Tender notice from Poland, published on 03 Oct 2015.
Executive Summary
The UrzAe has issued a Tender notice for the procurement of a Medical equipments in the Poland. This Tender notice was published on 03 Oct 2015 and is scheduled to close on 10 Nov 2015, with an estimated Tender value of Refer Document.
Interested bidders can access detailed Tender information, eligibility criteria, and complete bidding documents by referencing TOT Ref No. 3893635, while the tender notice number is 347272-2015 and Register on the platform.
Ogolne.1 requirements. The contract is for the supply columns anesthetic, columns surgical instruments and columns increased oversight on the need to expand Municipal Hospital in Piekary Slaskie and support and technical assistance during the installation and connection to the installation, and training employees User (PCM Sp. Z oo) with the scope of their Operating gksploatacji.2. At the moment the building, for which they were ... delivered a column anesthesia, surgical columns and columns wzmoĹĽonego supervision is carried out by the General Contractor ™ (DOMBUD SA Katowice), scheduled to end "connection of all robot-to-day" 31/01/2016 R3. The planned installation of these columns anesthesia, surgical columnsi?1/2and columns of increased oversight by the General Contractor, according to the schedule the robot to be held by the end of December 2015. The time of assembly columns can be changed subject to rescheduling the robot carried out by the General Wykonawcę.4. The Employer requires the supplier columns anesthesia, surgical columns and columns increased oversightdelivery in stages, taking account of the works by the General Contractor, without disrupting the schedule of the investment. Etapowość should provide gradual supply of the columns so that their assembly was possible until 31.12.2015 R.5. Necessary supplies (if provided mount technology) should be performed already in the rough in front of Regustart of robot decorating (assembly elements dirty), and the supply of components on a "purely" in a way which does not undermine the other work of the General Wykonawcy.6. Supplier of columns agree a detailed timetable for delivery of the Employer (Municipality of Piekary Slaskie), you and General Contractor works, without disturbing the work of the new building BN.7. Delivery apply to the following types of columns: Item. Type columns Number kompletow1 Column Column surgical anesthetic 42 43 108. Column increased oversight Supplier of columns is owed select and customize the columns to the premises of the new building BN applicable laws and standards, in particular those relating to inpatient compliance with its sThane faktycznym.9. The duty of the supplier of the object of the contract as part of the bid price is the delivery and support and technical assistance during installation columns anesthesia, surgical columns and columns increased oversight equipped in accordance with the provisions in these Terms of Reference or under applicable laws and standards and technical termsPieces for hospitals and equipment medycznych.10. Piping and wiring inside the arms of columns with the necessary technology inventory is a supplier and is located in the asking price. Along with columns at the offer price provider will also provide mounting hardware and grilles sufitowe.11. Created as part of the bid price will conduct training for employees ini?1/2operation and exploitation of the columns, as well as provide all certifications, approvals, reports, statements and instructions on paper and elektronicznej.12. Employer requires a minimum guarantee period of 60 months: a complex pisemnie.13. The Supplier shall be agreed before the columns of visualization and colors with the Employer and Użytkownikiem.14. Columns must be durable, functional and aesthetically wykonane.15. Columns must comply with all requirements of applicable laws and standards, in particular the technical, sanitary, health and safety, fire protection. : In the range of medical and medycznych.16 products. The exact arrangement of all slots on the columns prior to their implementation should be agreed with THE USEpretty and Zamawiającym.Wymagania share special columns anesthetic: 1) Column new, unused, not-recycled, manufactured not earlier than 2015.2) Column equipped with friction brakes and air in all przegubach.3) knobs for positioning columns to control a whole and the individual elements of columns feature the control buttons lrownoważny.4 the previous system) device is designed to be installed in the operating room, the ceiling of a two-part articulated arm, przegubowym.5) device easy to clean, resistant to cleaning and disinfecting products also alcohol-based, smooth surfaces without protruding elements, shapes rounded with no sharp edges and edges without visible bolts onb, nuts etc.6) head equipped with separate ducts for the installation of gas and electricity, 7) Expandable column of additional electrical outlets and gas, extra shelves and brackets for attaching hardware, 8) A set of electrical and gas connections. Gas pipes from the plant hospital attached in accordance with applicable laws and standards, 9) Occupationieszenie columns: slab together with a gas-electric connections and ceiling grille. Medical gas pipeline on fast attached to the wiring szpitalnej10) distribution arms within minutes of total 2000 mm.11) Load column understood as the weight of medical equipment that can be set up on a column of at least 150 kg.12) Angle of rotation ini?1/2All joints minute 330.13) Distribution of gas and electric sockets possible on all the walls, as expected Użytkownika.14) medical gas outlet points AGA: 2 x oxygen, 2 x vacuum, 2 x compressed air, 1 x nitrous oxide, 1 x extraction anestetycznych.15 gases) Minimum positioning of medical gas outlet 70 cm from podłogi.16)Equipped with electrical outlets at least 12 electrical outlets 230V / 50 Hz with earth pin, splash-proof (clamshell), a minimum 12 holes equipotent, at least 3 slot telekomunikacyjne.17) Number of circuits electric: At least 4 1 Circuit awaryjny.18) Column connected to existing gas installation and elektrycznej.19) The availability of spare parts fori?1/2at least 10 years from the date of installation sprzętu.20) offered the device must be certified CE.21) Dimensions column adapted to equipment in who is to be wyposażona22) Minimum equipment: 1 x shelf, 1 x basket on excess cables and wires, 2 x hardware bus attached to the head, 1 x vertical shaft infusion pumps with a minimum length of 1000 mm on their owni?1/2a double arm: a range of a minimum of 1000 mm, finished hanger infusion in the form of strips with a minimum of 4 hooks in a row on one side of the strip, hooks for hanging various kinds of accessories for the basket or on a strip sprzętowej.23) The head of the column equipped with electrical wires fastening system eg. zatrzaski.24) entry in the register devices medycznych.25) colors to determine the UżytkownikiemWymagania SPECIFIC surgical columns: 1) Column new, unused, not-recycled, manufactured not earlier than 2015.2) Column equipped with friction brakes and air in all przegubach.3) knobs for positioning columns to control the whole and individual elements Col.Umnye equipped with control keys or rownoważny.4 system) device is designed to be installed in the operating room, the ceiling of a two-part articulated arm, przegubowym.5) device easy to clean, resistant to cleaning and disinfecting products also alcohol-based, smooth surfaces excluding the projecting parts, rounded shapes with no sharpch and edges without visible screws, nuts etc.6) head equipped with separate channels for the gas installation and elektrycznej.7) Expandable column of additional electrical outlets and gas, extra shelves and brackets for sprzętu.8) electro Connection Kit gas. Gas pipes connected with the hospital system in accordance with current-limiting laws and normami.9) Suspension columns: slab together with a gas-electric connections and ceiling grille. Medical gas pipeline on fast attached to the wiring szpitalnej.10) distribution arms with a total range of at least 1500 mm.11) Load column understood as the weight of medical equipment that can be PosadowiceColumn least 150 kg.12) Angle of rotation in all joints minute 330.13) Distribution of gas and electric sockets possible on all the walls, as expected Użytkownika.14) medical gas outlet points AGA: 2 x vacuum 2 x CO2 2 x Compressed powietrze.15) Minimum positioning of medical gas outlet 70 cm from podłogi.16) Equipmenti?1/2in electrical sockets at least 10 electrical outlets 230V / 50 Hz with earth pin, splash-proof (clamshell), a minimum of 10 seats equipotent, a minimum of 3 slot telekomunikacyjne.17) Number of circuits electric: At least 4 1 Circuit awaryjny.18) Column plugged into existing installations gas and elektrycznej.19) Minimum: 4 shelves with dimensions not lessenh: width 45 cm / -10%, a depth of 45 cm / -10%; equipped with side rails on the right and the left, with a capacity of at least 30 kg. The ability to modify any user height shelves, 1 x basket on excess cables and wires, 2 x rail hardware attached to the head, 1 x vertical shaft infusion pumps with a minimum length of 1000 mm on their own podwojnym shoulder: a range of a minimum of 1000 mm, finished hanger infusion in the form of a strip of at least 4 hooks in a row on one side of the strip, hooks for hanging various kinds of accessories for the basket or on a strip sprzętowej.20) single drawer under the shelf for excess wires electric grip on the bottle Argonu.21) Availability of zamiennych for at least 10 years from the date of installation sprzętu.22) offered the device must be certified CE23) Dimensions column adapted to equipment in who is to be wyposażona.24) The head of the column equipped with electrical wires fastening system, for example. zatrzaski.25) Entry on the register medycznych.26) colors to determine the UżytkownikiemWymagania particuticular the columns increased oversight: 1) Column new, unused, not-recycled, manufactured not earlier than 2015.2) Column equipped with friction brakes and air in all przegubach.3) knobs for positioning columns to control a whole and the individual elements of a column equipped with control buttons or the system rownoważny.4) UrLust for installation in the hall increased oversight, ceiling, with a two-part articulated arm, przegubowym.5) device easy to clean, resistant to cleaning and disinfecting products also alcohol-based, smooth surfaces without protruding elements, rounded shapes with no sharp edges and Eaves without visible screws, nuts etc.6)Head equipped with separate channels for the gas installation and elektrycznej.7) Expandable column of additional electrical outlets and gas, extra shelves and brackets for sprzętu.8) set of electro-gas connections. Gas pipes connected with the hospital system in accordance with the przepisami9) Suspension columns: slab sensitivezz plate gas and electrical connections and ceiling grille. Medical gas pipeline on fast attached to the wiring szpitalnej.10) distribution arms with a total range of at least 1, 400 mm.11) Load column understood as the weight of medical equipment that can be set up on a column of at least 150 kg.12) Angle of rotation in all joints 330 min.13) Distribution of gas and electric sockets possible on all the walls, as expected Użytkownika.14) medical gas outlet points AGA: 2 x oxygen, 2 x vacuum, 2 x compressed powietrze.15) Minimum positioning of medical gas sockets: 70 cm podłogi.16) Devices in the electrical sockets at least 12 electrical outlets 230V / 50 Hz with pini?1/2ground, splash-proof (clamshell), a minimum of 8 slots equipotent, a minimum of 3 slot telekomunikacyjne.17) Number of circuits electric: At least 4 1 Circuit awaryjny.18) column connected to the existing gas system and elektrycznej.19) Minimum 3 shelves not smaller than: 65 cm / -10%, a depth of 45 cm / -10% equipped with railsi?1/2the side on the right and left sides with a capacity of at least 30 kg. The ability to modify at will the height of the shelves by the User, 3 drawers with a height of 10-15 cm and a minimum capacity of 3 kg mounted beneath the shelves, 2 x vertical shaft infusion pumps with a minimum length of 1000 mm to own a double arm: a range of a minimum of 1000 mm, complete hanger Infusion fluidsPieces in the form of a strip of at least 4 hooks in a row on one side of the strip, hooks for hanging various kinds of accessories for the basket or terminal hardware, 2 x rail hardware attached to the head, 2 x basket on excess cables and wires, 20) The availability of spare parts for at least 10 years from the date of installation sprzętu.21) offered the device must psettle certificate CE22) Dimensions column adapted to equipment in who is to be wyposażona.23) The head of the column equipped with electrical wires fastening system, for example. zatrzaski.24) Entry on the register medycznych.25) colors to determine the UżytkownikiemRozwiązania equivalent: indicated in Terms of Reference and technical documents trademarks, patents and place mineraloilcooling are justified by the nature subject of the contract and are intended to identify only the quality and parameters subject of the order due to the absence of other sufficiently precise terms, which would allow describe the subject orders in this area for a clear and comprehensive way. Accordingly, the Contractor may submit bids equivalent to the Object ofHere orders given in the Terms of Reference: according to Art. 30 paragraph. 4 and 5 Ustawy.W therefore: 1. Employer allows the use of materials and equipment equivalent: ie. About technical parameters and quality not worse than those specified in the Terms of Reference: for materials and equipment, whose origin is determined by the Purchaser in the tender documents and the documents technicznych name producenta.2. In accordance with Art. 30 paragraph. 5 of the Act Contractor, which refers to equivalent solutions is obliged to prove that he offered supplies, services, works meet the requirements set by the Employer. Equivalence in terms of technical parameters, performance and operational aims in particular to guarantee replementation ™ robot in accordance with the technical documentation ... ... and provide ‡ obtaining technical parameters not worse than zaĹ, oĹĽonych out herein. Description: Medical equipments Authority Type: Regional or local authority
Contact Nature: Supplies
Procedure: Open procedure
Document: Contract notice
Regulation: European Union
Award criteria: The most economic tender
CPV code: 33100000
CPV Description: Medical equipments.   Internet address (URL): www.bip.piekary.pl
The bid deadline for Medical equipments was 10 Nov 2015. Bidding is closed.
This tender has been issued by UrzAe in Poland.
The tender value is not disclosed; please refer to the tender document. EMD / bid security details are provided in the tender document.
This tender is Self Financed
The tender is classified under the following CPV code(s): 33100000 - Medical equipments.
The tender notice and related documents are listed in the Documents section above. Select a document to view or download it. Please log in or register to access the documents. If you cannot find additional documents in the Documents section, please log in to your account and Send Document Request from your account section.
The TendersOnTime reference is 3893635. The purchaser document reference is 347272-2015.