HOMELAND SECURITY, DEPARTMENT OF has floated a tender for Uscgc Stratton Chill Box Evap Nr1 Leak. The project location is USA and the tender is closing on 08 May 2024. The tender notice number is 70Z08524P0004754, while the TOT Ref Number is 100835574. Bidders can have further information about the Tender and can request the complete Tender document by Registering on the site.

Expired Tender

Procurement Summary

Country : USA

Summary : Uscgc Stratton Chill Box Evap Nr1 Leak

Deadline : 08 May 2024

Other Information

Notice Type : Tender

TOT Ref.No.: 100835574

Document Ref. No. : 70Z08524P0004754

Competition : ICB

Financier : Self Financed

Purchaser Ownership : Public

Tender Value : Refer Document

Purchaser's Detail

Purchaser : HOMELAND SECURITY, DEPARTMENT OF
Contracting Office Address : ALAMEDA, CA 94501
Primary Point of Contact : KYLER FISK
KYLER.C.FISK@USCG.MIL
Phone Number 9492881271

Secondary Point of Contact : BRENDEN COX
BRENDEN.S.COX@USCG.MIL
Phone Number 12068315347
USA
Email :kyler.c.fisk@uscg.mil

Tender Details

Description

General Requirements1. SCOPE1.1 Intent. This standard specification invokes general requirements for conducting vessel repairs performed by commercial contractors at a Coast Guard facility for Coast Guard vessels.2. REFERENCESCOAST GUARD DRAWINGSNoneCOAST GUARD PUBLICATIONSSurface Forces Logistics Center Standard Specification 0000 (SFLC Std Spec 0000), 2022, General RequirementsSurface Forces Logistics Center Standard Specification 0740 (SFLC Std Spec 0740), 2022, Welding and Allied ProcessesSurface Forces Logistics Center Standard Specification 5550 (SFLC Std Spec 5550), 2022, Fire Prevention and ResponseOTHER REFERENCESNone3. REQUIREMENTS3.1 General. The Contractor must conform to all requirements specified in SFLC Std Spec 0000 and in this item, as applicable, during the performance of this availability. The requirements of this WI applies to all work under the scope of this contract, whether explicitly stated in all following work items or not, and to all other work subsequently authorized by changes, modifications, or extensions to the contract.3.2 Contractor-provided fire watch personnel. The Contractor must provide fire watch personnel and equipment.3.3 Welding and brazing requirements. The Contractor must perform all welding and allied processes, and NDE in accordance with SFLC Std Spec 0740.3.4 Fire Prevention Specification. The Contractor must submit a Fire Prevention Plan in accordance with paragraph 3.1 of SFLC Standard Spec 55503.5. Period of Performance. The period of performance for this work starts on 8 April 2024 and ends on 30 April 2024.3.1.6. Location. The Contractor must perform the work while the USCGC STRATTON (WMSL 752) is alongside the pier at Coast Guard Island, Alameda, CA 94501.

Discrep_51600_BJA_0424_752WORK ITEM 1: Refrigeration Plant, Leak Test1. SCOPE1.1 Intent. This work item describes the requirements for the Contractor to test for leaks in the ship-s stores refrigeration system.TABLE 1 - REFRIGERATION PLANT NA...
Active Contract Opportunity Notice ID 70Z08524P0004754 Related Notice Department/Ind. Agency HOMELAND SECURITY, DEPARTMENT OF Sub-tier US COAST GUARD Office SFLC PROCUREMENT BRANCH 2(00085)
General Information
Contract Opportunity Type: Combined Synopsis/Solicitation (Original)
All Dates/Times are: (UTC-07:00) PACIFIC STANDARD TIME, LOS ANGELES, USA
Original Published Date: May 03, 2024 09:36 am PDT
Original Date Offers Due: May 08, 2024 08:00 am PDT
Inactive Policy: 15 days after date offers due
Original Inactive Date: May 23, 2024
Initiative: None

Classification
Original Set Aside:
Product Service Code: J020 - MAINT/REPAIR/REBUILD OF EQUIPMENT- SHIP AND MARINE EQUIPMENT
NAICS Code: 336611 - Ship Building and Repairing

Place of Performance: Alameda, CA 94501 USA

Documents

 Tender Notice

51600_RfrigrtnPlntSystmleak_418.docx