Procurement Summary
Country: USA
Summary: Fire Alarm Sprinkler Installation Repair, and Maintenance / Testing at Va Illiana Health Care System, Danville, Il
Deadline: 29 May 2024
Posting Date: 22 May 2024
Other Information
Notice Type: Tender
TOT Ref.No.: 101547264
Document Ref. No.: 36C25224Q0518
Competition: ICB
Financier: Self Financed
Purchaser Ownership: Public
Tender Value: Refer Document
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_details
Login to see detailsTender Details
Description
Scope of work:The vendor shall provide all labor, material, supplies, equipment, management, and supervision to Repair, Install components, and Test Sprinkler systems in Bldg. s 14, 58, 102 and 104; at the VA Illiana Healthcare System 1900 East Main Street, Danville, Il 61832 Services to be provided: Bldg. 14 Replace and re-pipe the Inspectors test valve in Attic. Remove ball valve replace with new restricted orifice site glass and ball valve at chest level. This will be piped to center of drain with gunner nipple. Test system for leaks and full flow test verify floor drain handles flow. Bldg. 58 Replace Six Dry sidewall sprinkler heads that feed exterior rooms. Bldg. 58 Replace 35 Recalled Sprinkler heads in machinal room and service elevator dock. Bldg. 102 Replace 4 OS&Y (Zone 5) in hallway outside main mechanical room. Bldg. 104 replace 30 dry sprinkler heads in the coolers and freezers in the main kitchen and café. This will be using flex drop dry sprinkler heads. Must repipe as needed to keep all flex drops the same length. Drain sprinkler systems as needed to complete work. Fill and leak check sprinkler system each day before close of business. Need ample time each day to fill and bleed air out of system before end of shift(3:30pm). Sprinkler system can not be out of service more then 8 hours. If this is needed fire watch as needed per safety will be supplied by contractor. Must clean area after work has been completed or at end of day. Period of Performance:As soon as practical after award of contract.The Contractor shall provide, with Services for the Installation, Repair, and Maintenance / Testing Sprinkler systems at the VA Illiana Healthcare System 1900 East Main Street, Danville, Il 61832. The result of this market research will contribute to determining the method of procurement. The applicable North American Industry Classification System (NAICS) code assigned to this procurement is 238220 - Plumbing, Heating, and Air-Conditioning Con...
Active Contract Opportunity Notice ID 36C25224Q0518 Related Notice Department/Ind. Agency VETERANS AFFAIRS, DEPARTMENT OF Sub-tier VETERANS AFFAIRS, DEPARTMENT OF Office 252-NETWORK CONTRACT OFFICE 12 (36C252)
General Information
Contract Opportunity Type: Sources Sought (Original)
All Dates/Times are: (UTC-05:00) CENTRAL STANDARD TIME, CHICAGO, USA
Original Published Date: May 21, 2024 09:44 am CDT
Original Response Date: May 29, 2024 03:00 pm CDT
Inactive Policy: Manual
Original Inactive Date: Jul 28, 2024
Initiative: None
Classification
Original Set Aside:
Product Service Code: J063 - MAINT/REPAIR/REBUILD OF EQUIPMENT- ALARM, SIGNAL, AND SECURITY DETECTION SYSTEMS
NAICS Code: 238220 - Plumbing, Heating, and Air-Conditioning Contractors
Place of Performance: VA Illiana Health Care System Danville, IL 61832-5100 USA
Documents
Tender Notice
36C25224Q0518.docx