The united states postal service (usps) plans to issue a firm fixed price contract for the hvac systems replacements and upgrades at the harrisburg p&dc located at 1425 crooked hill rd in harrisburg pa 17107-9371. All work will be done in accordance with usps approved specifications and drawings. The construction performance time for this project is 365 calendar days from notice to proceed.
Proposal: contractors will be required to submit a qualification statement/package (attachment 24), a management/technical plan (attachment 12) and their price proposal.
To be considered, a company must meet the following minimum requirements as shown in the qualification statement/package (attachment 24): background, eligibility, certification and affirmation, bonding information, financial capability, safety, and comparable experience.
Pre-qualified contractors will be placed on a list for inclusion in future solicitations in this area with similar scopes of work. There is no guarantee that a specific number of solicitations will be issued to these pre-qualified contractors.
The postal service is more concerned with making an award at the lowest overall price than with obtaining superior technical or management features. However, the postal service may not necessarily make an award at the lowest price in order to achieve a small price savings if better value can be achieved with superior technical or management features. The benefits of a higher priced proposal may merit a higher price.
Scope of work:
a. The scope of work includes but is not limited to the following:
remove all existing pneumatic controls and digital control system.
Provide a complete ddc controls system to control all existing hvac equipment.
Remove existing pneumatic control valves and replace with new ddc control valves.
Remove existing pneumatic damper actuators and replace with new ddc actuators.
Provide web-based controls software to mimic existing control logic.
Provide all controls in compliance with current usps and eems standards.
Replace penthouse equipment as specified.
Install new rooftop equipment as specified.
Install new supplementary units as specified.
Provide hvac piping and ductwork as indicated.
Provide and install new gas line piping from the new meter to end use utilities as indicated.
Electrical demolition as indicated.
Provide new electrical panels, disconnect switches, feeders and branch circuit wiring for all new hvac equipment.
Provide new circuit breakers for existing switchboards and panels.
Provide new fuse buckets for existing motor control centers.
Remove and replace ceilings to allow above hvac work. (partial ceiling and complete room ceiling - see architectural drawings for extents per room)
construct new chases in public lobbies.
Remove, salvage, and reinstall lighting as required to allow above hvac work. Temporarily suspend and reinstall all other ceiling mounted utilities.
Erect, maintain, and dismantle scaffolding and complete plywood work floor in the public lobbies to allow work to be performed during business hours with minimal disruption.
Provide selective site demolition and utility trenching to existing gas main in crooked hill rd. Provide utility bedding for utility install of new gas line and meter. Re-establishment of site turf and grasses, asphalt roadways, concrete curbs, and sidewalks to existing conditions.
Coordinate commissioning process with third party commissioning agent.
Provide owner training as specified.
Solicitation: the solicitation package is attached to this posting. The solicitation package will be divided into six parts: 1) specifications, 2) drawings arch, 3) drawings elec, 4) drawings mech, 5) solicitation, and 6) return package
questions should be directed to: sharon russell,
[email protected]. Deadline for questions is noon on november 4, 2015.
There will be no public opening of offers. All proposal information received is confidential until award of a contract. Upon award, the name of the successful offeror and the amount of the contract will be released as public information. The names of the offerors and the amount of their offers will not be released as public information. This information is exempt from disclosure under the freedom of information act, exception 4.please consult the list of document viewers if you cannot open a file.
Drawings arch
type: other (draft rfps/rfis, responses to questions, etc..) label:
drawings arch
posted date: october 7, 2015 drawings_arch.pdf (12, 872.09 kb)
description: drawings architectural 10-06-15
drawings elec
type: other (draft rfps/rfis, responses to questions, etc..) label:
drawings elec
posted date: october 7, 2015 drawings_elec.pdf (9, 638.90 kb)
description: drawings elec 10-06-15
drawings mech
type: other (draft rfps/rfis, responses to questions, etc..) label:
drawings mech
posted date: october 7, 2015 drawings_mech.pdf (19, 199.99 kb)
description: drawings mech 10-06-15
return package
type: other (draft rfps/rfis, responses to questions, etc..) label:
return package
posted date: october 7, 2015 return_package.pdf (1, 240.31 kb)
description: return package 10-06-15
solicitation
type: other (draft rfps/rfis, responses to questions, etc..) label:
solicitation
posted date: october 7, 2015 solicitation.pdf (6, 859.95 kb)
description: solicitation 10-06-15
specifications
type: other (draft rfps/rfis, responses to questions, etc..) label:
specifications
posted date: october 7, 2015 specifications.pdf (3, 587.20 kb)
description: specifications 10-06-15
amendment 1
type: mod/amendment posted date: october 14, 2015 amendment_a01.pdf (967.16 kb)
description: amendment a01 pre-proposal information
rfi # 001
type: other (draft rfps/rfis, responses to questions, etc..) label:
rfi # 001
posted date: october 15, 2015 rfi___001.pdf (629.22 kb)
description: rfi # 001 10-15-15
pre-proposal minutes and sign in
type: other (draft rfps/rfis, responses to questions, etc..) label:
pre-proposal minutes and sign in
posted date: october 24, 2015 pre-proposal_minutes_and_sign_in.pdf (2, 064.17 kb)
description: pre-proposal meeting minutes and sign in sheet
rfi # 004
type: other (draft rfps/rfis, responses to questions, etc..) label:
rfi # 004
posted date: october 26, 2015 rfi_004.pdf (135.88 kb)
description: rfi # 004 10-26-2015
rfi #007
type: other (draft rfps/rfis, responses to questions, etc..) label:
rfi #007
posted date: october 26, 2015 rfi_007.pdf (7.86 kb)
description: rfi # 007 10-26-2015
1425 crooked hill rd
harrisburg, pennsylvania 17107
united states
primary point of contact.:
sharon j russell
[email protected]phone: (214) 819-7218
fax: (214) 819-8887 all files
drawings arch
oct 07, 2015
drawings_arch.pdfdrawings elec
oct 07, 2015
drawings_elec.pdfdrawings mech
oct 07, 2015
drawings_mech.pdfreturn package
oct 07, 2015
return_package.pdfsolicitation
oct 07, 2015
solicitation.pdfspecifications
oct 07, 2015
specifications.pdfamendment 1
oct 14, 2015
amendment_a01.pdfrfi # 001
oct 15, 2015
rfi___001.pdfpre-proposal minutes and sign in
oct 24, 2015
pre-proposal_minutes...download/view pre-proposal_minutes_and_sign_in.pdfrfi # 004
oct 26, 2015
rfi_004.pdfrfi #007
oct 26, 2015
rfi_007.pdfgeneral information
z -- maintenance, repair, and alteration of real property
naics code:
238 -- specialty trade contractors/238220 -- plumbing, heating, and air-conditioning contractors
238 -- specialty trade contractors/238220 -- plumbing, heating, and air-conditioning contractors
for help: federal service deskaccessibility
added: oct 07, 2015 12:43 am