Tender notice from Germany, published on 13 Sep 2019.
Executive Summary
The UNIVERSITÄTSKLINIKUM AACHEN AÖR has issued a Tender notice for the procurement of a Contract notice: Cardio-angiography devices in the Germany. This Tender notice was published on 13 Sep 2019 and is scheduled to close on 15 Oct 2019, with an estimated Tender value of Refer Document.
Interested bidders can access detailed Tender information, eligibility criteria, and complete bidding documents by referencing TOT Ref No. 36294412, while the tender notice number is 427901-2019 and Register on the platform.
Object of the contract Cardio-angiography devices Description: Contract notice: Cardio-angiography devices Authority Type: Body governed by public law Contact Nature: Supplies Procedure: Open procedure Document: Contract notice Regulation: European Union, with participation by GPA countries Award criteria: Mixed CPV code: 33123220, 33123220, 33123220, 33123210 CPV Description: Cardio-angiography devices. Cardiac-monitoring devices. Two-level angiography system for interventional cardiology and hemodynamic registration and information system for the cardiac catheterization laboratory Reference Number: 2019-0370-AJ - A two-plane angiography system for Interventional Cardiology (Lot 1), Main Site: Aachen University Hospital AoeR Zwei-EbeNEN angiography system with dynamic flat-panel detectors and integrated digital image processing for diagnosis and intervention in vascular and in particular cardiovascular examinations. The design of the system should provide all necessary degrees of freedom during the examination, especially in all interventional procedures. Important here is unrestricted patient accessOver the entire examination area. The ground and ceiling-mounted 2-level C-arm angiography system is designed to provide high rotation and angulation speeds, which are monitored via active, electronic collision protection. The floor system should allow for rotations of at least 20 degrees / s in the routine and angulations of at least 18 degrees / s. In addition, wequasi three-dimensional Gefaessdarstellungen with high-speed rotations vonmind. 40 degrees / s. The system should guarantee a spherical object-centric adjustment technique with remote-controlled motor device movement for recording stands, including adjustment of the internal geometry and radiation diaphragms around the isocenter, with freely selectable projection direction. It is with allen projections to provide a vertical television picture. In the examination room, a display pen should inform about system status at all times. The system is mainly used in interventional cardiology and pediatric cardiology. For paediatrics, the system should allow recording at 60 B / s (monoplan and biplan). The display should be in a 1k2 matrix and theIn an emergency situation, the table must be freely accessible as soon as possible, the mounting stand and / or the table must allow manual rotation or displacement. An ACIST CVi injector should be included. The system should be assembled with a "haemodynamic recording and information system" from the company metek (see lot 2)system consisting of: - Multiaxial floor and ceiling-mounted imaging systems, - Patient positioning system, - High-resolution area detector systems, - Digital image processing and display system, - Roentgen generator systems with anode load calculator, automatic exposure measurement unit and surface dose product display, - High performance X-ray sources with automatic depth diaphragm and remoteeditable semitransparent filters as well as various spectral beam filters with Cu, interfaces for data communication and system control, - Multimodal postprocessing and findings workstation with application specific image postprocessing software, - Passive radiation protection, surgical light and other accessories. Documents to be submitted: - Occupational or commercial register extract (with doffer by means of a third-party declaration): Valid extract from the commercial register of the registered office or place of residence, insofar as the entry in the register is required under the statutory provisions of the Member State in which the candidate has his registered office, self-declaration suitability (124) (with the offer by means of self-declaration): Self-declaration to the suitability for not praequa♦ Documents to be submitted: - 521 EU - Self-explanations Exclusionary reasons (to be submitted with the offer by means of self-declaration): Declaration that no exclusion reasons acc. - 123 and 124 of the law against competition restrictions (GWB) are present, - liability insurance (with the offer by third clarification to submit): valid proof over die paid liability insurance. Age of the certificate 1 year max., - turnover and earnings performance of the last 3 business years in the area of the advertised services (to be submitted at the request of the contracting authority by means of self-declaration). The subject of the invitation to tender is within the framework of the DFG programs "Large-Scale Countries" or "Research Equipment" "funded and funded by the DFGd / or MIWF NRW pro rata funding. Accordingly, the decision of the MIWF NRW on "Grants for supplementation and renewal" of 27 January 2015 applies to this award procedure. As a result, the following points are to be considered in the further proceedings: The application for the granting of the grant is made by the AG on the basis of the award note after examinationof the offers received. The award in the award procedure may in principle be issued only after the validity of the grant decision or under the reservation of the allocation of the state funds. In the event of a negative decision by the grantor, the award procedure will be abolished, as the funds required for commissioning will then be unavailable. Accordingly, canConfidence in bidding on the bidder side can not be justified by the submission of the bid. An assertion of claims for damages in the case of a cancellation of the award procedure due to a non-grant of the required donation to the client is excluded to this extent. On the basis of o. G. Facts is the period of validity of the offers (binding period) grosszuegmeasured. The AG reserves the right to extend the binding period until the decision on the donation and will ask the participating bidders / bidders in good time. The information contained in these tender documents are protected as far as they are protected and unless they contain third party information Property of the awarding authority. Utilization, copy and distribution of the VeEntry documents are only permissible in the context of the preparation of an offer and only by the company requesting the tender documents. Any further disclosure and, in particular, the sale of tender documents to third parties for any purpose is not permitted. If you do not receive the tender documents directly from the awarding authority or from the awarding marketplace of the Lands through service providers or commissioned third parties will give you a registration on the publicity marketplace of the state of North Rhine-Westphalia and a participation over v. G. Procurement Marketplace recommended. Tender documents may be amended or supplemented, the bidder communication, the i. d. R. is the only means of communication that can be given explanatory hintsNormally, the latest and most up-to-date information on this procurement procedure can only be found on the award marketplace of the state of North Rhine-Westphalia. In the event that the contractor fails due to cancellation or insolvency before full performance of the contract, the client reserves the remaining work to the rest Tenderers in the order of the tender resultsto submit it (- 132 Abs. 2 Nr. 1 GWB) Any communication between bidder and AG should be made via the assignment.nrw message function Announcement ID: CXS0YYJYD6D Internet address (URL): https://www.ukaachen.de
The bid deadline for Contract notice: Cardio-angiography devices was 15 Oct 2019. Bidding is closed.
This tender has been issued by UNIVERSITÄTSKLINIKUM AACHEN AÖR in Germany.
The tender value is not disclosed; please refer to the tender document. EMD / bid security details are provided in the tender document.
This tender is Self Financed
The tender is classified under the following CPV code(s): 33123220 - Cardio-angiography devices, 33123210 - Cardiac-monitoring devices.
The tender notice and related documents are listed in the Documents section above. Select a document to view or download it. Please log in or register to access the documents. If you cannot find additional documents in the Documents section, please log in to your account and Send Document Request from your account section.
The TendersOnTime reference is 36294412. The purchaser document reference is 427901-2019.