Procurement Summary
State: Maharashtra
Summary: Tender For Cleaning Of Hsd Tank (Tk11) At Muzaffarpur Depot
Deadline: 31 Jan 2019
Posting Date: 25 Jan 2019
Other Information
Notice Type: Tender
TOT Ref.No.: 30111823
Document Ref. No.: CRFQ No.- 1000323852
Financier: Self Financed
Purchaser Ownership: -
Document Fees: Refer Document
Tender Value: Refer Document
EMD: Refer Document
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_details
Login to see detailsTender Details
Tender For Cleaning Of Hsd Tank (Tk11) At Muzaffarpur Depot
Tender For Cleaning Of Hsd Tank (Tk11) At Muzaffarpur Depot. Details And Scope Of Job As Per Crfq No.-1000323852.Scope Of Job Cleaning Of Cone Roof Ag Tank (10.5 M Dia X 10 M Height, Capacity 870 Kl ) At Muzaffarpur Depot."Removing Of Dead Stock (Oil) Will Start Below Suction Level Of Tlf Pump."Only Certified Non-Sparking Tools Will Be Allowed For Execution Of This Job"All The Electrical Equipments And Connection Will Be Flp Type."Delivery Date For Tk11 (Hsd) Tank Will Be 20.02.2018.""Tank Details -Tank -Tk11(Hsd)Type -Cone Roofdia-10.5Mhight-10.0Mcapacity-870 Kl1.Removal Of Sludge From Tank By Safe Method And Dump The Sludge In Sludge Pits/ Bio Remediation Pit Made At Site Or Barrels Provided By Bpcl And Stack Them At The Place As Per Procedure And As Advised By Engineer In-Charge. Records To Be Maintained For The Same.2.Coarse And Fine Cleaning Of Bottom Plates And Shell Upto 2 Mtrs/2.5 Mtrs( Upto First Shell) Height Using Manual / Explosion Proof Hydro Jetting Machine As Per Procedure And As Advised By The Engineer In-Charge. Records To Be Maintained For The Same.3. Rates Are Inclusive Of Mobilization/Demobilization Of Machine And Manpower Etc Complete.Procedure To Be Followed During Tank Cleaning Work Permithot Work Permit To Be Taken Before Starting Of Work And Permit To Be Renewed Every Day. Ensure That The Precautions Are In Place As Laid Down In The Permit And No Relaxation. Fresh Permit Is To Be Obtained Once In Every 7 Days And Old Permit Should Be Closed." Display Warning Boards, Fence The Area Of Operations.Ventilation Of Tanks -1.Ventilate The Tank To Bring Down Vapour Concentration Below Lel2. Petroleum Vapours Are Heavier Than Air; Hence It May Require Forced Ventilation.3. Duration Of Ventilation Depends Upon The Wind Strength And Direction.4. After The Period Of Ventilation, Monitoring To Be Carried Out For Gasoline Vapour, Tel Vapour From Sludge Poses Toxic Hazards.5. During Thunder And Lightening Suspend Work And Close All Opening.6. Methods Of Forced Ventilation" Wind Sailing" Air Blowing" Air Extractionflame Proof Fitting Should Be Used For Forced Ventilation.Mask Areamask Area Is The Zone In And Around The Tank Where Breathing Apparatus Is To Be Worn To Prevent Inhalation Of The Lethal Vapour. It Is Considered To Be 5 Metres All Around The Tank And An Additional 30 Metres Downwind.Leaving The Mask Area1. On Coming Out Of The Manhole, The Worker Should First Step In A Steel Plate Positioned Just Outside.2. He Should Then Step Into A Tray Where The Dress Or Should Wipe Down His Equipment And Clothing With A Rag On Brush Soaked In Kerosene.3. For Going Out Of The Mask Area For A Short Break, His Gloves, Boots And Breathing Apparatus Should Be Removed By The Dresser.4. If The Break Is For A Longer Duration, As In Case Of Lunch, His Entire Ppe To Be Removed, And He Sh
Documents
Tender Notice