Replies should be sent by 19 October 2026, 1:00 pm Eastern Starndard Time to:
Mr. Iran Walker, Email:
[email protected]The U.S. Coast Guard is looking for sources which would be interested in performing Drydock Repairs for Coast Guard Cutter WILLIAM TATE (WLM 560)
USCGC WILLIAM TATE (WLM 560) HOMEPORT ADDRESS: 1 Washington Avenue, Philadelphia, PA. 19147
ANTICIPATED PERIOD OF PERFORMANCE: April 6, 2027, to August 4, 2027 (Subject to change)
PLACE OF PERFORMANCE: Contractor Facility
The scope of this acquisition is for the dockside repairs of various work items for USCGC WILLIAM TATE (WLM 560). The work will include, but is not limited to:
Fire Prevention Requirements
Hull Plating, U/W Body, Inspect
Hull Plating, U/W Body, Ultrasonic Testing
Hull Plating, Freeboard, Ultrasonic Testing
U/W Body, Preserve, 100 percent
U/W Body, Preserve, Partial, Condition B
Appendages, U/W, Leak Test
Chain Lockers, Clean and
Tanks, MP Fuel Stowage and Overflow, Clean and Inspect
Tanks, MP Fuel Service, Clean and Inspect
Tanks, Ballast, Clean and Inspect
Tanks, Dirty Oil and Waste, Clean and Inspect
Hydraulically Operated Cargo Hatch, Inspect and Service
Z-Drive Propulsion Unit, Renew, Drydock
Fathometer Transducer, Renew
Underwater Speed Log, Transducers, Renew
Sea Valves and Waster Pieces, Overhaul or Renew
Sea Strainers, Duplex, All Sizes, Overhaul
Sea Bay, Clean and Inspect
Thruster Unit (General), Overhaul
Thruster Unit Bearings, Renew
Hull Fittings (Weight Handling Rigging Hardware), Inspect and Test
Hydraulic Chain Stoppers, Inspect and Service
Hydraulic Crossdeck Winches, Inspect and Service
Hydraulic Inhaul Winch, Inspect and Service
Mechanical Chain Stoppers, Inspect and Service
Anchor Windlass, Inspect and Service
Anchor Chains and Ground Tackle, Inspect and Repair
Warping Capstan (Aft), Inspect and Service
Single Point Davit, Disassemble and Inspect
Buoy Cr...