Procurement Summary
Country: Brazil
Summary: AQ. OF ULTRASSOM APPLIANCE
Deadline: 01 Nov 2016
Posting Date: 13 Feb 2017
Other Information
Notice Type: Tender
TOT Ref.No.: 10943692
Document Ref. No.: SUSAM-CAE022/16
Competition: ICB
Financier: Self Financed
Purchaser Ownership: -
Tender Value: Refer Document
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_details
Login to see detailsTender Details
Description:- 1) (ID-115430) ULTRASOUND APPLIANCE, Application: adult, pediatric and neonatal; Three-dimensional, high resolution digital echocardiography system for general use in two-dimensional and three-dimensional cardiology, vascular, cerebrovascular, peripheral vascular, transcranial, transfontanelar and TEE. MoNitor min. 19 `` LCD, fully articulable; Touchscreen touchscreen attached to the panel; Modes B, BB, BM, M full screen; Tissue Doppler function (color and spectral, pulsed and continuous) in full screen; Colorization of images in B, M and Doppler modes; Min Rate Frame Of 500 squareS / second; Elastography based on highly sensitive strain that does not require external compression, benefiting from cardiac and respiratory movements, to assess tissue stiffness; Tissue Harmonic and Inverted Pulse; Memory for review of M-Mode images or Doppler Spectrum; Hard disk of min. 500GB; Function cine: storage of static frames (two-dimensional and color); Ability to record images and reports on hard disk and DVD, with the possibility of exporting images; DICOM 3.0; Simultaneous and active connection for min. Three transducers (not withConsidered the tipocaneta transducer or blind Doppler as active connection). Software included: Cardiology (adult, pediatric, neonatal and transesophageal) software; 2D image plane electronic angulation without transducer rotation; Real-time acquisition in Live 3D mode; Optimized zoom;Software to measure myocardial velocity and strain rate along user-defined lines; Multiplanar reconstructions (MPR) for unlimited 3D volume anatomical planes; Tools for automatic detection of three-dimensional image planes; Software for studyOf resynchronization; Composition of image that allows analysis of structure from several angles; Automatic measurements of the thickness of the intima-media layer in the arteries and other superficial vessels; Processing that allows real-time 3D bi-dimensionalM as the Cardiac Flow; Specific software for automated 2D and 3D quantification of mitral valve anatomy and associated structures based on data acquired with Live 3D mode and 3D transesophageal transducer; Visualization of multiplanar reconstruction and tomographic sections. Display and manipDimensional rendering and LV volumes; Two-dimensional image quantification software (Strain / Strain-rate, Speckle Tracking); Integrated stress echo software with at least three protocols (exercise and pharmacological) of the exam containing at leastS six stages of acquisition (baseline, low dose, mean dose, maximum dose, maximum frequency, additional atropine and rest); Contrast examination software; Software for quantification of transthoracic three-dimensional exams (global and regional LV volume, volume curves of seventeen regions)As standardized by the ASE); Tools for automatic detection of planes in three-dimensional images; Software for resynchronizat...
Documents
Tender Notice