Open for bids Tender India NCB TOT Ref. 152770993

Supply Laying Testing Cable Xlpe Insulated Tender - 152770993

Tender notice from India, published on 20 Nov 2026.

Executive Summary

The INDIAN ARMY has issued a Tender notice for the procurement of a Supply Laying Testing Cable Xlpe Insulated Screened Pvc Bedded Galvanized Steel Strip 11000 Volts G, Qty: 3311 in the India.The project location is Bardhaman, West Bengal, India. This Tender notice was published on 20 Nov 2026 and is scheduled to close on 30 Nov 2026, with an estimated Tender value of Refer Document. Interested bidders can access detailed Tender information, eligibility criteria, and complete bidding documents by referencing TOT Ref No. 152770993 and Register on the platform.

Key facts

Summary
Supply Laying Testing Cable Xlpe Insulated Screened Pvc Bedded Galvanized Steel Strip 11000 Volts G, Qty: 3311
TOT Ref. No.
152770993
Document Ref. No.
Login to see
City
Bardhaman
State
West Bengal
Notice type
Tender
Competition
NCB
Publication date
20 Nov 2026
Bid deadline
30 Nov 2026
EMD
Refer Document
Tender value
Refer Document
Purchaser ownership
Public
Financier
Self Financed

CPV classification

Purchaser details

Purchaser contact is for registered users

Login to see details

Tender details

Tender details are for registered users

Login to see details

Documents

Tender Notice
Login to view
Bid_Document_10171761.pdf
Login to view
Specification_Document.pdf
Login to view
BOQ_Document.csv
Login to view

Bill of Quantities (BOQ)

# Title Description Qty Unit Delivery (Days)
1 Supply laying testing cable XLPE insulated screened PVC bedded galvanized steel strip 11000 volts grade of size 3 core 95 sq mm Supply laying testing cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables heavy dutywith stranded aluminium conductor11000 volts grade of size 3 core 95 sq mm. 340 RM 90
2 ML cable jointing kit for 11 KVEarthed grade cable for outdoor terminal heat shrink XLPE armoured Al conductor cable of size 50 to 95 sq mm ML cable jointing kit for 11 KVEarthed grade cable for outdoor terminal heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 50 to 95 sq mm complete all as specified and as directed. 2 Each 90
3 Supply and install HT 11 KV out door type gang operated air break switch suitable for horizontal or vertical triple pole for current rating up to 400 Amps complete all as specified and as directed Supply and install HT 11 KV out door type gang operated air break switch suitable for horizontal or vertical triple pole mechanically operated mounted on insulator and steel frame with operating mechanism worked from ground level for current rating up to 400 Amps complete all as specified and as directed. 2 Each 90
4 M L lightning arresters expulsion type Complete with all fittings transmission classsuitable for 11KV discharge capacity 65 kilo amp complete all as specified and as directed. M L lightning arresters expulsion type Complete with all fittings transmission classsuitable for 11KV discharge capacity 65 kilo amp complete all as specified and as directed. 2 Set of 3 90
5 Material and labour for earthing complete with electrodes of size 600mm x 600mm x 6mm thick buried directly in ground not less than 2.25m deep below iron pipe 40 mm bore Material and labour for earthing complete with galvanized steel plate electrodes of size 600mm x 600mm x 6mm thick buried directly in ground with earth pit not less than 2.25m deep below normal ground level with top edge of plate not less than 1.5 m below normal ground level connected to galvanized strip of 32 mm x 6 mm earth lead by means of nuts bolts check nuts GI washers earth wire protected by galvanized iron pipe 40 mm bore light grade including concrete pit in PCC 136 type CI precast RCC cover slab of size 30x30x10 cm with one handle for lifting made out of 8 mm dia MS bar funnel wire mesh 20 mm bore galvanized iron pipe medium grade for watering charcoal or coke and salt in alternate layers necessary earth work in softloose soil complete all as shown in electrical plate No 3 of SSR part 1 including testing on completion all as specified and directed. 10 Each Set 90
6 Supply Erecting Steel Tubular Swaged Pole Type 410SP55 11.0 Metre long including Cast Iron Base Plate Finial Taper Plug Cap Mild Steel Bolts Supply Erecting Steel Tubular Swaged Pole Type 410SP55 11.0 Metre long including Cast Iron Base Plate Finial Taper Plug Cap Mild Steel Bolts Nuts Screws including applying two coats of Black Bituminous Paint Internally and Externally from bottom End of Pole upto PCC Coping and applying with two coats of Aluminium Painting over a coat of Aluminium Primer Externally from Top of Coping complete all as specified and as directed. 4 Each 90
7 M L cross arms bracings supports clamps and back plates fabricated from structural steel sections including nuts bolts washers welding bending cold or hot M L cross arms bracings supports clamps and back plates fabricated from structural steel sections including nuts bolts washers welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat one under coat and one finishing coat of paint complete all as specified and as directed. 5 Qtl 90
8 ML for PCC 136 type C2 using 40 mm graded aggregate as in foundation for pole etc complete all as specified and as directed ML for PCC 136 type C2 using 40 mm graded aggregate as in foundation for pole etc complete all as specified and as directed. 5 Cum 90
9 ML for PCC 124 type B1 using 20 mm graded aggregate as in coping for pole including form work and finishing the surfaces even and smooth etc complete all as specified and as directed. ML for PCC 124 type B1 using 20 mm graded aggregate as in coping for pole including form work and finishing the surfaces even and smooth etc complete all as specified and as directed. 1 Cum 90
10 Supply and fix Pin insulator porcelain vitreous 11000V grade 150mm high 150mm dia nuts bolts and washers etc Supply and fix Pin insulator porcelain vitreous 11000V grade 150mm high 150mm dia nuts bolts and washers etc galvanised MS spindle washers fixed on channels or directly on poles all as specified and as directed by EngineerinCharge. 12 Each 90
11 Supply and fix Disc type insulator porcelain vitreous 145mm high and 255mm dia ball and socket type 11000 volts Supply and fix Disc type insulator porcelain vitreous 145mm high and 255mm dia ball and socket type white brown or green Twoinseries pressure 11000 volts all as specified and as directed by EngineerinCharge. 6 Each 90
12 SF Aluminium Conductor Steel Reinforced Sags and providing Jumper SF Aluminium Conductor Steel Reinforced ACSR sizes as ordered with permissible Sags and providing Jumper etc. complete all as specified and as directed. <br> 1 Qtl 90
13 ML for 32 6mm galvanised iron strip including connection from earthing in continuation to end point complete all as specified and as directed ML for 32 6mm galvanised iron strip including connection from earthing in continuation to end point complete all as specified and as directed by EngrsinCharge. 36 RM 90
14 Supply Install transformer 100KVA 110.433 kv 3 phase 50 Hz 63 mm graded aggregate deposited Supply Install transformer 100KVA 110.433 kv 3 phase 50 Hz onan cooled oil immersed copper wound outdoor type step down transformer complete with first filling of is 335 isi marked filtered dehydrated transformer oil and other standard fittings accessories and 7 position off circuit tap changer tapping range +7.5% in steps of 2.5% each with vector group dyn11 and EEL 2 of IS 1180 Part12014 with amd. no. 123 4 complete all as specided and directed. Make ITE Note RCC Foundation for Transformer as OEM recommendationgravel for gauge n exc. 63 mm graded aggregate deposited spread in levelled in layers not exceeding 15cm thick rammed to true surface and Cattle fencing 1.5m high around is included in above rates. 1 Each 90
15 Material and Labour RCC cable route indicator of size 1300 300 100 mm duly written HT CABLE in block letter duly engrave as MES and painted Material and Labour RCC cable route indicator of size 1300 300 100 mm duly written HT CABLE in block letter duly engrave as MES and painted with synthetic enamel paint over one coat of primer and fixing with PCC 136 C2 using 40 mm graded stone in 600 450 300 mm for fixing route indicator complete all as specified and directed. <br>. 10 Each 90
16 Supply laying and testing cable XLPE Insulated screened PVC beddedgalvanized steel strip or wire armoured 70 sq mm 3.5 core Supply laying and testing cable XLPE Insulated screened PVC beddedgalvanized steel strip or wire armoured electric power cables heavy duty 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core 30 RM 90
17 Supply laying and testing cable XLPE Insulated screened PVC beddedgalvanized steel strip or wire armoured heavy duty 1100 Volts grade size 16 sq mm 4 core. Supply laying and testing cable XLPE Insulated screened PVC beddedgalvanized steel strip or wire armoured electric power cables heavy duty 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core. 305 RM 90
18 Supply laying and testing cable XLPE Insulated screened PVC beddedgalvanized steel strip Supply laying and testing cable XLPE Insulated screened PVC beddedgalvanized steel strip or wire armoured electric power cables heavy duty 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core. 168 RM 90
19 Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth getting out in Soft Loose Soil complete all as specified and as directed Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth getting out in Soft Loose Soil complete all as specified and as directed. 236 CUM 90
20 Returning Filling in including Spreading Levelling Watering and Well Ramming in Layers not exc. 250mm in SoftLoose Soil complete all as specified and as directed Returning Filling in including Spreading Levelling Watering and Well Ramming in Layers not exc. 250mm in SoftLoose Soil complete all as specified and as directed. 152 CUM 90
21 Removing excavated Materials Soils not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil complete all as specified and as directed Removing excavated Materials Soils not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil complete all as specified and as directed. 84 CUM 90
22 ML Sand Cushioning dry in Trenches for protection of UG Cables 230mm Spread thick ness and consolidated punned upto 180mm thickness complete all as specified and as directed ML Sand Cushioning dry in Trenches for protection of UG Cables below above and around the UG Cable laid in Trenches of 230mm Spread thick ness and consolidated punned upto 180mm thickness complete all as specified and as directed. NOTE For the purpose of Payment Punned thickness of Sand Cushioning only shall be Measured and Paid. 56 CUM 90
23 Supplying and laying unreinforced precast concrete cable coverClass HV Type I flat size 300 mm x 180mm x40mm complete all as specified and as directed Supplying and laying unreinforced precast concrete cable coverClass HV Type I flat size 300 mm x 180mm x40mm complete all as specified and as directed. 1699 Each 90
24 ML for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable complete all as specified and as directed ML for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable complete all as specified and as directed. 4 PER 1000 Nos 90
25 SF Galvanised Iron Pipe 100mm Bore dia Light Grade for protection of UG Cable laid in Floors Road Crossing fixing to Pole with Mild Steel Clamps SF Galvanised Iron Pipe 100mm Bore dia Light Grade for protection of UG Cable laid in Floors Road Crossing fixing to Pole with Mild Steel Clamps Nuts Bolts etc complete all as specified and as directed. 36 RM 90
26 SF Galvanised Iron Pipe 50mm Bore dia Light Grade for protection of UG Cable laid in Floors Road Crossing fixing to Pole with Mild Steel Clamps Nuts Bolts SF Galvanised Iron Pipe 50mm Bore dia Light Grade for protection of UG Cable laid in Floors Road Crossing fixing to Pole with Mild Steel Clamps Nuts Bolts etc. complete all as specified and as directed. 36 RM 90
27 Labour only for Horizontal Boring for Passing Protection Pipe up to 100mm Bore dia under Road Foot Path not exc. 10.00 mtr in a Single Length Labour only for Horizontal Boring for Passing Protection Pipe up to 100mm Bore dia under Road Foot Path not exc. 10.00 mtr in a Single Length complete all as specified and as directed. Note Pipe to be measured separately. 24 RM 90
28 S F 50 mm High density polyethylene pipe HDPE of pressure rating 6 kgfcm2 fixed complete to walls ceilings or in floors etc. complete all as specified and directed S F 50 mm High density polyethylene pipe HDPE of pressure rating 6 kgfcm2 fixed complete to walls ceilings or in floors etc. complete all as specified and directed . 18 RM 90
29 Supply and fixing garden light 10WLED IP65 rated inverted pyramid tripod type LED bolland with soft 360 degree light distribution complete all as specified Supply and fixing garden light 10WLED IP65 rated inverted pyramid tripod type LED bolland with soft 360 degree light distribution complete all as specified and directed.Make CromptonCat No.LBLSN10CDL 12 Each 90
30 SF Cable Junction Box 200X160X98mm in size made out of thermoplastic having IP 65 protection for outdoor installation fixed with 4 way bakelite cable SF Cable Junction Box 200X160X98mm in size made out of thermoplastic having IP 65 protection for outdoor installation fixed with 4 way bakelite cable terminals including 03 Nos polymide gland with check nut M32 02 No M25 01 No fixed on poles with Aluminium clamps of size 25x3mm nuts bolts washers etc. including taking out of old unserviceable cable junction box complete all as specified and as directed. Make Cat No. K8250 of HENSEL or equivalent model in SPELSBERGSintex. 12 Each 90
31 Supply commissioning and testing Outdoor type LT Distribution Panel Double door typeof size 1.2 1.2 0.450 m3.15 mm thick weather proof 3.15 Supply commissioning and testing Outdoor type LT Distribution Panel Double door typeof size 1.2 X 1.2 X0.450 m3.15 mm thick weather proof CPRI approved Seven tank treatment powder coated factory made LT Panel board totally enclosed dust and vermin proof openable from front back side canopy headedCable alley at both sides connected with suitable size MS angle iron frame for main distribution Panel fabricated with CRCA sheet 3.15mm thick sheet incluing IP 54 protection installed on concrete base made of PCC 136 type C1 using 20mm graded aggregate including self locking arragement. 1 Each 90

Similar tenders

India Public Procurement Intelligence

Frequently asked questions

The last date to submit a bid for Supply Laying Testing Cable Xlpe Insulated Screened Pvc Bedded Galvanized Steel Strip 11000 Volts G, Qty: 3311 is 30 Nov 2026. Submit before this date to be considered.

This tender has been issued by INDIAN ARMY in India.

The tender value is not disclosed; please refer to the tender document. EMD / bid security details are provided in the tender document.

This tender is Self Financed

The tender is classified under the following CPV code(s): 31300000 - Insulated wire and cable.

The tender notice and related documents are listed in the Documents section above. Select a document to view or download it. Please log in or register to access the documents. If you cannot find additional documents in the Documents section, please log in to your account and Send Document Request from your account section.

The TendersOnTime reference is 152770993. The purchaser document reference is available after login.

See the Similar Tenders section on this page or browse other tenders from India.

This tender falls under Technology and Equipment in India. Suppliers in these sectors can track similar India tenders using CPV-based alerts.