Supply of Portable Autoclave Tender in Kuwait - 3175988
Tender notice from Kuwait, published on 30 Jun 2015.
Executive Summary
The KUWAIT UNIVERSITY has issued a Tender notice for the procurement of a Supply of Portable Autoclave in the Kuwait. This Tender notice was published on 30 Jun 2015 and is scheduled to close on 14 Jul 2015, with an estimated Tender value of Refer Document.
Interested bidders can access detailed Tender information, eligibility criteria, and complete bidding documents by referencing TOT Ref No. 3175988, while the tender notice number is 2151600248 and Register on the platform.
Quotation are invited for Portable autoclave. Virtical Autoclave 31 L The system should come with Advanced Control System and state-of-the-art Control System with Multi-Color Display -c Fo software control -c PID (Proportional Integral Differential) pressure control -c Stores the last 200 cycles in built-in memory -c Two PT100 sensors according to IEC61010-1, IEC 61010-2-040 -c Up to 6 temperature sensors and 4 pressure sensors can be connected -c 30 Identification Codes and Passwords for access level control -c The controller and software comply with the 21 CFR part 11 standard A safety device prevents the operator from opening the door when the chamber is pressurized Steam is not allowed to enter the chamber when the door is open A cycle cannot start if the door is open or not properly locked The door cannot unlock until liquid temperature reaches the predetermined end temp The door cannot unlock until chamber pressure reaches room pressure Temperature Activated Door Lock - The door will not open until the temperature is below a specified safe level Chamber Volume (in Liters) 31 It should come with following accessories SS Wire basket, SS Container with vent holes The autoclaves should comply with the strictest international directives and standards "Pressure Vessel and Steam Generator Construction Standards: -c ASME Code, Section VIII, Division 1, Unfired Pressure Vessels -c ASME Code, Section I, for Boilers -c EN 13445:2009 for Pressure Vessels -c EN14222:2003 and EN 12953 for Steam Boilers" "Safety and EMC Standards: -c IEC/UL/EN 61010-1, IEC 61010-2-040, EN 61326" Sterilization: DIN 58951 Series, ISO 17665-1:2006 Quality System: ISO 9001:2000, ISO 13485:2003 -c 21 CFR 820. Qty 1, Micro balance. ANALYTICAL/SEMI-MICRO BALANCE Internal Calibration Mass with Large Breeze Break and Compact Footprint 0.01mg Semi-Micro Resolution Internal Calibration Standard Full Digital Calibration User Friendly Operation Liquid Crystal Display RS-232C Bi-directional Interface Balance ID Number Specifications Weighting Capacity : 310 g X 0.0001 Counting Min. Weighing Value (1 digit) 0.1 mg Repeatability (standard deviation) : 0.0001 g Linearity: A+/-0.0002 g Stabilization time : 3.5 sec " Sensitivity drift (10AC - 30AC) Ambient temperature : A+/- 2 ppm/AC (Automatic Self Calibration is not used)" Display Refresh : 5 times per second / 10 times per second Operating Temperature : 5AC - 40AC RH 85% weighing pan : ? 85 mm / 3.3 inches min. unit weight : 0.1 mg min 100% weight : 0.01 g calibration weight : built- in weight external calibration weight : 200 g / 300 g. qty 1, rotatory evaporator.qty 1, freeze dryer. "performance data " drying in round bottom flasks: maximum 8 pieces "ice condenser capacity: max. 2.5kg " " ice condenser performance max. 2kg/24h " ice condenser temperature1) approx. -55ac maximum ambient temperature (unit is air-cooled, higher temperatures upon request) climate category sn +10ac to +32ac "max. shelf surface area when drying outside the ice condenser chamber : 3 shelves, ?200 atotal 0.092m2 spacing: up to 80mm with accessory no. 120893 " "max. shelf surface area when drying in glass vials with sealing under vacuum or nitrogen atmosphere outside the ice condenser chamber: 2 shelves, ?200 aotal 0.054m2 spacing: 25-70mm with accessory no. 121015" "noise emissions according to din 45635: 49 db(a) " shelf temperature, when pre-freezing inside the ice condenser chamber approximately -25ac it should include vacuum pump suitable with the above specifications. qty 1, centrifuge. auto-lock iii rotor system 1. installation and exchange of rotors with just the push of a button for quick switch between applications 2. easy chamber access enables cleaning convenience, reducing contamination risk and leading to improved research and a healthier working environment click seal bucket sealing system innovative biocontainment solution provides: 1. simple operation eliminating screw caps and complicated clips 2. glove-friendly, one-handed open/close capability "3. biocontainment certification by hpa, porton down, uk (formerly camr)." 4. transparent and biocompatible polyetherimide (pei) sealing covers have broad chemical resistance, excellent thermal properties and exceptional strength for durability motorized lid latch "1. one finger downward motion for easiest closing and locking - even on tall benches" 2. automatic lid opening at end of run smart spin technology 1. dynamic technology improves safety and run results by considering chamber temperature, rotor and bucket combination and selected speed to auto-correct maximum rotor speed, calibrate the imbalance detector and optimize motor power during acceleration and braking fiberlite carbon fiber rotors "1. maximize centrifuge performance with increased capacity, faster speeds and higher g-force" 2. corrosion free, lightweight and fatigue-resistance 3. naturally insulating properties ensure samples are kept at a constant temperature during centrifugation 4. 15-year warranty for fiberlite rotors specifications 1. swinging bucket rotors * max. capacity 4 x 400 ml (with tx-400 rotor) * max. capacity 4 x 400 ml (with tx-400 rotor) * max speed 5500 rpm (with tx-200 rotor) * max rcf 5580 x g (with tx-200 rotor) 2. fixed angle rotors * max capacity 6 x 100 ml (with f15-6x100 rotor) * max speed 15200 rpm (with 30x2 ml rotor) * max rcf 25830 x g (with 30x2 ml rotor) 3. control system microprocessor 4. drive system direct, brushless induction low profile motor 5. rotor locking system : auto lock iii 6. imbalance detection system : smart spin 7. programs : 6, direct access 8. temperature set range : -10ac and +40ac 9. pre-cooling function :yes, with direct button 10. refrigeration system: cfc free 11. pulse (short) run: yes 12. acceleration / deceleration rates : 9/10 13. centrifugation chamber: stainless steel 14. max. timer range: 9h, 99min + continuous 15. pre-temp: (refrigerated unit) achieve 4ac from ambient 23ac in 15 minutes 16. noise level 61dba 17.should supply 4 sets of adapters for fixed angle rotors15ml and 50ml. qty 1. document fee: kd 75.000/-.
The bid deadline for Supply of Portable Autoclave was 14 Jul 2015. Bidding is closed.
This tender has been issued by KUWAIT UNIVERSITY in Kuwait.
The tender value is not disclosed; please refer to the tender document. EMD / bid security details are provided in the tender document.
This tender is Self Financed
The tender is classified under the following CPV code(s): 33191110 - Autoclaves.
The tender notice and related documents are listed in the Documents section above. Select a document to view or download it. Please log in or register to access the documents. If you cannot find additional documents in the Documents section, please log in to your account and Send Document Request from your account section.
The TendersOnTime reference is 3175988. The purchaser document reference is 2151600248.