Expired Tender USA ICB TOT Ref. 120693821

SOURCES SOUGHT NOTICE - Replace 1 PET CT Pump Tender - 120693821

Tender notice from USA, published on 11 Jun 2025.

Executive Summary

The VETERANS AFFAIRS, DEPARTMENT OF has issued a Tender notice for the procurement of a SOURCES SOUGHT NOTICE - Replace 1 PET CT Pump and Rebuild NUMBER 3 HYDRO-TANK PUMP - Washington DC VAMC 688-25-3-459-0273 688-25-3-459-0274 in the USA. This Tender notice was published on 11 Jun 2025 and is scheduled to close on 20 Jun 2025, with an estimated Tender value of Refer Document. Interested bidders can access detailed Tender information, eligibility criteria, and complete bidding documents by referencing TOT Ref No. 120693821, while the tender notice number is 36C24525Q0574 and Register on the platform.

Key facts

Summary
SOURCES SOUGHT NOTICE - Replace 1 PET CT Pump and Rebuild NUMBER 3 HYDRO-TANK PUMP - Washington DC VAMC 688-25-3-459-0273 688-25-3-459-0274
TOT Ref. No.
120693821
Document Ref. No.
36C24525Q0574
Country
USA
Notice type
Tender
Competition
ICB
Publication date
11 Jun 2025
Bid deadline
20 Jun 2025
EMD
Refer Document
Tender value
Refer Document
Purchaser ownership
Public
Financier
Self Financed

Purchaser details

Purchaser contact is for registered users

Login to see details

Tender details

Description
Department of Veterans Affairs, Veterans Health Administration, Network Contracting Office 5, is issuing this request for sources sought notice in order to identify vendors that are interested in and capable of providing contractor services. For a contractor to Replace 1 PET CT Pump and Rebuild NUMBER 3 HYDRO-TANK PUMP for the Washington DC VA Medical Center. Description of Work:Project Number 1Location: Department of Veterans AffairsWashington DC VA Medical Center50 Irving St NWWashington DC, 20422Project Number 688-25-3-459-0273Project: Replacement PET CT Pumps in MER1 (m/n Flowserve SMP 2000)1. Power Disconnection and Lockout/Tagout (LOTO) ProceduresThe contractor shall identify and isolate the electrical power source supplying the existing pump assembly.Power shall be shut off, locked out, and tagged at the electrical panel in full compliance with standard Lockout/Tagout (LOTO) procedures prior to starting any work.The contractor shall coordinate the scheduling work with the Contracting Officer s Representative (COR).The contractor shall isolate the water supply to the pumps by closing the supply valve to the pump. 2. Removal of Existing defective pumpRemove coupling halves from the existing pump.Remove shaft and impeller from the pump housing, replace pump (m/n Flowserve SMP 2000).Reinstall the new insert and bolts on the existing coupling halvesAlin motor to the pump and reinstall cover for coupling.3. System Testing and DemonstrationA complete demonstration of the installed pumps, valves, and control system shall be conducted by the contractor.The system s operational control and sequence of operation shall be reviewed and verified in the presence of the Government representative.The contractor shall not modify or alter the existing pump sequence of operation.A report shall be provided to the COR outlining any issues identified with the controls and/or sequence of operation.6. Site Restoration and Clean-UpAfter installation and testing are com...
Active Contract Opportunity

Notice ID : 36C24525Q0574

Related Notice

Department/Ind. Agency : VETERANS AFFAIRS, DEPARTMENT OF

Sub-tier : VETERANS AFFAIRS, DEPARTMENT OF

Office: 245-NETWORK CONTRACT OFFICE 5 (36C245)

General Information

Contract Opportunity Type: Sources Sought (Original)

Original Published Date: Jun 10, 2025 02:05 pm EDT

Original Response Date: Jun 20, 2025 10:00 am EDT

Inactive Policy: Manual

Original Inactive Date: Aug 19, 2025

Initiative: None
Classification

Original Set Aside:

Product Service Code: J043 - MAINT/REPAIR/REBUILD OF EQUIPMENT- PUMPS AND COMPRESSORS

NAICS Code: 238220 - Plumbing, Heating, and Air-Conditioning Contractors
Place of Performance: Department of Veterans Affairs Washington DC VA Medical Center Washington, DC 20422 USA

Documents

Tender Notice
Login to view
36C24525Q0574.docx
Login to view

USA Public Procurement Intelligence

Frequently asked questions

The bid deadline for SOURCES SOUGHT NOTICE - Replace 1 PET CT Pump and Rebuild NUMBER 3 HYDRO-TANK PUMP - Washington DC VAMC 688-25-3-459-0273 688-25-3-459-0274 was 20 Jun 2025. Bidding is closed.

This tender has been issued by VETERANS AFFAIRS, DEPARTMENT OF in USA.

The tender value is not disclosed; please refer to the tender document. EMD / bid security details are provided in the tender document.

This tender is Self Financed

The tender notice and related documents are listed in the Documents section above. Select a document to view or download it. Please log in or register to access the documents. If you cannot find additional documents in the Documents section, please log in to your account and Send Document Request from your account section.

The TendersOnTime reference is 120693821. The purchaser document reference is 36C24525Q0574.

Browse other tenders from USA or search by relevant keywords and CPV classification.