Expired Tender Canada ICB TOT Ref. 125812851

Helium Gas Cryogenic Cooling System Tender in Canada - 125812851

Tender notice from Canada, published on 06 Sep 2025.

Executive Summary

The UNIVERSITY OF OTTAWA has issued a Tender notice for the procurement of a Helium Gas Cryogenic Cooling System in the Canada. This Tender notice was published on 06 Sep 2025 and is scheduled to close on 10 Oct 2025, with an estimated Tender value of Refer Document. Interested bidders can access detailed Tender information, eligibility criteria, and complete bidding documents by referencing TOT Ref No. 125812851, while the tender notice number is 43981-4A-RFP(R2) and Register on the platform.

Key facts

Summary
Helium Gas Cryogenic Cooling System
TOT Ref. No.
125812851
Document Ref. No.
43981-4A-RFP(R2)
Country
Canada
Notice type
Tender
Competition
ICB
Publication date
06 Sep 2025
Bid deadline
10 Oct 2025
EMD
Refer Document
Tender value
Refer Document
Purchaser ownership
Public
Financier
Self Financed

Purchaser details

Purchaser contact is for registered users

Login to see details

Tender details

The University is soliciting prospective proponents to submit proposals for a Helium Gas Cryogenic Cooling System.The Helium Gas Cryogenic Cooling System will be used to cool a laser amplifier. The laser crystals, which need to be cooled to ~90 K, are mounted on cold fingers located in a vacuum chamber, which itself needs to operate at ~ 90 K. The low-temperature helium gas from the proposed Helium Gas Cryogenic Cooling System runs through the cold fingers. The thermal load generated by the laser crystals is 600 W. The helium transfer line should not cause large vibration to the cold finger. The stability of the temperature should be less than 10 K. The coolers must operate without using liquid nitrogen. The instrument must operate for 24 consecutive hours; 7 days per week (24/7), outside of planned shutdowns for annual maintenance.In the cooling system, helium gas is cooled at the cold head to ~90 K and transferred into the helium cycling pump for pressurization. The low temperature helium gas will then be outputted onto the laser crystals for one-way cooling. The returned helium is then cooled down again for cycling.The cold finger on which the crystals are mounted are supplied by the University. The pressure drop is 15 to 30 kPa. The University will also be supplying the cryostat vacuum chamber. The interfaces for the helium transfer line to the cold heads is UHV Flange. Mandatory Requirements:1. Helium Gas Cryogenic Cooling System 1.1 Proposed solution must be composed of...
Solicitation Type : RFP - Request for Proposal (Formal)

Reference Number : 0000302156

Location : Canada, Ontario, Ottawa

Delivery Point : University of Ottawa

Purchase Type : One Time Only- Delivery Date:2026/03/31

Description : The University is soliciting prospective proponents to submit proposals for a Helium Gas Cryogenic Cooling System.The Helium Gas Cryogenic Cooling System will be used to cool a laser amplifier. The laser crystals, which need to be cooled to ~90 K, are mounted on cold fingers located in a vacuum chamber, which itself needs to operate at ~ 90 K. The low-temperature helium gas from the proposed Helium Gas Cryogenic Cooling System runs through the cold fingers. The thermal load generated by the laser crystals is 600 W. The helium transfer line should not cause large vibration to the cold finger. The stability of the temperature should be less than 10 K. The coolers must operate without using liquid nitrogen. The instrument must operate for 24 consecutive hours; 7 days per week (24/7), outside of planned shutdowns for annual maintenance.In the cooling system, helium gas is cooled at the cold head to ~90 K and transferred into the helium cycling pump for pressurization. The low temperature helium gas will then be outputted onto the laser crystals for one-way cooling. The returned helium is then cooled down again for cycling.The cold finger on which the crystals are mounted are supplied by the University. The pressure drop is 15 to 30 ...

Documents

Tender Notice
Login to view

Canada Public Procurement Intelligence

Frequently asked questions

The bid deadline for Helium Gas Cryogenic Cooling System was 10 Oct 2025. Bidding is closed.

This tender has been issued by UNIVERSITY OF OTTAWA in Canada.

The tender value is not disclosed; please refer to the tender document. EMD / bid security details are provided in the tender document.

This tender is Self Financed

The tender notice and related documents are listed in the Documents section above. Select a document to view or download it. Please log in or register to access the documents. If you cannot find additional documents in the Documents section, please log in to your account and Send Document Request from your account section.

The TendersOnTime reference is 125812851. The purchaser document reference is 43981-4A-RFP(R2).

Browse other tenders from Canada or search by relevant keywords and CPV classification.