Expired Tender Canada ICB TOT Ref. 120355644

Helium Gas Cryogenic Cooling System Tender in Canada - 120355644

Tender notice from Canada, published on 05 Jun 2025.

Executive Summary

The UNIVERSITY OF OTTAWA has issued a Tender notice for the procurement of a Helium Gas Cryogenic Cooling System in the Canada. This Tender notice was published on 05 Jun 2025 and is scheduled to close on 02 Jul 2025, with an estimated Tender value of Refer Document. Interested bidders can access detailed Tender information, eligibility criteria, and complete bidding documents by referencing TOT Ref No. 120355644, while the tender notice number is 43981-4A-RFP and Register on the platform.

Key facts

Summary
Helium Gas Cryogenic Cooling System
TOT Ref. No.
120355644
Document Ref. No.
43981-4A-RFP
Country
Canada
Notice type
Tender
Competition
ICB
Publication date
05 Jun 2025
Bid deadline
02 Jul 2025
EMD
Refer Document
Tender value
Refer Document
Purchaser ownership
Public
Financier
Self Financed

Purchaser details

Purchaser contact is for registered users

Login to see details

Tender details

The University is soliciting prospective proponents to submit proposals for a Helium Gas Cryogenic Cooling System.The Cryogenic Cooling System will be used to cool a laser amplifier. The laser crystals, which need to be cooled to
70 K, are mounted on cold fingers located in a vacuum chamber, whichitself needs to operate at
70 K. The low-temperature helium gas from the proposed Cryogenic Cooling System runs through the cold fingers. The thermal load generated by the laser crystals is 800 W, which can be supported by a solution consisting of either one or two helium cryogenic coolers. Thehelium transfer line should not cause large vibration to the cold finger. The stability of the temperature should be less than 10 K. The coolers should operate without using liquid nitrogen. The instrument must operate for 24 consecutive hours; 7 days per week (24/7), outside of planned shutdowns forannual maintenance.In the cooling system, helium gas is cooled at the cold head to
70 K and transferred into the helium cycling pump for pressurization. The low temperature helium gas will then be outputted onto the laser crystals for one-way cooling. The returned helium is finally then cooled downagain for cycling.Mandatory Requirements:1.Helium Gas Cryogenic Cooling System 1.1 Proposed solution must be composed of one of the following: One (1) unit with a maximum cooling power using circulated helium gas of 800 W or higher at 70 K; or Two (2) units, each with a maximum cooling power using...
Solicitation Type : RFP - Request for Proposal (Formal)

Reference Number : 0000295208

Location : Canada, Ontario, Ottawa

Delivery Point : University of Ottawa

Purchase Type : One Time Only- Delivery Date:2026/03/31

Description : The University is soliciting prospective proponents to submit proposalsfor a Helium Gas Cryogenic Cooling System.The Cryogenic Cooling System will be used to cool a laser amplifier. The laser crystals, which need to be cooled to

70 K, are mounted on cold fingers located in a vacuum chamber, which itself needs to operate at

70 K. The low-temperature helium gas fromthe proposed Cryogenic Cooling System runs through the cold fingers. The thermal load generated by the laser crystals is 800 W, which can be supported by a solution consisting of either one or two helium cryogenic coolers. The helium transfer line should not cause large vibration to the cold finger.The stability of the temperature should be less than 10 K. The coolers should operate without using liquid nitrogen. The instrument must operate for 24 consecutive hours; 7 days per week (24/7), outside of planned shutdowns for annual maintenance.In the cooling system, helium gas is cooled at the coldhead to

70 K and transferred into the helium cycling pump for pressurization. The low temperature helium gas will then be outputted onto the laser crystals for one-way cooling. The returned helium is finally then cooled down again for cycling.MandatoryRequirements:1.Heli...

Documents

Tender Notice
Login to view

Canada Public Procurement Intelligence

Frequently asked questions

The bid deadline for Helium Gas Cryogenic Cooling System was 02 Jul 2025. Bidding is closed.

This tender has been issued by UNIVERSITY OF OTTAWA in Canada.

The tender value is not disclosed; please refer to the tender document. EMD / bid security details are provided in the tender document.

This tender is Self Financed

The tender notice and related documents are listed in the Documents section above. Select a document to view or download it. Please log in or register to access the documents. If you cannot find additional documents in the Documents section, please log in to your account and Send Document Request from your account section.

The TendersOnTime reference is 120355644. The purchaser document reference is 43981-4A-RFP.

Browse other tenders from Canada or search by relevant keywords and CPV classification.