Expired Tender Greece ICB TOT Ref. 23110389

Contract notice: Wind farm Tender in Greece - 23110389

Tender notice from Greece, published on 08 May 2018.

Exeutive Summary

The ??????? ???????? ??????????? ??????????? ????? ?????????, ?? ?????????? ????? ?.?.?. ??????????? ?.?. has issued a Tender notice for the procurement of a Contract notice: Wind farm in the Greece. This Tender notice was published on 08 May 2018 and is scheduled to close on 08 Jun 2018, with an estimated Tender value of Refer Document. Interested bidders can access detailed Tender information, eligibility criteria, and complete bidding documents by referencing TOT Ref No. 23110389, while the tender notice number is 198431-2018 and Register on the platform.

Key facts

Summary
Contract notice: Wind farm
TOT Ref. No.
23110389
Document Ref. No.
198431-2018
Country
Greece
Notice type
Tender
Competition
ICB
Publication date
08 May 2018
Bid deadline
08 Jun 2018
EMD
Refer Document
Tender value
Refer Document
Purchaser ownership
-
Financier
Self Financed

CPV classification

Purchaser details

Purchaser contact is for registered users

Login to see details

Tender details

Object of the contract
Wind farm
Description: Contract notice: Wind farm
Authority Type: Utilities entity
Contact Nature: Works
Procedure: Negotiated procedure
Document: Contract notice
Regulation: European Union, with participation by GPA countries
Award criteria: The most economic tender
CPV code: 31121340, 31121300, 45251160, 09310000, 45232220, 31682540, 31121340, 31121300, 45251160, 09310000, 45232220, 31682540
CPV Description: (1) wind farm with a capacity of 30 MW and the installation, commissioning, installation and commissioning of a wind farm. 400/20 kV ultra high voltage center of 100 MVA closed-type (GIS) power in the UK. Karditsa.
Reference Number: 0008/18/5300
The PPC Renewables SA, which isthe 100% subsidiary of the Public Power Corporation SA (), invites interested economic operators to a tender procedure, negotiated with a prior call for competition (Article 266, Law 4412/2016), awarding the most economically advantageous tender for the award of a project: the Municipality of Mouzaki and the Municipality Argithea and a (1) ultra high voltage center400/20 kV, 100 MVA closed type, with gas insulated equipment (GIS), in the place Diaselo - Pr. Elias of the Municipality of Mouzaki, Greece Karditsa. The project includes the operation and maintenance of the Wind Park for fourteen (14) years as well as the two (2) Digital Control Systems of the High Voltage Center for 10 (10) years.Mouzakiou, PA The project includes the Aeolian Park at the locations of the Municipality of Mouzaki and the Municipality of Argitheas, with a total capacity of 30 MW and the 400/20 kV 100 MVA closed-type center with gas insulated equipment (GIS) in the place Diaselo - Pr. Elias of the Municipality of Mouzaki, Greece Karditsa. The Wind Park will consist of seven (7) to fifteen (15) wind turbines(A / C) of a total capacity of 27.0 MW to 30.0 MW. The location of the CA, the number and the nominal power of the A / C, as well as the attributable (range) and the maximum possible installed capacity of the installation to be installed are detailed in Table 1, Issue 1. The project's scope includes: Design, study, industrialization, manufacture, supply, factory testingtransport and storage at the place of installation of the equipment, its assembly, construction, installation, on-site testing, commissioning of equipment, supply of spare parts (for the CTV only), operation and maintenance of the CA for fourteen (14) years with the signing of an agreement for the operation and maintenance of the CA and CYT for ten (10)) years with the signing of a maintenance contract for the two (2) Digital Control Systems (CIS) of the CTV. Furthermore, the provision of all the necessary technical services, the design, the study and the construction of the necessary infrastructure works, ie the Electrical and Civil Engineering projects, as well as all the necessary auxiliary facilities, the implementation of the Supervisory Control Systemmeasurement of the power curve of a CA wind turbine, calculation of the availability of the CA, full training of the personnel, monitoring of the operation of the computer system and special software, monitoring and continuous monitoring of its operation from a long to 24 hour period, of the Contracting Authority, the connection of the CA and the CYT to the grid and, finally, - The W / C to be installed in the CA will be the production of one (1) manufacturer with a rated power of between 2.0 and 4.2 MW. Up to two (2) types of A / C will be installed in the A / C, - no change in the location of A / C of CA is limited to maps and topographical charts included in Issue 5, - the maximum cumulative height of the tower (pillar) and tthe blade radius of the offered A / C can not be more than one hundred and fifty (150) meters; - the distance between the A / C of the CA must not be less than two and a half (2.5) times the diameter of the blades A / C, - the offered A / C must be a horizontal axle, with three blades, a steel-hollow-tubular tower and access to the Wagon's shaft only internally from the tower-- the minimum annual guaranteed availability of each A / C will be greater than or equal to eighty five percent (85%), - the minimum guaranteed annual availability of each W /
- the W / Cs to be built and installed in the project will be certified according to IEC 61400-1 and IEC WT 01: 2001 or other equivalent certificate.
The CTV is made up of the High Voltage (CTV-400kV) equipment and power and MV equipment, the limits of which are described in detail in the Connection Agreement. The Contractor will construct two (2) building complexes. A detailed description of the projects is given in the Technical Description of the CWT, which is included in the Tender Documents (Issue 4 - Technical SpecificationsThe registration in a professional register is foreseen, and in particular, the presentation of justification and representation documents in art. • The average of the tenderer's turnover or, in the case of a cartel, at least one (1) of the participating companies in the last three years, should not be less than 50 % of total budgetof the project (not including the service and maintenance service budget)
Internet address (URL): http://www.ppcr.gr
Directive: Classical Directive (2014/25/EU)

Documents

Tender Notice
Login to view

Similar tenders

Greece Public Procurement Intelligence

Frequently asked questions

The bid deadline for Contract notice: Wind farm was 08 Jun 2018. Bidding is closed.

This tender has been issued by ??????? ???????? ??????????? ??????????? ????? ?????????, ?? ?????????? ????? ?.?.?. ??????????? ?.?. in Greece.

The tender value is not disclosed; please refer to the tender document. EMD / bid security details are provided in the tender document.

This tender is Self Financed

The tender is classified under the following CPV code(s): 31121340 - Wind farm, 31121300 - Wind-energy generators, 45251160 - Wind-power installation works, 09310000 - Electricity, 45232220 - Substation construction work, 31682540 - Substation equipment.

The tender notice and related documents are listed in the Documents section above. Select a document to view or download it. Please log in or register to access the documents. If you cannot find additional documents in the Documents section, please log in to your account and Send Document Request from your account section.

The TendersOnTime reference is 23110389. The purchaser document reference is 198431-2018.

See the Similar Tenders section on this page or browse other tenders from Greece.

This tender falls under Defence and Security, Construction and Real Estate, Power and Energy in Greece. Suppliers in these sectors can track similar Greece tenders using CPV-based alerts.