Procurement Summary
Country: USA
Summary: Brand Name or Equal 1H Pediatric Head Array for Neonates for Siemens Prisma 3T MR, software version VE11C, P-H32LE-030
Deadline: 25 Sep 2019
Posting Date: 18 Sep 2019
Other Information
Notice Type: Tender
TOT Ref.No.: 36429057
Document Ref. No.: 75N95019Q00344
Competition: ICB
Financier: Self Financed
Purchaser Ownership: -
Tender Value: Refer Document
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_details
Login to see detailsTender Details
Brand Name or Equal 1H Pediatric Head Array for Neonates for Siemens Prisma 3T MR, software version VE11C, P-H32LE-030
Place of Performance .: 251 Bayview Blvd.Baltimore, Maryland 21224 United States
Classification Code:66 -- Instruments & laboratory equipment
NAICS Code:334 -- Computer and Electronic Product Manufacturing/334516 -- Analytical Laboratory Instrument Manufacturing
Notice Type :Combined Synopsis/Solicitation
Posted Date :September 17, 2019
Response Date :Sep 25, 2019 10:00 am Eastern
Archive Date :October 10, 2019
Synopsis: COMBINED SYNOPSIS / SOLICITATIONTitle: Brand Name or Equal 1H Pediatric Head Array for Neonates for Siemens Prisma 3T MR, software version VE11C, P-H32LE-030(i) This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6 as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued.(ii) The solicitation number is 75N95019Q00344 and the solicitation is issued as a request for quotation (RFQ).This acquisition is for a commercial item or service and is conducted under the authority of the Federal Acquisition Regulation (FAR) Part 13-Simplified Acquisition Procedures; FAR Subpart 13.5-Simplified Procedures for Certain Commercial Items; and FAR Part 12-Acquisition of Commercial Items, and is not expected to exceed the simplified acquisition threshold.(iii) The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2019-06, dated September 10, 2019.(iv) The associated NAICS code 334516 and the small business size standard 1, 000 employees. This requirement is full and open with no set-aside restrictions.(v) The National Institute on Aging (NIA) requires the purchase of RF coils that have high sensitivity for fMRI (resting-state fMRI) and DTI and MRS on monkeys in order to conduct fMRI imaging on rhesus monkeys on a Siemens Prisma scanner. RF coils must be compatible with Siemens Prisma and the size suitable for rhesus monkeys (ID
23 cm). The acquisition of an MR pediatric head array will allow for fMRI imaging on rhesus monkeys as this head array is the appropriate size for these subjects.(vi) Generic Name of Product: MR Pediatric Head ArrayBrand Name of Product: Rapid MR 31P 1H Volume Head Coil (Item #: P-H32LE-030)1H pediatric head array for neonatesP-H32LE-030receive-only, actively decoupled32 channel coil arrayfixed tunedanatomical shaped helmet designapproximate dimensions:inner diameter 15 cmouter diameter 20 cmarray length 15 cminterface to Siemens Prisma via four Siemens Tim Coil Interfaces 3TThe coil dimensions are suitable for studies in non-human primate brainsCoil fr...
Documents
Tender Notice