Procurement Summary
Country: Kuwait
Summary: Turbo Pumping Station for High Vacuum Application Air Cooled Type System
Deadline: 08 Dec 2015
Posting Date: 26 Nov 2015
Other Information
Notice Type: Tender
TOT Ref.No.: 4466249
Document Ref. No.: 2151600623
Competition: ICB
Financier: Self Financed
Purchaser Ownership: -
Tender Value: Refer Document
CPV Classification
42512000 - Air-conditioning installations
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_details
Login to see detailsTender Details
Quotation are Invited for Turbo Pumping Station for High Vacuum Application.. (1) Air Cooled Type System Should be Integrated with Turbo Pump. (2) Integrated Dry Diaphragm Backing Pump and Control Electronics. (3) Should be Ready for Vacuum Operation. (4) Should be Dn 40 Iso-Kf Flange & Display Control Unit (Dcu). (5) Diaphragm Backing Pump Speed of 3.8 mtr.cube/Hr at 50hz. (6) Turbo Pump Speed Should be between 30-40 Litters Per Second (7) Ultimate Pressure Should be Less than 1*10-7 Hpa. (8) System Should be Compact and Total Weight Less than 50 Kg. (9) Controls for the Backing Pump Integrated with the System Itself. (10) Pump Down Time for 10 Litter Vacuum Chamber Should be Less than 60 Seconds (11) Should Include 1e-4 to 1200 Hpa Gauge, Control and Power Supply Unit, Gauge Cables and Power Chord. (12) Should Provide Additional Gauge and Display to Measure 1e-6 Vacuum (13) Original Catalogue from Manufacturer Should be Provided, Qty 1, Precision Translation Stage, 306 Mm Travel Length. . (1) Should Have Active Drive Dc Motor. (2) Linear Encoder Integrated Sensor Resolution 0.02 Micro Meter. (3) Minimum Incremental Motion 0.1 Micro Meter. (4) Pitch Should be +/- 35 Micro Radian. (5) Straightness Should be Minimum 1 Micro Meter. (6) Maximum Velovity Should be 50mm/S. (7) Maximum Load Capacity Should be 1000n. (8) Motor Operating Voltage 24 Pwm Volts. (9) Limit and Reference Switches Should be Hall-Effect. (10) Material Should be Black Anodized Aluminium. (11) Should Have Unidirectional Repeatability 0.1 Micro Meter. (12) Spindle Pitch 2 Mm. (13) Maximum Push/Pull Force Should be 80 N. (14) Maximum Lateral Force Should be 200 N. (15) Original Catalogue from Manufacturer Describing the Products Detailed Specification Must be Provided with the Offer Document. (16) Items (2 & 3) Should be from Same Manufacturer for the Dc Motor Drives to be Compatible with the Moving Stages, Qty 1, Mercury Dc Motor Controller Compatible for Precision Translation Stages for Item (2). . (1) Single Channel for Controlling Translation Stages. (2) Servo Characteristics Should be Pid. (3) Servo Cycle Time Should be 50 Micro Seconds. (4) Profile Generator Should be Trapezoid Velocity Profile. (5) Limit Switches 2 Nos of Ttl and One Reference Point Ttl Switch. (6) Should Have Software Controlled Ttl Motor Brake. (7) I=2a and Output Voltage 0 to A+/-15v for Direct Control of Dc Motor. (8) Maximum Output Power Should be 30w. (9) Controller Should Have Usb, rs232 and Sub-d9 Pin Interfaces. (10) Should Have Input/Output Ports. (11) Should Provide Detailed Communication Commands. (12) User Friendly Software to Control the Motor, Software Drivers. (13) Should Have Analog/Digital Input/Output Ports with 5 Volts Ttl. (14) Should Include I/O Cable and rs232 Cable and All Needed Cables for the Mercury Controller. (15) Should Provide a Separate Manual Control Box or Joystick to Control the Translation Stages Manually. (16) Original Catalogue from Manufacturer Describing the Products Specification Should be Provided with the Offer Document. (17) Items (2&3) Should be from Same Manufacturer for Compatibility of Programs & Instructions of Translation Stages with the Mercury Dc Motor Controller, Qty 1, Turbo Pumping Station for High Vacuum Application. . (1) Air Cooled Type System Should be Integrated with Turbo Pump. (2) Integrated Dry Diaphragm Backing Pump and Control Electronics. (3) Should be Ready for Vacuum Operation. (4) Should be Dn 40 Iso-Kf Flange & Display Control Unit (Dcu). (5) Diaphragm Backing Pump Speed of 0.50 mtr.cube/Hr at 50hz. (6) Pumping Speed for Nitrogen Should be 35 L/S. (7) Ultimate Pressure Should be Less than 1*10-7 Hpa. (8) System Should be Compact and Total Weight Less than 20 Kg. (9) Controls for the Backing Pump Integrated with the System Itself. (10) Should be Suitable for Dry and Oil Free Vacuum Applications. (11) Sound Level of the Backing Pump Should be Less than 60 Db. (12) the Complete System Should be Plug and Play. (13) Should Include 1e-4 to 1200 Hpa Gauge, Control and Power Supply Unit, Gauge Cables and Power Chord. (14) Display Control Unit with Integrated Gauge Connection. (15) Original Catalogue from Manufacturer Should be Provided, Qty 1, Laser Driven Light Source . (1) Should Have Spectral Output from 170 Nm to 2100 Nm. (2) Typical Bulb Life Should be Greater than 9000 Hours. (3) Should be Water Cooled and Portable Chiller with External 5 Mocron Liquid Filter Should be Provided. (4) Electrical Specification Compatible with 240 Vac. (5) Should be Cw Laser Plasma Discharge Type. (6) Should be Working without Electrodes (7) System Should Work with Water Cooling (8) Lamp House and Power Supply Should be Separate (9) Numerical Aperture(Na) Should be up to 0.50 (10) Should Provide Coupling Optics to Make the Beam Parallel and Collimated (11) Optical Interface Must be Compatible with Free Space or Fiber (12) Original Catalogue from Manufacturer with Detailed Specification Should be Provided with the Offer Document, Qty 1. RFQ Fees: KD 75/-.
Documents
Tender Notice