Tender are invited for 44, 113 CY excavation; 1, 056 CY structure excavation; 1, 290 CY porous granular embankment; 10, 684 CY trench backfill; 96, 789 SY geotechnical fabric for ground stabilization; 6, 007 CY topsoil excavation and placement; 57, 987 SY erosion control blanket; 10, 103 FT perimeter erosion barrier; 96, 789 SY aggregate subgrade improvement; 2, 132 ton HMA surface course; 30, 188 lb bituminous materials prime; 3, 005 lb bituminous materials tack; 89, 201 SY PCC pavement; 16, 036 SY aggregate base course; 2, 579 SY PCC driveway pavement; 34, 513 SF PCC sidewalk; 1, 163 SF detectable warnings; 72, 101 SY pavement removal; 6, 487 SY HMA removal; 1, 986 SY driveway pavement removal; 13, 917 FT curb and gutter removal; 13, 740 SF sidewalk removal; 304 CY cofferdam excavation; 1 cofferdam (type 2); 290, 220 lb structural steel; 8, 757 stud shear connectors; 259, 253 lb rebar, epoxy coated; 1, 130 FT furnishing steel piles; 3, 268 FT furnishing soldier piles; 20, 900 FT pipe underdrains; 23, 639 FT concrete curb and gutter; 14, 300 CY non-special waste disposal; 600 cal da traffic control surveillance; 1, 455 SF preformed plastic pavement marking, type B - letters and symbols; 10, 810 FT preformed plastic pavement marking, type B - line; 941 SF polyurea pavement marking type 1 - letters and symbols; 171, 811 FT polyurea pavement marking type 1 - line; 14, 350 FT underground conduit; 4, 268 LF electric cable in conduit; 18 luminaire, sodium vapor, horizontal mount, 400 watt; 65, 507 LF electric cable in conduit; 69 signal head, polycarbonate, LED; 32 traffic signal backplate; 105 inductive loop detector; 14, 569 LF detector loop; 88 LF box culvert removal; 22, 938 SF noise abatement wall, ground mounted; 5, 310 SF noise abatement wall, structure mounted; 43, 325 SF pavement marking removal - water blasting; 242 FT precast concrete box culverts 12` x 9` (special); 217 CY granular backfill for structures; 1, 502 SF grooving for recessed pavement marking, letters and symbols; 66, 841 FT grooving for recessed pavement marking; 6 full actuated controller and type IV cabinet, special; 1, 915 LF electric cable in conduit no. 20 3/c, twisted, shielded; 302 LED signal face retrofit; 995 LF pipe underdrains for structures; 3, 608 SY temporary pavement; 4 precast box culvert end sections; 8, 848 LF fiber optic cable in conduit; 4, 793 SF form linear textured surface (special).
Notes : DBE goal - 9%. Additional POCs : Carrie Kowalski at
[email protected]; Tim Garman at 217-524-1642 or
[email protected]; Ted Walschleger at 217-782-4894
[email protected]. The prequalification cut-off date is 4 : 30 p.m. prevailing time May 26, 2017. To be eligible to bid, existing prequalification ratings must be effective through the date of letting. The Joint venture cut-off date is 4 : 30 p.m. prevailing time June 9, 2017. The Authorization to Bid request cut-off dat...