Regalvanize Power Intake Closure Gate Shaft Grills Tender - 34313105

Tender notice from Philippines, published on 02 Jul 2019.

Executive Summary

The NATIONAL IRRIGATION ADMINISTRATION - MARIIS, DRD has issued a Tender notice for the procurement of a Regalvanize Power Intake Closure Gate Shaft Grills at Elevation 200.25 MASL in the Philippines. This Tender notice was published on 02 Jul 2019 and is scheduled to close on 08 Jul 2019, with an estimated Tender value of Refer Document. Interested bidders can access detailed Tender information, eligibility criteria, and complete bidding documents by referencing TOT Ref No. 34313105, while the tender notice number is PURCHASE REQUEST NO. 218 - 2019 and Register on the platform.

Key facts

Summary
Regalvanize Power Intake Closure Gate Shaft Grills at Elevation 200.25 MASL
TOT Ref. No.
34313105
Document Ref. No.
PURCHASE REQUEST NO. 218 - 2019
Country
Philippines
Notice type
Tender
Competition
ICB
Publication date
02 Jul 2019
Bid deadline
08 Jul 2019
EMD
Refer Document
Tender value
Refer Document
Purchaser ownership
-
Financier
Self Financed

Purchaser details

Purchaser contact is for registered users

Login to see details

Tender details

Regalvanize Power Intake Closure Gate Shaft Grills at Elevation 200.25 MASL
TS - 2 Scope of Work
a. The Contractor shall be responsible for the installation of barricades with complete and visible signage of the open shaft for the Closure Gates after the shaft grills has been removed.
b. The Contractor shall be the solely responsible for the transport of shaft grills from site to galvanizing shop and vice versa. Contractor shall similarly liable for the loss, accidental damage and other risks while handling the shaft grills. Contractor shall also provide the required supporting, holding and other materials needed to transport the shaft grills.
Galvanizing Works
a. Shaft grills shall be hot-dipped galvanized according to the long established, well accepted, and approved standards of the American Society for Testing and Materials (ASTM) and additional relevant standards are provided by the Canadian Standards Association (CSA) and the American Association of State Highway and Transportation Officials (AASHTO).
b. Galvanized items shall be free from uncoated areas, blisters, flux deposits, dross inclusions, and other types of projections that would interfere with the intended use of the shaft grills, or other defects not consistent with good galvanizing practice.
c. The coating shall be continuous and as reasonably smooth and uniform in thickness conform to the Standard specification for zinc (hot-dip galvanized) coatings on iron and steel products (see ASTM A 123/A123M table).
d. Coating thickness measures must be taken several points on each inspected article to comply with ASTM A 123/A123M or Standard specification for zinc (hot-dip galvanized) coatings on iron and steel products
e. The thickness of coating test shall be determined by one or more of the methods described as follows:
1. Magnetic thickness measurement
2. Stripping method
3. Weighing before and after galvanizing
4. Microscopy
5. Referee method
f. The galvanizers have the sole responsibility to ensure compliance with these specifications. This shall achieved by an in-plant inspection program designed to maintain the coating thickness, finish and appearance within the requirements.
g. The Contractor together with the NIA inspectors shall have access at all times to those areas of the galvanizer-s facility which concern the application of the zinc coating is being performed.
h. The galvanizer shall afford the NIA inspector all reasonable facilities to satisfy the inspectors that the zinc coating is being furnished in accordance with the requirements.
i. All shaft grills shall be inspected at the galvanizer-s plant prior to shipment.
j. The Contractor shall be furnished certification representing each galvanized shaft grills have been either tested or inspected as directed by the specifications and requirements have been met.
k. All damaged galvanized section shall be painted with cold zinc galvanizing paint.
Closing Date : 2019-07-08

Documents

Tender Notice
Login to view

Philippines Public Procurement Intelligence

Frequently asked questions

The bid deadline for Regalvanize Power Intake Closure Gate Shaft Grills at Elevation 200.25 MASL was 08 Jul 2019. Bidding is closed.

This tender has been issued by NATIONAL IRRIGATION ADMINISTRATION - MARIIS, DRD in Philippines.

The tender value is not disclosed; please refer to the tender document. EMD / bid security details are provided in the tender document.

This tender is Self Financed

The tender notice and related documents are listed in the Documents section above. Select a document to view or download it. Please log in or register to access the documents. If you cannot find additional documents in the Documents section, please log in to your account and Send Document Request from your account section.

The TendersOnTime reference is 34313105. The purchaser document reference is PURCHASE REQUEST NO. 218 - 2019.

Browse other tenders from Philippines or search by relevant keywords and CPV classification.