Expired Tender USA ICB TOT Ref. 7110196

Dsi Hd-Xi Glucose Monitoring System Tender in USA - 7110196

Tender notice from USA, published on 28 Jun 2016.

Executive Summary

The DEPARTMENT OF HEALTH AND HUMAN SERVICES has issued a Tender notice for the procurement of a Dsi Hd-Xi Glucose Monitoring System in the USA. This Tender notice was published on 28 Jun 2016 and is scheduled to close on 06 Jul 2016, with an estimated Tender value of Refer Document. Interested bidders can access detailed Tender information, eligibility criteria, and complete bidding documents by referencing TOT Ref No. 7110196, while the tender notice number is HHS-NIH-NIDA-SSSA-2016-424 and Register on the platform.

Key facts

Summary
Dsi Hd-Xi Glucose Monitoring System
TOT Ref. No.
7110196
Document Ref. No.
HHS-NIH-NIDA-SSSA-2016-424
Country
USA
Notice type
Tender
Competition
ICB
Publication date
28 Jun 2016
Bid deadline
06 Jul 2016
EMD
Refer Document
Tender value
Refer Document
Purchaser ownership
-
Financier
Self Financed

CPV classification

Purchaser details

Purchaser contact is for registered users

Login to see details

Tender details

Description:

this is a sources sought notice. This is not a solicitation for proposals, proposal abstracts, or quotations. The purpose of this notice is to obtain information regarding the availability and capability of all qualified sources to perform a potential requirement.
This notice is issued to help determine the availability of qualified companies technically capable of meeting the government requirement and to determine the method of acquisition. It is not to be construed as a commitment by the government to issue a solicitation or ultimately award a contract. Responses will not be considered as proposals or quotes. No award will be made as a result of this notice. The government will not be responsible for any costs incurred by the respondents to this notice. This notice is strictly for research and information purposes only.
Background:

glucose is a necessary energy source for the body and for normal brain functioning. Studies that have monitored blood glucose levels do so via blood sampling which is invasive and causes stress to the animal and can lead to physiological changes due to large amount of blood loss especially in small animals. Additionally, depending on the subjects being sampled, glucose may fluctuate from the beginning of your sampling to the end. The dsi glucose monitor allows for continuous blood glucose monitoring which will allow the researcher to determine glucose levels in the blood without repeated blood sampling.
Purpose and objectives:

the specific glucose monitoring system is needed to measure blood glucose and other functions such as body temperature and activity form non-tethered freely moving rats. The objective is to get a precise understanding of how glucose is altered while an animal is experiencing an external event such as feeding, drug administration, or exposure to a specific behavioral context.
Project requirements:

the hd-xg glucose telemetry implant offers a novel solution to obtain continuous, real-time, blood glucose measurements in laboratory animals. Researchers can collect data for 28 days while reducing animal stress and measurement variability commonly associated with glucose test strip measurements.

Product specifications

-c intended species: rat

-c measures blood glucose, body temperature & activity

-c glucose sensor placed in the blood stream

-c sensor sized for rat descending aorta

-c range of 10-750 mg/dl (0.5-42 mmol/l)

-c bi-weekly calibration recommended

-c device weight: 2.2 g

-c device volume: 1.4 cc

-c warranted battery and sensor life: 28 days from time of implant

dsi is the sole provider of a system for continuous glucose monitoring (hd-xg).
Anticipated period of performance:

the system is expected to be delivered 1-4 weeks after award.
Capability statement /information sought:

respondents must provide clear and convincing documentation of their capability of providing the products specificed in this notice. Also, information must be provided in sufficient details of the respondents (a) staff expertise, including their availability, experience, formal and other training; (b) current in-house capability to perform the work; (c) prior completed projects of similar nature; (d) corporate experience and other management capability; and (e) examples of prior completed government contracts, references, and other related information.
The respondent must also provide their duns number, organization name, address, point of contact, and size and type of business (e.g., 8(a), hubzone, etc., pursuant to the applicable naics code and any other information that may be helpful in developing or finalizing the acquisition requirements.
Finally, respondents are also encouraged to provide a general overview of the respondent s opinions about the difficulty and/or feasibility of the potential requirement, and any other information regarding innovative ideas or concepts that may be applicable.
Submission instructions:

one (1) copy of the response is required and must be in microsoft word or adobe pdf format using 11-point or 12-point font, 8-1/2" x 11" paper size, with 1" top, bottom, left and right margins, and with single or double spacing.
The information submitted must be must be in and outline format that addresses each of the elements of the project requirement and in the capability statement /information sought paragraphs stated herein. A cover page and an executive summary may be included but is not required.
The response is limited to ten (10) page limit. The 10-page limit does not include the cover page, executive summary, or references, if requested.
The response must include the respondents technical and administrative points of contact, including names, titles, addresses, telephone and fax numbers, and e-mail addresses.
All responses to this notice must be submitted electronically to the contract specialist and contracting officer. Facsimile responses are not accepted.
The response must be submitted to pamela daugherty, contract specialist, nih/nida/sssa at [email protected]
the response must be received on or before july 6, 2016at 3:00 pm eastern time.
"disclaimer and important notes:

his notice does not obligate the government to award a contract or otherwise pay for the information provided in response. The government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. Any organization responding to this notice should ensure that its response is complete and sufficiently detailed to allow the government to determine the organization s qualifications to perform the work.
Respondents are advised that the government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. After a review of the responses received, a presolicitation synopsis and solicitation may be published in federal business opportunities. However, responses to this notice will not be considered adequate responses to a solicitation.
Confidentiality:

no proprietary, classified, confidential, or sensitive information should be included in your response. The government reserves the right to use any non-proprietary technical information in any resultant solicitation(s)."
triad building loading dock

333 cassell drive

baltimore, maryland 21224

united states
primary point of contact.:

pamela j. Daugherty

[email protected]

phone: 3014802467 general information
66 -- instruments & laboratory equipment

naics code:

334 -- computer and electronic product manufacturing/334516 -- analytical laboratory instrument manufacturing
334 -- computer and electronic product manufacturing/334516 -- analytical laboratory instrument manufacturing

for help: federal service deskaccessibility

added: jun 27, 2016 9:11 am

Documents

Tender Notice
Login to view

Similar tenders

Tender Country TOT Ref. No. Bid deadline
Gis Stx Lgo-23: Windsheild Replacement USA 152639124 18 Nov 2026
Region 8 Laboratory Samplesense Base Modules And USA 152618859 30 Nov 2026
X209 Meltio M600 Laser Metal Wire 3D Printer Fy27 USA 152618848 30 Nov 2026
Radio Detection Kit with Accessories no Alternatives USA 152618831 23 Nov 2026
Test Kit, Micro Sample USA 152618805 23 Nov 2026

USA Public Procurement Intelligence

Frequently asked questions

The bid deadline for Dsi Hd-Xi Glucose Monitoring System was 06 Jul 2016. Bidding is closed.

This tender has been issued by DEPARTMENT OF HEALTH AND HUMAN SERVICES in USA.

The tender value is not disclosed; please refer to the tender document. EMD / bid security details are provided in the tender document.

This tender is Self Financed

The tender is classified under the following CPV code(s): 38900000 - Miscellaneous evaluation or testing instruments.

The tender notice and related documents are listed in the Documents section above. Select a document to view or download it. Please log in or register to access the documents. If you cannot find additional documents in the Documents section, please log in to your account and Send Document Request from your account section.

The TendersOnTime reference is 7110196. The purchaser document reference is HHS-NIH-NIDA-SSSA-2016-424.

See the Similar Tenders section on this page or browse other tenders from USA.

This tender falls under Technology and Equipment in USA. Suppliers in these sectors can track similar USA tenders using CPV-based alerts.