Supply of Laboratory Equipment of COE-ME for CHED Tender - 7521015
Tender notice from Philippines, published on 29 Jul 2016.
Executive Summary
The MINDANAO STATE UNIVERSITY - ILIGAN INSTITUTE OF TECHNOLOGY has issued a Tender notice for the procurement of a Supply of Laboratory Equipment of COE-ME for CHED CMO compliance in the Philippines. This Tender notice was published on 29 Jul 2016 and is scheduled to close on 16 Aug 2016, with an estimated Tender value of Refer Document.
Interested bidders can access detailed Tender information, eligibility criteria, and complete bidding documents by referencing TOT Ref No. 7521015, while the tender notice number is 2016-076 and Register on the platform.
Key facts
Summary
Supply of Laboratory Equipment of COE-ME for CHED CMO compliance
1 XRD and XRF system including 1-unit XRD specfications: * capable of qualitative and quantitative analysis, crystallographic analysis and research application for minerals, mining, geology applications, low resolution thin films analysis (is optional but considered), analysis of powder samples and small sample analysis provision for thin films analysis attachment Automatic door interlock X-ray radiation safety mechanism Automatic X-ray off after sample analysis for longer xray lifetime Overload, overvoltage overcurrent, cooling water abnormality tube protection Warning light located on the top of the radiation source or Electromagnetic shutter interlocked with radiation enclosure Side heating temperature furnace 1, 500 deg including temp controller & vacuum pump and control can be interfaced with the computer Provision of spare parts and technical services on-site, free of charge within the warranty period and to be continued under the Service Contract Agreement at cost on a yearly basis. Flexible optics and easy upgrade stage combinations to handle wide range of attachments such as sample heater, stress analysis, etc. HAS PROVISION FOR Manual measurement: manual operation of all axes and detector UNIVERSAL CONTROLLER (PC controlled): detector high voltage:0 - 1500V;;; pulse height analyzer:baseline and window setting;;; linearity: 700, 000 cps with dead time correction Automatic alignment: automated alignment of each of the goniometer and attachment axes as well as setting of the detector PHA, HV and dead time correction multiple recording:multiple plot of raw data files; integrated intensity calculation displays real-time results, measurement condition and editing settings conversion (raw data- text-compatible with Microsoft office) safety features: leak current breaker, abnormal generator overload detection, abnormal cooling water flow, pressure and temperature detection, shutter malfunction detection. SAMPLE HOLDERS: 20 pcs: Al, glasS 0.5mm and glass 0.2 mm SCINTILLATION COUNTER: PREFERABLY NaI) POWER SUPPLY: compatible with Philiippine settings e.g. 220VAC, 20A, 60Hz Single phase A A GENERATOR: 3kW Cu;20 -60kV, 1kV steps;2-60mA, 1mA steps;A+/-0.01% against A+/-10%mains fluctuation, voltage and current A X-RAY TUBE: 1 set 2.7kW, Cu-target A FILTER: Ni Filter for Cu-target X-ray tube A GONIOMETER: DIVERGENCE SLIT:0.01mm step; 0.05- 7mm Scattering prevention slit: 0.01 mm step; 0.05 - 7mm RECEIVING SLIT: 0.05-7mm; 0.01 mm step height slits: 2.0 - 5.0 mm. OPEN SCANNING RANGE: -3 TO + 162 O (2I) Fully automatic goniometer optical system with automatic saving of adjustment of data Vertical (I - I)configuration Goniometer radius: 285mm Scanning method:I/2 I linked, I, 2I independent scan speed:0.02 to 100o /min (2 I) Angular reproducibility: A+/-0.0002 o A SOFTWARE: Smoothing, basic data reduction BG deletion, KI+/-1 - KI+/-2 separation, peak search (basic data reduction and peak search), width at half height, system correction, internal/external standard correction, qualitative/identification analysis, quantitative/calibration curve analysis, user database creation, auto search and match, data format conversion standard measurement: I / 2I A RECEIVING MONOCHROMATOR: Graphite monochromator for copper: diffracted beam monochromator type;monochromator slit:0.80 mm A COOLING SYSTEM: For the X-ray tube to ensure cool, pure and clean water circulation and need not use tap water and piping connection to local water supply Single phase 200V A A ICDD DATABASE: Licensed PDF-2 database (inclusive of PDF-1) and PDF-1/PDF-2 Retrieval software for windows for automatic search software on multiple elements using -A"AND-A
The bid deadline for Supply of Laboratory Equipment of COE-ME for CHED CMO compliance was 16 Aug 2016. Bidding is closed.
This tender has been issued by MINDANAO STATE UNIVERSITY - ILIGAN INSTITUTE OF TECHNOLOGY in Philippines.
The tender value is not disclosed; please refer to the tender document. EMD / bid security details are provided in the tender document.
This tender is Self Financed
The tender is classified under the following CPV code(s): 38000000 - Laboratory, optical and precision equipments (excl. glasses).
The tender notice and related documents are listed in the Documents section above. Select a document to view or download it. Please log in or register to access the documents. If you cannot find additional documents in the Documents section, please log in to your account and Send Document Request from your account section.
The TendersOnTime reference is 7521015. The purchaser document reference is 2016-076.
This tender falls under Technology and Equipment in Philippines. Suppliers in these sectors can track similar Philippines tenders using CPV-based alerts.