Expired Tender USA ICB TOT Ref. 108363657

Sources Sought Notice - Steam Pipe Repair Tender in USA - 108363657

Tender notice from USA, published on 09 Oct 2024.

Executive Summary

The VETERANS AFFAIRS, DEPARTMENT OF has issued a Tender notice for the procurement of a Sources Sought Notice - Steam Pipe Repair and Replacement Perry Point Va Medical Center - 512-25-1-663-0001 in the USA. This Tender notice was published on 09 Oct 2024 and is scheduled to close on 21 Oct 2024, with an estimated Tender value of Refer Document. Interested bidders can access detailed Tender information, eligibility criteria, and complete bidding documents by referencing TOT Ref No. 108363657, while the tender notice number is 36C24525Q0031 and Register on the platform.

Key facts

Summary
Sources Sought Notice - Steam Pipe Repair and Replacement Perry Point Va Medical Center - 512-25-1-663-0001
TOT Ref. No.
108363657
Document Ref. No.
36C24525Q0031
Country
USA
Notice type
Tender
Competition
ICB
Publication date
09 Oct 2024
Bid deadline
21 Oct 2024
EMD
Refer Document
Tender value
Refer Document
Purchaser ownership
Public
Financier
Self Financed

Purchaser details

Purchaser contact is for registered users

Login to see details

Tender details

Description
SUMMARY: Department of Veterans Affairs, Veterans Health Administration, Network Contracting Office 5, is issuing this request for sources sought notice in order to identify vendors that are interested in and capable of providing contractor services. For a contractor that can supply all labor, material, and equipment to repair Steam Piping located at the Perry Point VAMC. Description of Work: Project Data: Title: Steam Piping Repair and Replacement Facility: Perry Point VA Medical Center 361 Boiler House Rd, Perry Point, MD 21902 General Scope: The contractor shall provide all supervision, labor, materials, and equipment to remove and replace damaged steam piping and retired piping in steam pit. Perform atmospheric testing prior to entering the steam pit. Dewater the steam pit. Establish continuous positive air flow inside of the steam pit. Determine the location and extent of the steam leak. Remove and replace existing steam trap and associated piping. The new steam trap shall be an Armstrong 883 Inverted Bucket Trap rated for 150 psi or equivalent. The new steam trap piping shall include blowdown, inlet, and outlet gate valves. The new steam trap piping shall include a check valve. The new steam trap shall have a strainer. The new steam trap piping shall include a test valve. Replace existing 8-inch butterfly valve with new appropriate 8-inch gate valve. Replace/repair the thread-o-let fittings on the leaking steam line. Insulate new piping with appropriate insulation. The steam trap and associated piping shall not be insulated. Install and connect sump pump and relocate sump pit to the front right corner when viewed from the ladder. The new sump pump shall be 120 AC Volts, ½-HP and at least 15-ft of max head. Remove and cap retired in place piping in the steam pit. Provide a manhole piping plan and piping details for the new trap assembly to show the newly installed accessories (strainer, check valve, test valve, etc.). Remove all demolition wast...
Active Contract Opportunity

Notice ID : 36C24525Q0031

Related Notice

Department/Ind. Agency : VETERANS AFFAIRS, DEPARTMENT OF

Sub-tier : VETERANS AFFAIRS, DEPARTMENT OF

Office: 245-NETWORK CONTRACT OFFICE 5 (36C245)

General Information

Contract Opportunity Type: Sources Sought (Updated)

Updated Published Date: Oct 08, 2024 01:53 pm EDT

Original Published Date: Oct 08, 2024 11:58 am EDT

Updated Response Date: Oct 21, 2024 12:00 pm EDT

Original Response Date: Oct 21, 2024 12:00 pm EDT

Inactive Policy: Manual

Updated Inactive Date: Dec 20, 2024

Original Inactive Date: Dec 20, 2024

Initiative: None
Classification

Original Set Aside:
Product Service Code: J044 - MAINT/REPAIR/REBUILD OF EQUIPMENT- FURNACE, STEAM PLANT, AND DRYING EQUIPMENT; NUCLEAR REACTORS

NAICS Code: 561210 - Facilities Support Services
Place of Performance: Department of Veterans Affairs Perry Point VA Medical Center Perry Point, MD 21902 USA

Documents

Tender Notice
Login to view
36C24525Q0031.pdf
Login to view
WAGE-DETERMINATION-2016-4215-PP-VAMC.pdf
Login to view

USA Public Procurement Intelligence

Frequently asked questions

The bid deadline for Sources Sought Notice - Steam Pipe Repair and Replacement Perry Point Va Medical Center - 512-25-1-663-0001 was 21 Oct 2024. Bidding is closed.

This tender has been issued by VETERANS AFFAIRS, DEPARTMENT OF in USA.

The tender value is not disclosed; please refer to the tender document. EMD / bid security details are provided in the tender document.

This tender is Self Financed

The tender notice and related documents are listed in the Documents section above. Select a document to view or download it. Please log in or register to access the documents. If you cannot find additional documents in the Documents section, please log in to your account and Send Document Request from your account section.

The TendersOnTime reference is 108363657. The purchaser document reference is 36C24525Q0031.

Browse other tenders from USA or search by relevant keywords and CPV classification.