Description of Required Product or Service British Columbia Hydro and Power Authority ("BC Hydro") requires the supply and delivery of Ductile Iron Articulated Split-Pipe for submarine cable support. The Ductile Iron Articulated Split-Pipe must meet the following minimum requirements: 1. The split-pipe design shall ensure physical protection of submarine cables installed in saltwater, in high wave energy areas, in sub-tidal zones, in areas where sediment mobility can expose buried cables 2. The split-pipe sections shall connect and interlock by hook and pin arrangement and articulated /by ball and socket connection that allows a flexible connection but restrict cable bending to at least 1.5 m. The two parts shall be identical 3. Shall fit on a cable with 66 mm diameter 4. The split pipe shall have a minimum wall thickness of 9 mm 5. The split pipe shall be made from Spheroidal Graphite Cast Iron ISO 1083 with: a. Minimum tensile strength of 400 N/mm2 b. Yield point (minimum) 200 N/mm2 c. Minimum elongation at break of 15% 6. The manufacturer shall have completed the following type tests: a. Bend test 15 ton b. Crush test 15 ton c. Impact resistance: 12 m drop test of 26 kg d. Brinell hardness, and e. chemical composition. 7. Stainless steel SS316 bolts, washers nuts to be included at least for every 5 m 8. Maximum section length 0.5 m 9. Minimum expected life in the environment detailed at point 1: 20 years Proposed Contract Award Notice is hereby given by BC Hydro and Power...
Solicitation Type : NOI - Notice of Intent (Informal)
Reference Number : 00004742097
Location : British Columbia
Purchase Type : Not Stated
Dates Publication : 2025/10/03 06:56:00 AM EDT
Closing Date : 2025/10/08 02:00:00 PM EDT
Contact Information : Lisa Gahir
:
[email protected]:
Description : Description of Required Product or Service British Columbia Hydro and Power Authority ("BC Hydro") requires the supply and delivery of Ductile Iron Articulated Split-Pipe for submarine cable support. The Ductile Iron Articulated Split-Pipe must meet the following minimum requirements: 1. The split-pipe design shall ensure physical protection of submarine cables installed in saltwater, in high wave energy areas, in sub-tidal zones, in areas where sediment mobility can expose buried cables 2. The split-pipe sections shall connect and interlock by hook and pin arrangement and articulated /by ball and socket connection that allows a flexible connection but restrict cable bending to at least 1.5 m. The two parts shall be identical 3. Shall fit on a cable with 66 mm diameter 4. The split pipe shall have a minimum wall thickness of 9 mm 5. The split pipe shall be made from Spheroidal Graphite Cast Iron ISO 1083 with: a. Minimum tensile strength of 400 N/mm2 b. Yield point (minimum) 200 N/mm2 c. Minimum elongation at break of 15% 6. The manufacturer shall have completed the following type tests: a. Bend test 15 ton b. Crush test 15 ton c. Imp...