Procurement Summary
Country: Germany
Summary: Contract notice: Industrial robots
Deadline: 09 Aug 2019
Posting Date: 11 Jul 2019
Other Information
Notice Type: Tender
TOT Ref.No.: 34586261
Document Ref. No.: 323495-2019
Competition: ICB
Financier: Self Financed
Purchaser Ownership: -
Tender Value: Refer Document
CPV Classification
42997300 - Industrial robots
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_details
Login to see detailsTender Details
Object of the contract
Industrial robots
Description: Contract notice: Industrial robots
Authority Type: Body governed by public law
Contact Nature: Supplies
Procedure: Open procedure
Document: Contract notice
Regulation: European Union, with participation by GPA countries
Award criteria: Lowest price
CPV code: 42997300, 42997300
CPV Description: Industrial robots.
Biocatalyst optimization workstation
A workstation is needed to optimize biocatalysts. Both strains should be tested for specific enzyme activities and enzymes optimized for their activity, substrate spectrum and stability by mutations. The process should be fully automatedThis includes growing / biocatalyst production, cell separation by centrifugation, addition of reagents, buffers and substrates, and analysis by absorbance, fluorescence, or luminescence. Furthermore, the separation of the substrates and products by SPE method should be carried out for a weiterfuehrende analysis by means of z. B. mass spectrometry.
Mayn Site: Technische Universitaet Muenchen
Liquid Dealer:
- active avoidance of contamination (eg HepaFilter, lid),
automat. Pausing of the process by manual intervention,
- integrated cameras:
check deck loading before process start,
automat. Recording and saving of malfunctions,
Control via remote desktop.
- Min. 25x free usable passive positions storageMicrotiter (MTP) & Deepwell Plates (DWP), Reserviors & Tip Boxes on the Platform,
- Min. 8 Additional Temperature Controlled Positions:
4C 50C for MTP, DWP, Reservior, if necessary min. 4 adapters each (Σ 12).
- further supply of materials (not on the platform):
min. 120 MTP with lid; 30 top boxes or 30 DWP,
automat. usable.
- 1x automat. refillable Reservior,
- Mofor tempering & shaking MTPs and DWP:
min. Temperature range of 4C 60C,
Schuettel frequency of 100 1500 rpm.
- 8-fold pipetting head:
fixed needles min. for 0.5 100 μl, max. Error / - 5% (5μl),
disposable tips min. for 10 1000 μl, max. Error / - 5% (10 μl),
each channel independently controlled & filled,
needle spacing variable for 6, 24, 96 & 384 pla
Calibration by user.
- 96 pipetting head:
disposable tips min. for 5 1 200 μl, max. Error / - 5% (5μl),
wash station,
selective pickup,
tip assignment with repetitive pipetting.
- Capacitive level measurement in the tips,
- min. 2 individually controllable gripping arms: rotation around 360; MTP & DWP transport & stacking with lid,
- activetiltable position decrease of overhangs
centrifuge:
- min. 2x MTP or 2x DWP,
temperature 4 30C,
centrifugation to 5 800 g.
MTP reader:
absorption (230 900 nm), fluorescence top & bottom (Ex: 250-830 nm), Em 270- 850 nm), luminescence (300-850 nm),
modes: end point, kinetics, emission and excitation scans,
shaking function,
temperature control 4C to 45C,
plate formats 6, 384 well.
Incubator for Bacteria & Yeasts:
- Tempering 4C-45C,
- Capacity 40 DWP or 80 MTP,
- Regulation Humidity min. zws. 20 70% RH,
orbital shaking.
Overpressure based SPE filtration unit:
- Filter plates 6-384 well & single columns,
- Software controlled pressure control,
- Stack height min. 20 cm,
height self-adjusting.
Calculator: Windows 10; large storage capacity &Memory
Software:
- secure system operation,
- Graphical interface for method generation,
- Drag & Drop functionality,
- copy & paste method elements, sections & transfer steps,
- method validation during creation Check for logical errors, support for troubleshooting & Specification of method duration,
- automatic nesting of processExpiration,
- scheduling, non-dynamic scheduling software,
- SQL database to automat. Save saemtl. Data with file-based data import / export.
Base / tables for all components of the workstation
Maximum space requirements: 3.6 mx 1.2 m or 2.4 mx 2.4 m (center 30 cm max height 1.83 m )
Installation, device acceptance and full user training on site and / or in the form of a Semfor the handling of the system and the software.
Provision of suitable sources (instructions, tutorials) for independent operation and cleaning.
Customer service and technical support must be available in Germany and be reachable by telephone during normal business hours in Germany. Service technicians within 50 km available.
All required specificationsmust be clearly visible in the offer documents. A layout and a concept suggestion must be submitted. To set up and implement a customized enzyme assay method on site, must be done within 3 months of acceptance. Required material at tips and plates for it as well as for a run under full utilization of the system capacity must be provided
Delivery until week 48, free place of use
The legal warranty starts after installation with the technical inspection.
See tender documents Document:
- 04 EU_Eigenerklaerung Suitability VgV under URL: https://www.deutsche-evergabe.de/
See tender documents Document:
- 04 EU_Eigenerklaerung Suitability VgV under URL: https://www.deutsche-evergabe.de/
Die TechnischeUniversity Muenchen can only pay in advance against a corresponding banker for the total amount to be paid.
Internet address (URL): www.tum.de
Documents
Tender Notice