Summary: Philips Healthcare Large Bore, Dual Energy Computed Tomography (Ct) Simulator For Radiation Therapy Patient Image Acquisition
Deadline: 25 Jul 2019
Posting Date: 16 Jul 2019
Other Information
Notice Type: Tender
TOT Ref.No.: 34713197
Document Ref. No.: 75N91019Q00075
Competition: ICB
Financier: Self Financed
Purchaser Ownership: -
Tender Value: Refer Document
CPV Classification
33115000 - Tomography devices
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_details
Login to see detailsTender Details
National cancer institute (nci), center for cancer research (ccr), radiation oncology branch plans to procure, on a sole source basis, a philips healthcare large bore, dual energy computed tomography (ct) simulator from philips healthcare, 22100 bothell everett highway, bothell, wa 98401.
This acquisition will be processed under far part 12 - acquisition for commercial items and will be made pursuant to the authority in far 13.106-1 (b)(1)(i) using simplified acquisition procedures for commercial acquisitions. The north american industry classification system code is 334516 and the business size standard is 1, 000 employees.
The national cancer institute seeks to procure a philips healthcare large bore, dual energy computed tomography (ct) simulator for radiation therapy patient image acquisition as a replacement for and existing but obsolete unit; philips brilliance big bore.
The radiation oncology branch of the center for cancer research (ccr) treats cancer patients with radiation from linear accelerators according to approved clinical protocols or as standard of care. As an essential part of the treatment process, ct image sets must be acquired with the patient in the treatment position. This requires a ct simulator with a large (85cm) bore. The radiation oncology branch has such a device, but it is technologically obsolete. This requirement is intended to replace the obsolete unit with one that has state-of-the-art capabilities; especially for the emerging field of molecular markers, which necessitates image acquisition at two distinct x-ray energies. The following products are required for this requirement:
• big bore rt platinum ct simulator to include:
o 85cm physical bore size, with 60cm true and 70cm extrapolated fields of view
o gantry tilt of -30 to +30
o choice of spiral (helical) with cone beam reconstruction or axial scanning.
O provision of dynamic focal spot to double data sampling density
o flat therapy patient couch which su...