated switches vertical/horizontal mounted including insulators and operating mechanism | 1 | Each | 180 |
| 20 | SITC 11 KV cables conforming to IS 7098 Part-II 95 Sqmm 3 core | SITC 11 KV Earthed aluminium conductor screened XLPE insulated armoured shielded and PVC sheathed cables conforming to IS 7098 Part-II 95 Sqmm 3 core | 450 | RM | 180 |