Expired Tender Germany ICB TOT Ref. 7825778

Darkfield and scanning probe microscopes Tender in Germany - 7825778

Tender notice from Germany, published on 19 Aug 2016.

Executive Summary

The Deutsche Forschungsgemeinschaft e. V., Zentrale Beschaffungsstelle has issued a Tender notice for the procurement of a Darkfield and scanning probe microscopes in the Germany. This Tender notice was published on 19 Aug 2016 and is scheduled to close on 14 Sep 2016, with an estimated Tender value of Refer Document. Interested bidders can access detailed Tender information, eligibility criteria, and complete bidding documents by referencing TOT Ref No. 7825778, while the tender notice number is 286493-2016 and Register on the platform.

Key facts

Summary
Darkfield and scanning probe microscopes
TOT Ref. No.
7825778
Document Ref. No.
286493-2016
Country
Germany
Notice type
Tender
Competition
ICB
Publication date
19 Aug 2016
Bid deadline
14 Sep 2016
EMD
Refer Document
Tender value
Refer Document
Purchaser ownership
-
Financier
Self Financed

CPV classification

Purchaser details

Purchaser contact is for registered users

Login to see details

Tender details

Object of the contract

Specifications "cryogenic scanning probe microscope" .Ausgeschrieben is the manufacture, delivery and installation on site of a low-temperature scanning probe microscope for simultaneous measurement of tunneling current and frequency shift on surfaces of metallic, semiconducting and non-conductive materials by means of combined scanning tunneling and dynamicAtomic force microscopy for operation under ultra-high vacuum conditions and at temperatures of 300K to less than 6K. The microscope will be delivered with the needed to operate the vacuum chamber. Another, associated with this chamber but severable per valve recipient to Probenpraeparation by ion bombardment and heating as well as the Deposition of molecules, metals and inorganic compounds of up to at least 150K-cooled and up to at least 1070K heated samples unterstuetzen.Im specifically intended to include the delivery, the following components, which are specified in detail in the next sections: (1) An ultra-high vacuum system consisting of two recipients and a lock, including methodology for generating a vacuum, vacuum control and residual gas analysis; (2) a low-temperature scanning probe microscope for the low-noise simultaneous measurement of tunneling current and frequency shift for atomic imaging of surfaces of metallic, semiconducting, and especially non-conductive materials; (3) electronics and software for driving the scanning probenmikroskops and (4) methodology for the preparation of Probenoberflaechen and the deposition of molecules, metals and inorganic compounds, including a coating thickness measurement. Further instructions concerning commissioning, briefing and documentation are (5) gelistet.Das system to be supplied as operational system and apart from usual Verbrauchsmaterialien and require no on-sample components for the specified power (1) ultra-high vacuum system. The ultra-high vacuum system is isolated from 2 pumped recipients exist. This recipient is A for the installation of a low-temperature scanning probe microscope and recipient B for the Propenpraeparation and possibly Vorcharakterisierung (apart from scanning probe microscopy experiments) designed. The recipients should be separated from each other by a valve and a device for the transfer of samples under vacuum between the recipient has given sein.Rezipient A must fulfill the conditions for the operation of the scanning probe microscope described in (2). Recipient B is soi?1/2be designed so that in addition to installation of the methodology described in (4) an extension to more typical analysis of Oberflaechenphysik: such as photoelectron spectroscopy: at a later date possible ist.Jeder recipient should be pumped separately with ion getter and titanium sublimation, as well as separately or in combinationi?1/2fitted a turbo molecular pump and backing pump sein.Die pump power is to be interpreted as a print specification of at least 3x10-10 mbar or better for separated each chamber can be achieved. Both recipients are each fitted with suitable measuring sensors and display devices for pressure measurement. The ultrahigh vacuum chamber is made of staitmagnetischem stainless steel sein.Zusaetzlich to these two recipients to the system with a sluice for introducing samples and measuring probes (for the scanning probe microscope) be provided which allows a separate pumping and baking in a third receptacle and thereby specifically avoids venting of the entire system, A Transfermoeglichkeit from the lock in one of the recipient A or B is given sein.Alle recipients should allow with appropriate windows, the simple optical access for all steps to be equipped. Furthermore, at both recipients flanges in accordance with the requirements of the methodology listed here and in (4), as well as for typical Advanced modelsments provide. The exact number and position of the flanges are in procurement in consultation and taking into account the technical possibilities spezifiziert.Das vacuum system to be mounted on luftgedaempften, antivibration feet which the stoerungsfreien operation of the scanning probe microscope in all modes of operation by filtering von disturbances around erlaubt.Das system is intended to provide tidying comfortable carrying out the heating process, and ideally the heating elements have permanently installed. Furthermore, to provide the system a Ausheizzelt, Ausheizpaneele or similar thermal insulation for comfortable attachment to the vacuum system. Additionally to das system, a control system for controlling the Ausheizvorgangs include that enables specifically a digital time and temperature control. This control system will be continued during the Ausheizvorgangs equipped with safety locks to control switching of pumps and valves as well as during normal operation. The combined control system soll external access the system parameters via software ermoeglichen.Das vacuum system and under points (1), (2) and (4) listed vacuum components should be baked sein.Mit the system continues to be a tool for residual gas analysis of recipient B to be delivered. This instrument is a mass range of mindestens1: cover 200 amu. The instrument isi?1/2ready, d. h. including possibly required electronic unit and software to deliver. As flange DN40CF should be provided (2) low temperature scanning probe microscope. The scanning probe microscope has the separate or simultaneous operation as scanning tunneling and atomic force microscope frequency modulated by separate or simultaneous measurement of Tunnelstroms and the frequency shift of a vibration sensor ermoeglichen.Das scanning probe microscope has to be designed for the time, reliable atomic imaging of various surfaces. Especially to the scanning probe microscope imaging following samples allow atomic dissolution: (1) surfaces of metallic materials (such as Cu (111) ori?1/2Au (111)); (2) surfaces of semiconducting materials (such as Si (111) or Si (001)); . (3) surfaces of non-conductive materials (such as NaCl (001), KBr (001), CaF2 (111) or CaCO3 (104)) In order to demonstrate this Capability is to show especially when the device is delivered as an acceptance criterion on the spot: ( 1) obtaining atomic Contrast on metallic or semiconducting sample at room temperature in scanning tunneling mode; (2) obtaining atomic contrast to metallic or semiconducting sample at T as a sensor support for simultaneous measurement of tunneling current and frequency shift is to be provided from the following 2 options A or B: (A) In Option A is the direct supporti?1/2of qPlus (r) sensors or similar, mechanically excited tuning fork or piezoelectric vibration sensors having usually metallic, wet chemical etched tip and with frequencies in the range 20-100kHz (hereinafter referred to as sensor Type 1 refers) given. Additionally to the microscope in this option for use with Hummingbird (R) Sensors or comparable electrically excited, laengsschwingenden electrically encapsulated piezoelectric vibration sensors with vibration frequencies to 1MHz and angefuegter peak (hereinafter referred to as sensor type 2 hereinafter) to be designed. In preparation for the support of this sensor type add one single electrical cable is particularly provide, which allows the transmission of signals to 1MHz from the sensor receptacle of the vacuum system. (B) can alternatively be configured in Option B directly for use with sensor Type 2, the Geraet, in this case, the support of sensor type 1 does not necessarily notwendig.Die top said acceptance criteria are two options with only one type of sensor toi?1/2fulfill. The directly supported sensors to be changeable in situ, ie the sensor replacement no aerating the Geraets erfordern.Als sensors for the measurement of tunneling current signals, ie in operation as a pure scanning tunneling microscope, are etched by wet chemical, sharp metallic tips are used ki?1/2nnen.Die electrical compensation of Sr.ingungssignals is so little noise as possible to be executed when the for atomic force microscopy typically required bandwidth. In the case of Option A the Signalverstaerkung is either implemented completely outside the vacuum system or technically designed so that signals you will pay to 1MHz without strong Damping can. Ideally ermoeglicht this concept continues to field emission from the probe tip within the Messkopfes.Das noise of the current detection (measured at for scanning tunneling microscopy usual bandwidth) should be as small as possible. Currents of 2PA and less should be measured, and should (if necessary at reduced Verstaerkung) a bandwidth of mind. 10kHz se feasiblein. The current detection to both peak and to sample side possible sein.Die mechanical stability of the measuring head must be protected by appropriate Daempfungssysteme within the measuring head and a noise or disturbances along the Z axis (in the scanning tunneling microscopy tunnel junction) of ideally 2 pm and less erlauben.Das Geraet is witha number of ready to use vibration sensors of the direct support type are supplied with high vibrational qualities Q, as well as with Sensortraegern for mounting individual vibration sensors. Furthermore Sensortraeger for pure tunnel sensors should be supplied (with no top wire), and accompanied by complete usable tunnel sensors. Additionally are genuegend transfer facilities for the storage of the sensors within the vacuum system and / or possibly required equipment or tools for the transfer to liefern.Das microscope to allow operation in the temperature range of 300K to less than 6K, where both the sample and the peak temperatures of less to achieve than 6K. The Kuehlung to dhrough be realized a bath cryostat, which a possible long life in both T The sample receiving the measuring head to be compatible with Specs (r) / Omicron (r) sample holders (or Comparable). The sample is to be changeable in-situ and in cold probe, a transfer between specified under (4) manipulator and to the hereafter spezifizierten stock possibility must possible sein.Die probe must be positioned relative to the sample by appropriate interlocking systems. Here, a possible large area along the X, Y and Z is to enable axes. Especially should can be used samples with a height of 5 mm and more, and a possible large area se laterally approached on the samplein. The scan area of the microscope to be as large as possible along the X, Y and Z axes as well. Specifically, it should be possible to examine flat samples for possible large scale to koennen.In the sample collection within the measuring head are at least two additional electrical contacts to provide sample holder. These contacts should additionallyi?1/2be the scanning tunneling signal executed. These contacts should be designed so that they are during scanning probe microscopy measurements usable. The delivery of Geraets should include appropriate sample holder with access to create the additional electrical contacts, provided that the contacts sind.Weiterhin not basically executed in the sample holders soll of the supplied additional sample holder (ideally of molybdenum) for the recording and preparation of semi-conductive samples such as Si (111) or Si (001), and other sample holder (ideally from molybdenum or tantalum) for the inclusion of metallic samples such. B . Cu (111) and Au (111) and another blank sample plates (ideally from molybdenum ori?1/2Tantalum) for individual assemblies include. The sample holder must rehearsing specific in-situ preparation of the respective types of samples in the supplied Geraet ermoeglichen.In close to the measuring head to warehouse platforms for samples and measuring sensors can be provided. A cooled transfer of samples and probes between bin and probe must in-situ and inbe em probe possible. Furthermore, a transfer from the specified under (4) manipulator arm into the measuring head should be possible without the sample warms up strongly. Ideally, at least one of the samples bearing is designed so that the sample can be stored refrigerated kann.Der probe should be at least two optical window for optical control of SpItze and sample hold, and provide at least one access, which allows depositing of metals, molecules or inorganic compounds with the deposition apparatus described in (4) directly to the test in the measuring head (3) control electronics for scanning probe microscope. A control electronics for the combined scanning tunneling - and Rasterkraftmikroskop in frequency modulated mode to produce all low and high voltage signals and for processing, analysis and storage of all input signals shall be supplied to the vacuum chamber and the scanning probe microscope. The electronics should continue driving the coarse positioning of the probe relative to the sample realisieren.Die electronics to d(Especially the analog to digital, digital to analog conversion and signal processing power) and the software (specifically described below, the provision of individual script opportunity and a programming interface) satisfy s current standard concerning the hardware used. In addition to the 8 measuring channels typical topography, Tunnelstrom, frequency offset, phase, amplitude, excitation amplitude, Kelvin probe signal and Kelvin probe error signal to a minimum. 5 additional analog Eingangskanaele at leisure be present. Furthermore, the connection of an external phase-locked loop including access to the input signal of the control circuit topography is possible sein.Die electronics to allusual modes of scanning probe microscopy support. For this count in particular :: imaging mode in current and frequency shift control ;: "multipass" or "lift-off" mode ;: Kelvin probe microscopy ;: Spektroskopiemodi for scanning tunneling microscopy (z. B. STS, IETS) ;: Spektroskopiemodi for atomic force microscopy (z. B. DF (V), df (z)) ;: "Grid spectroscopy"This data is systematically recorded along all three spatial directions and stored as volume data set ;: AFM mode constant amplitude ;: manipulation experiments, especially the definition of and movement along individual paths in the Probenoberflaeche.Fuer the Kelvin probe microscopy and atomic force microscopy modeconstant amplitude are to provide each additional required controller in electronics. These are interpreted as at least proportional-integral controller (or equivalent). The topography loop should continue to have devices to protect the measuring tip ( "tip guard") in critical condition, the sensor vibration or the measuring electronics. Idealerweise is also a limitation of the maximum frequency shift range of the frequency detection moeglich.Zur detection of frequency shift to a dedicated phase-locked loop in here especially for suitable hardware or software used and supplied. The detection is intended to support both types of sensors, ie a detection range of the sensor vibrationpermit of mind. 10kHz to 1.5MHz and to allow for a possible large bandwidth range of the frequency demodulation, but at least 1 kHz. The parameters for operation of the frequency shift detection should be accessible by software. The input noise of the oscillation signal channel is as low as possible sein.Die Ausgangskanaele for the piezo signalsto both high dissolution to fine addressable positioning of the probe relative to the sample permit as also a possible low self noise. Furthermore, should a mechanical excitation of piezoelectric sensors suppressed by output noise on the piezo signals werden.Die electronics with the required for operation Software geliefert. Any necessary program updates for the measuring software are provided by possibility with no time limit for disposal. The software is currently the usual standard as regards the flexibility of the experiments meet and support the above listed modes. Here, the software is specially possibilities for automated Ansteuerung permit (eg., by a scripting language), and allow external access (eg., by a put to disposal API). Both access facilities should ideally cover the entire operating range of electronics, d. H. Access to both make the rough positioning, scanning motion and the recorded signals at your disposal. Furthermore, sadit in the software possibilities exist to represent the signals not only as a function of tip position, but also as a time series. The system also is a possibility to access and display of measurement data werden.Ein delivered according to the current standard leistungsfaehiger computer workstation including display for use dhe measurement software is included with the device (4) methodology for Probenpraeparation:. The system should include a sample receiving in recipient B, which in the time specified in (2) sample holders to the built-up the positioning of different samples to recipient B, allowing 'the listed methodology, This manipulator is a movement along alli?1/2three spatial directions X, Y and Z allow, and a rotation of the sample to 360 erlauben.Die sample receiving to allow through a built-in heater, a sample temperature of at least 1 070K and the system with the here for necessary connection cables and the required power supply are supplied. is a measurement of the temperature of the manipulatorbe possible by the incorporation of a suitable sensor. Ideally, the power supply is possible to ansteuern.Weiterhin by a programming this or another sample receiving his cooled, here is a sample temperature of 150K and achieve less. The system should mitliefern the Kuehlen the perfect accessories (exclusive cryogenic media), soas also allow temperature measurement by incorporation of a suitable sensor. A transfer of the cooled sample of these samples included in the scanning probe microscope is possible sein.Diese or another sample receiving should be designed for the recording of measuring probes and to specifically allow ion bombardment on the probes. This soll geometry ideally a bombardment from the front, that is directed to the ion beam is perpendicular to the top, vorsehen.Mindestens a sample shots is at least one electrical contact (in addition to ground) connect to the sample holders, which the preparation of surfaces of semiconducting materials such ., Si (111) or Si (001), byi?1/2Direct current heating possible. The electrical contact as well as the supply lines are for a current of at least 8 A designed sein.Das system should include a device for the deposition of different molecules, metals, and inorganic compounds. This device is the simultaneous or sequential deposition of at least two Materialien enable the sequential deposition time must not be delayed significantly. A temperature of approximately 2 270K or more for deposition of metals with high melting point is can be achieved. Furthermore, a device has to be created for possible ions that may arise when heated the materials to filter out. The Instinstrument panel is fully operational (d. h., including connecting cables, control unit and, if required software) to deliver and must be designed for the ultra-high vacuum operation. The device should be mounted on a flange DN40CF and be positioned relative to the sample in accordance with the recipient B needed focal point. Furthermore, it is possible sa, the deposition source for the direct deposition of materials on which the scanning head located at the sample recipient A anzubauen.Zur control the deposition should be designed with a Duennschichtmonitor in recipient B the system. This should be positioned under ultrahigh vacuum conditions at the site of the sample and an accuracy of Schichtdickenaufloesung of at least 1 A permit. The Duennschichtmonitor is fully operational, d. H. Including possibly required vacuum components, connection cables, control unit and, if required software to liefern.Zur preparation of probes and finishes to be delivered an ion source for bombardment with ionized noble gases. To a high purityshould contain a filament ensure the ion beam, the ion source, which ideally additionally not line-in-sight is to sample. Adjustable beam energies should cover at least the energy range from 0.5 to 2keV and the beam diameter should correspond to the Probengroesse. The instrument is intended for the operation other than the ultra-high vacuumare ready to use. if necessary software will be elegt and including control unit, electrical connection cables and including delivered (5) other requirements. The system is: apart from usual consumables and resources such as cryogenic media, compressed air or electricity.. The system is constructed by qualified personnel on site and in Beoperation are taken, this above-specified acceptance criteria are more particularly with regard to fulfilling angular resolution. The shipment of the system is to take over from the manufacturer. With or additionally to the decrease in Geraets a briefing of the academic staff on site is durchzufuehren.Dem delivery includes documentation and / or Bedienungsanleitungen all components add. The documentation should be as comprehensive as possible sein.Der provider of the device to provide services even after delivery. This should be verfuegbar to requesting technical trained personnel, as well as its procurement of possibly needed spare parts and commissioning in case of repairs possible. furthermoreshould be long verfuegbar by the manufacturer of the sensor type used as main sensor with high quality.
Description: Darkfield and scanning probe microscopes
Authority Type: Other

Contact Nature: Supplies

Procedure: Negotiated procedure

Document: Contract notice

Regulation: European Union

Award criteria: The most economic tender

CPV code: 38514000

CPV Description: Darkfield and scanning probe microscopes.  
Internet address (URL): www.dfg.de

Directive: Classical Directive (2004/18/EC)

Documents

Tender Notice
Login to view

Similar tenders

Tender Country TOT Ref. No. Bid deadline
L3236, Od Lohfelden (l 3203 - As Ks Industrial Park) Germany 152970378 03 Dec 2026
Supply of an Inertial Measurement Unit System ** Germany 152968320 15 Dec 2026
Re­Frac­Ti­Ve In­Dex Pro­Fi­Ler Germany 152966505 21 Dec 2026
Procurement of Cold Water Meters for Drinking Water Germany 152965537 14 Dec 2026
Purchase, Delivery and Installation of a System Wvtr Permeation Meter Germany 152965480 16 Dec 2026

Germany Public Procurement Intelligence

Frequently asked questions

The bid deadline for Darkfield and scanning probe microscopes was 14 Sep 2016. Bidding is closed.

This tender has been issued by Deutsche Forschungsgemeinschaft e. V., Zentrale Beschaffungsstelle in Germany.

The tender value is not disclosed; please refer to the tender document. EMD / bid security details are provided in the tender document.

This tender is Self Financed

The tender is classified under the following CPV code(s): 38514000 - Darkfield and scanning probe microscopes.

The tender notice and related documents are listed in the Documents section above. Select a document to view or download it. Please log in or register to access the documents. If you cannot find additional documents in the Documents section, please log in to your account and Send Document Request from your account section.

The TendersOnTime reference is 7825778. The purchaser document reference is 286493-2016.

See the Similar Tenders section on this page or browse other tenders from Germany.

This tender falls under Technology and Equipment in Germany. Suppliers in these sectors can track similar Germany tenders using CPV-based alerts.