Expired Tender USA ICB TOT Ref. 122752193

AJJY 25-1074M Repair Saipan Dorm B25007 Tender in USA - 122752193

Tender notice from USA, published on 16 Jul 2025.

Executive Summary

The DEPT OF DEFENSE | DEPT OF THE AIR FORCE has issued a Tender notice for the procurement of a AJJY 25-1074M Repair Saipan Dorm B25007 in the USA. This Tender notice was published on 16 Jul 2025 and is scheduled to close on 18 Aug 2025, with an estimated Tender value of Refer Document. Interested bidders can access detailed Tender information, eligibility criteria, and complete bidding documents by referencing TOT Ref No. 122752193, while the tender notice number is FA524025R0004 and Register on the platform.

Key facts

Summary
AJJY 25-1074M Repair Saipan Dorm B25007
TOT Ref. No.
122752193
Document Ref. No.
FA524025R0004
Country
USA
Notice type
Tender
Competition
ICB
Publication date
16 Jul 2025
Bid deadline
18 Aug 2025
EMD
Refer Document
Tender value
Refer Document
Purchaser ownership
Public
Financier
Self Financed

Purchaser details

Purchaser contact is for registered users

Login to see details

Tender details

Description
Andersen Air Force Base, Guam has a Design-Build construction requirement to design and fully repair Saipan Dorm B25007
DESCRIPTION OF WORK
The contractor shall design and fully repair Saipan Dorm B25007 to renovate interiors including floors, walls, ceiling, finishes, full restroom renovation, updating code for Energy and Life Safety, exterior renovations resulting from recent storm damage. Walkway slabs and spandrel beams will be repaired. Repairs will also include a complete update to the HVAC and Plumbing systems. B25007 is conditioned by chilled water and a central chiller plant, and both will be replaced. A complete replacement of air handlers, ductwork, grilles, variable air volume boxes, and chilled water piping will be replaced. The chilled water pump will be replaced. All existing plumbing utilities will be replaced and updated. The existing heat pump water heaters will be replaced with standard electric water heaters with large storage tanks. Electrical updates include an update to the entire electrical distribution system. The system updates will include a complete replacement of electrical distribution from the pad mount transformer secondary conductors to the entire downstream building distribution system. Fire protection updates include sprinkler protection throughout, installation of a mass notification system, and a wet-pipe sprinkler system throughout the dorm. B25007 must be re-graded to maintain positive drainage away from the building. Existing storm sewer inlets buried with debris, dirt, and grass are to be cleared.
MAGNITUDE FAR 36.204(h) and DFARS 236.204(ii)
The magnitude of this project is between $25, 000, 000 - $100, 000, 000
LOCATION OF WORK:
Andersen AFB, GU
PERIOD OF PERFORMANCE
865 Calendar Days
RESTRICTION TO SMALL BUSINESS:
This acquisition is being competed as a Historically Underutilized Business Zone (HUBZone) Small Business set-aside. The applicable Nor...
Active Contract Opportunity

Notice ID : FA524025R0004

Related Notice

Department/Ind. Agency : DEPT OF DEFENSE

Sub-tier : DEPT OF THE AIR FORCE

Major Command : PACIFIC AIR FORCES

Office: FA5240 36 CONS LGC

General Information

Contract Opportunity Type: Solicitation (Updated)

Updated Published Date: Jul 16, 2025 03:05 pm AEST

Original Published Date: Jul 16, 2025 02:42 pm AEST

Updated Date Offers Due: Aug 18, 2025 02:00 pm AEST

Original Date Offers Due: Aug 18, 2025 02:00 pm AEST

Inactive Policy: Manual

Updated Inactive Date: Jul 16, 2026

Original Inactive Date: Jul 16, 2026

Initiative: None
Classification

Original Set Aside: Historically Underutilized Business (HUBZone) Set-Aside (FAR 19.13)
Product Service Code: Z2FC - REPAIR OR ALTERATION OF TROOP HOUSING FACILITIES

NAICS Code: 236220 - Commercial and Institutional Building Construction
Place of Performance: Andersen AFB, Guam Yigo, GU USA

Documents

Tender Notice
Login to view
Solicitation-FA524025R0004.pdf
Login to view
Attachment-1-Statement-of-Work-AJJY-25-1074M-Repai.pdf
Login to view
Attachment-1A-AAFB-Contractor-Antiterrorism-Awaren.pdf
Login to view
Attachment-1B-36-CES-Contractors-Builder-Inventory.xlsx
Login to view
Attachment-1C-AJJY-25-1074M-Repair-Saipan-Dorm-B25.pdf
Login to view
Attachment-1D-AJJY-25-1074M-Repair-Saipan-Dorm-B25.pdf
Login to view
Attachment-1E-AJJY-25-1074M-Repair-Saipan-Dorm-B25.pdf
Login to view
Attachment-1F-19960111-B25007-Jacobs-Asbestos.pdf
Login to view
Attachment-1G-201307-B25007-Report-B-Asbestos-and.docx
Login to view
Attachment-1H-201307-B25007-Report-A-Asbestos-and.pdf
Login to view
Attachment-1I-USAF-Fire-Alarm-Panel-Approval-Memor.pdf
Login to view
Attachment-1J-Cat-Management-4-HVAC-Standardizatio.pdf
Login to view
Attachment-2-Project-Requirement-Price-Schedule.docx
Login to view
Attachment-3-Past-Performance-Fact-Sheet-PPFS.docx
Login to view
Attachment-4-Past-Performance-Questionnaire-PPQ.docx
Login to view
Attachment-5-AAFB-IFS_27FEB24.pdf
Login to view
Attachment-6-Wage-Determination-GU20250001.pdf
Login to view
Attachment-7-Common-Construction-Prevailing-Wage-R.pdf
Login to view
Attachment-8-PIEE-Proposal-Manager-Reference-Guide.pdf
Login to view

USA Public Procurement Intelligence

Frequently asked questions

The bid deadline for AJJY 25-1074M Repair Saipan Dorm B25007 was 18 Aug 2025. Bidding is closed.

This tender has been issued by DEPT OF DEFENSE | DEPT OF THE AIR FORCE in USA.

The tender value is not disclosed; please refer to the tender document. EMD / bid security details are provided in the tender document.

This tender is Self Financed

The tender notice and related documents are listed in the Documents section above. Select a document to view or download it. Please log in or register to access the documents. If you cannot find additional documents in the Documents section, please log in to your account and Send Document Request from your account section.

The TendersOnTime reference is 122752193. The purchaser document reference is FA524025R0004.

Browse other tenders from USA or search by relevant keywords and CPV classification.