Procurement Summary
Country: USA
Summary: E14cl4b Biplane Transducer
Deadline: 20 Aug 2026
Posting Date: 20 Aug 2026
Other Information
Notice Type: Tender
TOT Ref.No.: 147567420
Document Ref. No.: 36C25726Q0689
Competition: ICB
Financier: Self Financed
Purchaser Ownership: Public
Tender Value: Refer Document
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_details
Login to see detailsTender Details
Extension of Sources Sought
This market research notice is being conducted by Network Contracting Office (NCO) 17- VA South Texas (VASTHCS) facilities. The VA North Texas Health Care System (VANTHCS) has a requirement to purchase two E14CL4B Biplane Endocavity Transducers with an authorized vendor to supply and deliver the item(s) identified in Table 1 below. Currently Urology Surgical Service has no working Biplane transducers. Due to the critical diagnoses for cancer and the increase of population to provide care for, additional transducers and probes are mandatory. SCOPE OF WORK Item Item Description Quantity 9048 E14CL4B Biplane Endocavity Transducer 2 UA2507 Reprocessing SS Tray For E14CL4B, E10C4 2- Brand name or Equal
Salient Characteristics - E14CL4B Biplane Endocavity Transducer (Brand Name or Equal)
1. Clinical Applications
• Must support Transrectal, Transvaginal, and Urology applications.
2. Frequency & Acoustic Performance
• Frequency range must be 14-4 MHz.
• Focal range must be 3-60 mm.
3. Imaging Modes Required
The transducer must provide all of the following modes:
• B‑Mode
• M‑Mode
• PWD (Pulsed Wave Doppler)
• CFM (Color Flow Mapping), including Color Doppler & Power Doppler
• THI (Tissue Harmonic Imaging)
• CEUS (Contrast‑Enhanced Ultrasound)
• Strain Elastography
• Combination imaging modes
4. Biplane Imaging Requirements
• Must include two arrays (curved array for transverse imaging and linear array for sagittal imaging).
• Must support simultaneous biplane imaging, enabling visualization of two planes at once for needle guidance during biopsy/puncture procedures.
5. Image Field / Sector Requirements
• Transverse sector: 138°
• Expanded sector: 178°
• Sagittal field: trapezoidal, 65 mm wide, plus 2 × 15° expansion
6. Physical / Ergonomic Features
• Must include variable stiffness shaft to improve patient comfort and instrument maneuverability.
• Weight must be appr...
Notice ID: 36c25726q0689
Department/Ind. Agency: veterans affairs, department of
Sub-tier: veterans affairs, department of
Office: 257-network contract office 17 (36c257)
Product Service Code: 6515 - medical and surgical instruments, equipment, and supplies
NAICS Code: 334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing
Inactive Dates: sep 09, 2026
Inactive Policy: manual
Documents
Tender Notice
Documents.zip