LPI No. 02/2015 - "Acquisition of Critical Care Tender - 4020882
Tender notice from Argentina, published on 15 Oct 2015.
Executive Summary
The PROGRAMA DE NACIONES UNIDAS PARA EL DESARROLLO -PNUD has issued a Tender notice for the procurement of a LPI No. 02/2015 - "Acquisition of Critical Care Medical Equipment" in the Argentina. This Tender notice was published on 15 Oct 2015 and is scheduled to close on 05 Nov 2015, with an estimated Tender value of Refer Document.
Interested bidders can access detailed Tender information, eligibility criteria, and complete bidding documents by referencing TOT Ref No. 4020882, while the tender notice number is 25773, 002/2015 and Register on the platform.
Key facts
Summary
LPI No. 02/2015 - "Acquisition of Critical Care Medical Equipment"
Bids for Acquisition of Critical Care Medical Equipment for Strengthening the Management of the Ministry of Health of the Province of Buenos Aires Project
Real object of the contract: The purpose of this tender is the procurement of goods with detailed technical specifications.
Description:
Surgery Mesa High Complexity
Ecografo operating room
Double Scialitica
Respirators High Complexity
Ecografo Low Complexity
Ecografo of medium complexity
Ecografo High Complexity
Ultrasound laptop
Capnography monitors
Multiparameter monitor
Monitor UTI
Desfibirilador to Cart
Transport incuvadora
Servocuna
Technical specifications LOT 1:
Line 1: Surgery Mesa High Complexity
Mobile operating table electrohydraulic drive for the functions of height, lateral tilt and Trendelenburg / Reverse Trendelenburg.
Construction features:
Solid base construction with double disc rollers for easy movement and maneuvering. It must be designed for patients weighing up to 360 Kg.
Lining of fiber reinforced laminated glass, resistant to impact, breakage and disinfectants, with additional scratch-resistant coating.
Board frame and completely covering the column in chrome-nickel.
The system must have 4 wheels of large proportions, together with brake pedal general surgical table.
Board divided into 6 sections: head plate, extension plate, back plate, seat plate and to leg plates.
The board should be free, without cross shadows on X-ray images
Joints protected to ensure secure positioning.
Remote controls: Control pendant light with cable and panel table column to control it.
SFC cushion (lower layer of synthetic material 20 mm EPDM - ethylene propylene diene monomer - glued a layer of viscoelastic foam 60 mm), with velcro attachable to the carrier plates, and conductive radiolucent. The combination of viscoelastic foam and EPDM ensures optimum pressure distribution avoiding pressure sores, as well as contributing to the patient's physiological stability.
While the measures of it, the main unit should be more than 1000 mm and accessories must reach a length of over 1900 mm. The width of the table without rails must be 540 mm and 590 mm thereof. Heights to be achieved (without considering the mattresses): min 600 mm - 950 mm max.
The table must have the following fully electric movements (controllable from the remote control) Trendelenburg, reverse Trendelenburg, tilting left and right, up and down the table as a whole, Flex, Reflex, raising and lowering of the backrest and positioning zero. You will also have the possibility of being used both as a reverse direction in order to use the electric movement of the back with stirrups.
On the other hand the head plate should allow free movement (up-down) by releasing the brake. As the chaps must permit manual opening.
Electrical Characteristics:
It must have rechargeable battery with autonomy for a week's use in the operating room.
Accessories include:
1 Plate head
1 Plate elongation
1 Leg plates, pair
1 backlit button control cable
2 Armrest
1 Strap clamp
1 Arch narcosis
3 radial Fasteners
2 chaps, Goepel Row 2: Ultrasound for Operating Room
The system should be mobile, battery for easy portability and equipped with a simple user interface that can be used for non-traditional ultrasound users.
The control panel must have an area of ​​tempered glass, sealed and easy to clean.
System controls should change dynamically, displaying only the keys and automated functions that support the review being done to reduce unnecessary interaction with the system. The system must be new, unused, with the latest technology. With complete applications for Critical Care and Obstetrics / Gynecology, including software and hardware for:
Abdominal
Trauma
Adult Eco
Shallow
Access
Peripheral vascular,
Pulmonary
PW
CW
Physiological.
Pelvic Pelvic exam which includes analysis of gynecology and obstetrics. It includes quick reports, fully configurable reports and biopsy capabilities. You can also incorporate future the following applications:
Pain Medicine and Regional Anesthesia
Nerves
Musculoskeletal
Ocular The scanner must have at least the following characteristics:
Transducers:
The ultrasound system should provide a full complement of transducers, designed and optimized for a wide variety of tests and automatic parameter optimization of each transducer for exam type by acquisition software specific images of tissues. It should include the following transducers:
One (1) linear array transducer broadband frequency range from 12 to 4 MHz
For acquisition applications vascular imaging, vascular access, and superficial.
It should have extended operating frequency range of 12-4 MHz
It must have at least linear array with 128 elements
The length of the array must be at least 38 mm.
One (1) curved transducer array with a frequency range of 6 to 2 MHz:
For abdominal and pelvic general purpose applications
It must have extended operating frequency range of 6 to 2 MHz
It must have curve group with at least 128 items
The group must have a radius of curvature of at least 50 mm Control Panel
The control panel and user interface shall:
Graphical user interface easy to learn.
Mode by which presents only those controls that are used most frequently with the press of a button.
Surface hardened, sealed and easy to clean glass without keys or protruding buttons. General characteristics
The team must have:
High resolution color monitor, played in 17 of the ". It must be mounted in a fully articulated arm angle and rotation for easy orientation.
At least 5 USB flash drives in the system
Internal DVD RW drive
A function that automatically identifies the type of tissue and continuously adapt the gain of the image while carrying out exploration ·
A less than 60 kg.
A hard disk with a storage capacity exceeding 300 GB
Internal battery with a duration of not less than 2 hours
Standby mode that allows the user to save battery power when not being used
Control for automatic optimization of 2D / Doppler / color Doppler iScan or similar.
Control for continuous and automatic optimization in 2D or type AutoSCAN like.
Hotkeys
Selection of transducers and acquisition control according to the tissue specific images being watched.
DICOM Networking
System architecture:
The system must have:
Forming the beam must be art, compact, fully digital and broadband capacity for pulse shaping.
A / D conversion of high resolution, dynamic range of the system full time at least 165 dB
At least 19, 800 digitally processed channels
The equipment must be compatible with the technology of crystals of pure wave.
Acquisition of harmonic imaging array including multiple processing inversion pulse
Acquisition of composite images of several ultrasonic beams in real time to prevent acoustic shadows, like type SonoCTo
Software adaptive image processing for noise reduction and artifacts to enhance the visibility of tejidotipo XRES or the like
Advanced control for image acquisition allows the flexibility to light the advanced controls for the acquisition of exams. Imaging modes
You shall have the following imaging modes:
2D
Mode M (M mode in real time)
Anatomical M-Mode
Color mode M
Color imaging by PowerAngio (CPA).
For comparison of color.
Dual mode
It must also have the following functions:
Compare Live
Acquisition of Tissue Harmonic Imaging (THI)
Zoom to write HD
Acquisition of trapezoidal images
Harmonic Imaging acquisition pulses Investment
Native data assets (allows manipulation of the raw data image)
Pulse wave Doppler (PW)
Doppler continuous wave (CW) Also, you should be able to incorporate future:
Acquiring tissue Doppler imaging by pulse waves / Color
Needle visualization to help the user to guide the needle to the target anatomy.
Sectoral grouping transducer with a frequency range of 4 to 2MHz for cardiac applications
Curved transducer array with an extended operating frequency range of 9-4 MHz and a field of view of at least 150 degrees to endovaginal applications.
Transesophageal probe with a frequency range from 7 to 2 MHz.Deberá pure crystals possess wave matrix array of at least 2500 elements. Row 3: Double Lamps scialytic
ScialÃtica 2 domes lamp LED technology with anchor system.
Main dome intensity of at least 130, 000 lux high intensity dome least 120, 000 lux.
If need more light head lamp must have the possibility of increasing the intensity at least 150, 000 lux.
Life of greater LEDS a50.000hs.
Both domes must be precableadasde HD video in the future to add a camera.
The lamp must have be able to change in color temperature adjustable three levels: 3900 K, 4500 K and 5100 K. The lamp must have white LEDs that provide stability over time without colored shadows. The change of color temperature to be through a system of cold filters.
It should have a control panel that has a touch for total handling the light display that includes at least on and off, intensity, management field diameter variation of color temperature, storage possibility of specific settings for each type of surgery and in the case of adding in the future camera, the handling of it.
The lamp shall ensure constant lighting a depth of at least 1 meter, sinnecesidad adjustment, which does not alter the viewing conditions in multiple surgical procedures.
The lamp must have a system that ensures that the light intensity remains constant during surgery, even in prolonged surgeries. This should stabilize the lighting system
and avoid variations in light intensity, offsetting the loss inherent in LED lighting technology.
It should be possible to vary the diameter of the light field electronically.
The lamp must have a green light environment that favors the contrast on the screen during mininamente invasive surgeries.
The lamp must have lamisma dome in a control panel for light intensity, the diameter of the field, turning on ambient light and the zoom control in the case of having a camera installed.
You must meet the following characteristics: Diameter of the light field d10 (cm): 20 -25
Diameter of the light field d50 (cm): 11 -14
Diameter ratio d50 / d10: ≥ 0.55
Light volume depth L1 + L2 20% (cm): 110
Light volume depth L1 + L2 60% (cm): 50
Color rendering index (%) (Ra): 95
Lighting energy (W / m) 500
energy irradiation (mw / m².lx): 3.5 the lamp shall comply with the following standards:
iec60601-1
iec60601-2-41
en60601-1-2
[disclaimer: the below text is machine translated. for accurate information kindly refer the above text in original language.]
The bid deadline for LPI No. 02/2015 - "Acquisition of Critical Care Medical Equipment" was 05 Nov 2015. Bidding is closed.
This tender has been issued by PROGRAMA DE NACIONES UNIDAS PARA EL DESARROLLO -PNUD in Argentina.
The tender value is not disclosed; please refer to the tender document. EMD / bid security details are provided in the tender document.
This tender is financed by United Nations Secretariat.
The tender is classified under the following CPV code(s): 33100000 - Medical equipments.
The tender notice and related documents are listed in the Documents section above. Select a document to view or download it. Please log in or register to access the documents. If you cannot find additional documents in the Documents section, please log in to your account and Send Document Request from your account section.