Procurement Summary
Country: USA
Summary: 589A425102, Install Dedicated Pharmacy Air Handler
Deadline: 08 Sep 2026
Posting Date: 25 Jul 2026
Other Information
Notice Type: Tender
TOT Ref.No.: 145942531
Document Ref. No.: 36C25526R0159
Competition: ICB
Financier: Self Financed
Purchaser Ownership: Public
Tender Value: Refer Document
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_details
Login to see detailsTender Details
THIS IS A PRESOLICITATION NOTICE ONLY
PRESOLICITATION NOTICE- Install Dedicated Pharmacy Air Handler
Project Number 589A4-25-102
Scope of work:
The Harry S Truman Veterns Memorial Hospital in Columbia, MO requires the installation of three dedicated air handling units (AHUs) to bring the pharmacy and compounding, located in building one, in compliance with the latest VA HVAC Design Manual. The air handlers will serve the compounding area on the third floor, and the pharmacy and compounding areas in the basement.
The project design includes a new dedicated DOAS located in E002B in the Basement to serve the Compounding Suite in the Basement. There will be two new dedicated Air Handling Units in a new Mechanical space in the Southeast corner of the Second Floor Roof.
Construction Phasing
Installation of the new mechanical equipment will precede the demolition of the existing units. Temporary units will be provided for service while the first existing Mechanical units is demolished and removed. The same procedure will occur for the remainder of the Mechanical units.
Selective Mechanical Demolition
The main supply and return trunks serving the pharmacy and compounding areas in the basement will be demolished back to the plenum. The plenum will be patched and repaired. All but one VAV terminal units will remain in place. One VAV will be removed and prepared for relocation. The supply trunk supplying the compounding areas on the third floor will be partially demolished back to the last VAV on the trunk. Also, the supply trunk supplying the air flow control valves will require a partial demolition.
Proposed Mechanical System Description
There will be a new dedicated DOAS located in room E002B in the basement to serve the compounding suite in the basement. This AHU will be 4000 cfm with a chilled water cooling coil, steam heating coil, duct mounted humidifier, supply fan, two duct mounted pre-filters, a duct mounted after filter, and ...
Notice ID: 36c25526r0159
Department/Ind. Agency: veterans affairs, department of
Original Set Aside: service-disabled veteran-owned small business (sdvosb) set-aside (far 19.14)
Sub-tier: veterans affairs, department of
Office: 255-network contract office 15 (36c255)
Product Service Code: z2da - repair or alteration of hospitals and infirmaries
NAICS Code: 236220 - Commercial and Institutional Building Construction
Inactive Dates: dec 07, 2026
Inactive Policy: manual
Documents
Tender Notice
Documents.zip