Contract notice: Navigation equipment Tender in Bulgaria - 17955064
Tender notice from Bulgaria, published on 03 Nov 2017.
Executive Summary
The МБАЛ „СВЕТА МАРИНА“ ЕАД has issued a Tender notice for the procurement of a Contract notice: Navigation equipment in the Bulgaria. This Tender notice was published on 03 Nov 2017 and is scheduled to close on 07 Dec 2017, with an estimated Tender value of Refer Document.
Interested bidders can access detailed Tender information, eligibility criteria, and complete bidding documents by referencing TOT Ref No. 17955064, while the tender notice number is 437897-2017 and Register on the platform.
Object of the contract Navigation equipment Description: Contract notice: Navigation equipment Authority Type: Other Contact Nature: Supplies Procedure: Open procedure Document: Contract notice Regulation: European Union Award criteria: Lowest price CPV code: 34933000, 34933000, 34933000 CPV Description: Navigation equipment - Delivery of equipment for performing neurosurgical interventions and procedures for deep brain stimulation for the needs of Sveta Marina EAD - The subject of the order includes: Main Site: Clinic of Neurosurgery at St. Marina Marina University EAD, is located at Varna, 1. "Hristo Smirnenski" Blvd. I. Navigation system-1 Navigation system with 2 monitors, one of thebut is used by service providers. staff, etc. monitor with hi. resolution and sensation. screen to be used by an operator. 2. Navigation. syst. have a built-in emergency battery. power supply. 3. Have CD, USB memory or h / network supporting DICOM format. 4. Sit. to work with an electromagnet. and optic. instruments / instrument. for navigation. 5. Have a cranial appliqu- for application with an easily accessible squarevisualization and visualization of the cortical surface, veins and ventricles to perform head surgery. 6. Have a Combination of Differentiation. data modalities with images such as CT and MRI, and fusion with intraoperative imaging data.7.There is a set of navigation tools for performing a opt head operation. navigation. 8. Have a set of liabilities, k. to allow calibrationand navigating a surgeon. instr. 9. Have a set of instructions. to carry biopsy with navigation, with biopsy guide, fixed on outer arm. 10 There is a set of instructions for conducting biopsy with navigation, without external arm, with fix. driver mounted on the skull for a single crown. passive probe, screwdriver, ext. and inside. base, serv. channel, lock. ring. 11. It is in the system to use a flexible electromag. Navigation during a cranial cranial operation with a ventricular catheter. 12. Ability to integrate a navigational system with a surgeon. microscopy.13To apply a vertebrate application to allow navigation based on preoperative CT, integration and autoimmunity. regression of a patient with intraoperative imaging system.14. Have a full set of navigations. inbackbone operations, including open and minimal invasive approaches.15. Application for ENT Application for navigation in endoscopic sinus surgery, based on the skull, to work on an electromagnet. principle of action with the necessary set of tools. (flexible socket, electromagnetic pointer). 16. Station for planning of DMD procedures. 17. Amount for DBP (app. based on CTand MRI images plan the coordinates for inserting target electrodes and define optimum. electrode path. 18. Amount of transmission of numerical data obtained in the process of electrodes insertion planning of the stereotactic frame. 19. Application for complex visualization and planning of a surgeon. procedures. 20. With a flexible socket in the middle. size. 21. Have a set of supplies, k. to include an electromag. probes, passive markers and biopsy. needles, flexible suction for a minimum of 10 procedures. Stereo-stereo system based on stereo contact. and functional neurosurgery-1. Stereo contact. you need to. to be arc-centered and based on the Cartesian coordinate system.2 The Cartesian coordinate. The system must correspond to the X, Y, and Z nomenclatures used in CT and MRI scanning. 3. Pr. the system has a sterilization tray for the frame and the arch with a specific. nesting pockets. elements. 4. components of the stereotactic system must include a Cartesian coordinate frame and a semicircular arch. 5. Digital. Coordinate strings are engraved in the frame and the arch and are in millimeters. 6. The semicircular arch must turn on. sliding tool carrier. to work withInstruments such as needles, electrodes and other microsurgical instruments. 7. The frame and the arch must be able to hold more than one tool holder, allows you to reach a selection. Target with 2 or more trajectories. 8. Stereo contact. the system should allow. fix. positioning the patient during CT and MRI scanning for examinations and identifying exactly the same. of the target. 9. Base. frame t-bva btogether. with X-ray, CT and MRI. 10. Stereo contact. the system should attach the arch to the frame in the lateral (right / left or left / right) and sagital (front / back) or back / front orientation. 11. Stereo. the system should have the capability to use screws to fix it to the skull for a multitude. use. The screws must be made of a material that allows them to be usedand CT and / or MRI.20 pairs of screws for multi-use fixation 1. According to Art. 77 of the LMI, the participant shall hold a permit for wholesale trade in medical devices on the territory of the Republic of Bulgaria issued by BDA or other documents at the discretion of the participant, proving that he has the right to carry out wholesale trade in medical devices on the territory of the Republic Bulgaria, issued by cocompetent authority of the country concerned Proof: If the tenderer designated as a contractor is a Bulgarian economic operator, the contracting authority does not require the submission of the documents referred to in paragraph 1 in paper form, in view of the fact that the register is public. the person proves the fulfillment of the requirements in the cases under Art. 67, para. 5 and 6 of the Public Procurement Act, by presenting copies of the possessed by Mr.ego documents The Employer has no requirements regarding the economic and financial status of the participants Additional Requirements: 1. The equipment should: (a) be new and unused. for a demonstrator. objectives; (b) be manufactured. not earlier than 12 months before the date of its delivery, (c) be certified under Directive 93/42 / EEC and bear the CE marking, with requiredArt. 8 and Art. 15 of the MIR; (d) have a conformity record drawn up by the manufacturer or by his authority. representative under Art. 14, para. 2 of the MIP. Avg. delivery, installation and commissioning of the Apparatus - up to 120 cal. days from the date of receipt of the letter. Purchase Request from the Contracting Authority. Installation and installation of an apparatus should be carried out by a technician, which have a corresponding. qualifications and experience. The training of staff to work with the Apparatus should be done immediately after it has been put into operation. Gar. the duration of the apparatus shall not be less than 12 months from the date of the two-year period. signed commissioning protocol. The Device Bar should include: 5.1.prophylaxis, depending on the requirements of the manufacturer's plant(if so provided) 5.2.clearing of all technical failures that have not occurred due to the fault of the assignor 5.3 software updates (if so provided) 6. The contractor should ensure the full function. suitability of the apparatus according to its purpose, Tech. specification and technical standards for safety and security. The Contractor shall remove his / her own powerand also funds all equipment problems, proff. guardian. conditions and Tech. proposal for execution of the order .. 8. During the term of the term, in the case of an established problem on the apparatus, the Contractor shall send his / her qualification. representatives of the place for finding and identifying the damage within a term not longer than 3 days from receipt of the advertisement of the contracting authority sent by fax, e-mail or regular mail.When the customer service visit, the Contractor's team should be established. protocol of the technical service performed, the type of damage, the work and the time needed for the removal. the Contractor shall remedy the damage occurring within 3 working days. days, insight. from the date of the finding of the damage, as per item 8. If unable to remove theIf a failure occurs within 5 working days, the Contractor should replace a defect. a part of a new one of the same or a similar class which he undertakes to install and put into service under the same terms and conditions of performance as those offered in the "Proposal for performance of the contract" as the title of the apparatus should be extended by the term, p / h that has been removed by the fault / replacement. Employerthe participant withdraws from participation in the procedure: 1. for whom the grounds under Art. 54, para. 1 and Art. 55, para. 1, item 1 of the Public Procurement Act, occurring before or during the procedure; does not meet the selection criteria set or fails to fulfill another condition specified in the general notice. order or in the documentation; k. has submitted an offer that does not meet the pre- the announced terms of the order 4. k. has not submitted the justification under Art. 72, para. 1 of the Public Procurement Act or whose offer has not been accepted, according to Art. 72, para. 3-5 of the Public Procurement Act; Participants who are related Art. 3, item 8 of the ZIFODRIPPDPS; Art. 4, para. 7, in connection with Art. 6, para. 2 of the LMML. 7. The participant declares the lack of grounds-removal and compliance with the selection criteria by submitting the EEDOP 8. The contracting entity requires the designated contractor to provide a guarantee for the duration of the contract at the rate of 5% of its value, exclusive of VAT, to ensure its execution. Internet address (URL): www.svetamarina.com Directive: Classical Directive (2014/24/EU)
The bid deadline for Contract notice: Navigation equipment was 07 Dec 2017. Bidding is closed.
This tender has been issued by МБАЛ „СВЕТА МАРИНА“ ЕАД in Bulgaria.
The tender value is not disclosed; please refer to the tender document. EMD / bid security details are provided in the tender document.
This tender is Self Financed
The tender is classified under the following CPV code(s): 34933000 - Navigation equipment.
The tender notice and related documents are listed in the Documents section above. Select a document to view or download it. Please log in or register to access the documents. If you cannot find additional documents in the Documents section, please log in to your account and Send Document Request from your account section.
The TendersOnTime reference is 17955064. The purchaser document reference is 437897-2017.