Expired Tender France ICB TOT Ref. 40923777

This consultation involves the replacement Tender - 40923777

Tender notice from France, published on 25 Feb 2020.

Executive Summary

The STATE OPERATORS has issued a Tender notice for the procurement of a This consultation involves the replacement of the 218 bank battery simulator with new equipment with a power of 250 kW. The main characteristics to be satisfied for this battery simulator are the foll... in the France. This Tender notice was published on 25 Feb 2020 and is scheduled to close on 30 Mar 2020, with an estimated Tender value of Refer Document. Interested bidders can access detailed Tender information, eligibility criteria, and complete bidding documents by referencing TOT Ref No. 40923777, while the tender notice number is 440170-20-TEC-RUE and Register on the platform.

Key facts

Summary
This consultation involves the replacement of the 218 bank battery simulator with new equipment with a power of 250 kW. The main characteristics to be satisfied for this battery simulator are the foll...
TOT Ref. No.
40923777
Document Ref. No.
440170-20-TEC-RUE
Country
France
Notice type
Tender
Competition
ICB
Publication date
25 Feb 2020
Bid deadline
30 Mar 2020
EMD
Refer Document
Tender value
Refer Document
Purchaser ownership
-
Financier
Self Financed

CPV classification

Purchaser details

Purchaser contact is for registered users

Login to see details

Tender details

This consultation involves the replacement of the 218 bank battery simulator with new equipment with a power of 250 kW. The main characteristics to be satisfied for this battery simulator are the following: • Maximum permanent current of / - 800A, • Option 1: Voltage rangeon adjustable from 5 to 800V, • Option 2: Voltage range adjustable from 5 to 1000V, • Operation in 2 quadrants, reversible in current, • Maximum continuous power of 250 kW in load mode as in generator mode, • Adjustable limitation in piloting external voltage, current and powere. • In charge mode, the power will be fed back to the 400VAC three-phase network. • Compensation up to the voltage drop in the power cables going from the battery simulator cabinet to the inverter installed in the test bench, up to 5% of nominal U. • Galvanic isolation betweenre the three-phase network and use must imperatively be ensured. • The DC output must be isolated from the equipotential protection. • Consequently, the cabinet must integrate a permanent insulation controller conforming to standard EN 61557-8 on the DC power supply. The detection of a leak atthe earth must cause the battery simulator to be immediately shut down with the fault reported to the IFPEN control system. • The cabinet must be equipped on the DC output with power contactors capable of carrying out a load cut-off. • The battery simulator should iIntegrate the following protections: overload and short circuits at DC output; thermal protection of power components and internal temperature monitoring. • The cabinet must integrate a user-friendly HMI with graphic display on the front panel. This GUI should display the mainbattery simulator information and allow access to all configuration and status parameters, with password protection for sensitive parameters. The GUI should be able to display the timestamped history of different events such as changes of state andfauts.
Subject :This consultation involves the replacement of the 218 battery simulator with new equipment with a power of 250 kW. The main characteristics to be satisfied for this battery simulator are the following: • Maximum permanent current of / - 800A, • Option 1: Voltage rangeadjustable from 5 to 800V, • Option 2: Voltage range adjustable from 5 to 1000V, • Operation in 2 quadrants, reversible in current, • Maximum continuous power of 250 kW in load mode as in generator mode, • Adjustable limitation in external control of voltage, current and power.load mode the power will be fed back into the three-phase 400VAC network • Compensation until the voltage drop in the power cables going from the battery simulator cabinet to the inverter installed in the test bench, up to 5% of nominal U. • Galvanic isolation between the resthree-phase water and use must be ensured • The DC output must be isolated from the equipotential protection. • Consequently, the cabinet...

Documents

Tender Notice
Login to view

Similar tenders

France Public Procurement Intelligence

Frequently asked questions

The bid deadline for This consultation involves the replacement of the 218 bank battery simulator with new equipment with a power of 250 kW. The main characteristics to be satisfied for this battery simulator are the foll... was 30 Mar 2020. Bidding is closed.

This tender has been issued by STATE OPERATORS in France.

The tender value is not disclosed; please refer to the tender document. EMD / bid security details are provided in the tender document.

This tender is Self Financed

The tender is classified under the following CPV code(s): 38970000 - Research, testing and scientific technical simulator.

The tender notice and related documents are listed in the Documents section above. Select a document to view or download it. Please log in or register to access the documents. If you cannot find additional documents in the Documents section, please log in to your account and Send Document Request from your account section.

The TendersOnTime reference is 40923777. The purchaser document reference is 440170-20-TEC-RUE.

See the Similar Tenders section on this page or browse other tenders from France.

This tender falls under Technology and Equipment in France. Suppliers in these sectors can track similar France tenders using CPV-based alerts.