Procurement Summary
Country: Canada
Summary: Miniature wind tunnel (kw405-160519/a)
Deadline: 07 Oct 2015
Posting Date: 21 Sep 2015
Other Information
Notice Type: Tender
TOT Ref.No.: 3757374
Document Ref. No.: PW-$$PV-950-68023
Competition: ICB
Financier: Self Financed
Purchaser Ownership: -
Tender Value: Refer Document
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_details
Login to see detailsTender Details
Trade agreement: nafta/ait/canada ftas with peru/colombia/panama
tendering procedures: generally only one firm has been invited
to bid
non-competitive procurement strategy: exclusive rights
comprehensive land claim agreement: no
vendor name and address:
aerolab llc
8291 patuxent range rd
jessup maryland
united states
20794
nature of requirements:
1. Advance contract award notice (acan)
an acan is a public notice indicating to the supplier community
that a department or agency intends to award a contract for
goods, services or construction to a pre-identified supplier,
thereby allowing other suppliers to signal their interest in
bidding, by submitting a statement of capabilities. If no
supplier submits a statement of capabilities that meets the
requirements set out in the acan, on or before the closing date
stated in the acan, the contracting officer may then proceed
with the award to the pre-identified supplier.
2. Definition of the requirement
environment canada has a requirement for the supply,
installation and training of 1 customized mini wind tunnel (mwt)
to study the evaporation of liquid substances including crude
and fuel oils under various wind speeds and temperatures for
delivery to ottawa, ontario.
3. Criteria for assessment of the statement of capabilities
any interested supplier must demonstrate by way of a statement
of capabilities that its equipment meets the following
requirements:
the mwt is to be operated in a small lab equipped with a fume
hood. The outlet of the mwt (exhaust) will be connected/vented
to the fume hood. Specifically, the mwt must have the
following characteristics and be able to accommodate the
following ranges of the variables noted below:
type
open circuit to let the evaporative part evacuate to outside and
does not contaminate subsequent evaporation of the liquid.
Length
the maximum length of the mwt must not exceed 2.3 m.
Size of the test chamber (length x width x height)
two test chambers with related accessories for installation on
the mwt are required. The first one must be10 inch x 6 inch x 4
inch and the second must be 10 inch x 6 inch x 6 inch with
related accessories for installation on the mwt.
Wind speed
the mwt must be designed to operate continuously with constant
and uniform wind speed varying from 0 to ~10-15 m/s
flow uniformity and straightening
the mwt must be equipped with honeycomb-type screen or better to
ensure flow uniformity and straightening in the test section.
Turbulence control
the mwt must be equipped with the proper screening to reduce air
turbulence in the test section when running experiments at high
wind speeds.
Operational temperature range and control
the operational temperature range must be 0 to +35 oc or wider.
The mwt must include an integrated cooling/heating system to
control air temperature in the test chamber. Split systems are
not accepted.
Load cell
the mwt must be equipped w
Documents