The INDIAN ARMY has issued a Tender notice for the procurement of a Supply Laying Testing Cable Xlpe Insulated Screened Pvc Bedded Galvanized Steel Strip 1100 Volts Gr, Qty: 1730 in the India.The project location is Bardhaman, West Bengal, India. This Tender notice was published on 20 Nov 2026 and is scheduled to close on 30 Nov 2026, with an estimated Tender value of Refer Document. Interested bidders can access detailed Tender information, eligibility criteria, and complete bidding documents by referencing TOT Ref No. 152770981 and Register on the platform.
Purchaser contact is for registered users
Login to see detailsTender details are for registered users
Login to see details| # | Title | Description | Qty | Unit | Delivery (Days) |
|---|---|---|---|---|---|
| 1 | Supply laying testing cable XLPE insulated screened PVC bedded galvanized steel strip 1100 volts grade of size 10 sq mm 4 core | Supply laying testing cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables heavy duty with stranded aluminium conductor 1100 volts grade of size 10 sq mm 4 core all as specified and as directed. | 60 | RM | 90 |
| 2 | Supply laying testing cable XLPE insulated screened PVC bedded galvanized steel strip 1100 volts grade of size 16 sq mm 4 core | Supply laying testing cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables heavy duty with stranded aluminium conductor 1100 volts grade of size 16 sq mm 4 core all as specified and as directed. | 150 | RM | 90 |
| 3 | Supply laying testing cable XLPE insulated screened PVC bedded galvanized steel strip 1100 volts grade of size 70 sq mm 3.5 core | Supply laying testing cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables heavy duty with stranded aluminium conductor 1100 volts grade of size 70 sq mm 3.5 core all as specified and as directed. | 800 | RM | 90 |
| 4 | Excavation in trenches not exceeding 1.5 m width and not exc 1.5m in depth getting out in softloose soil all as specified and as directed. | Excavation in trenches not exceeding 1.5 m width and not exc 1.5m in depth getting out in softloose soil all as specified and as directed. | 194 | CUM | 90 |
| 5 | Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in thick using excavated softloose soil all as specified and as directed. | Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in thick using excavated softloose soil all as specified and as directed. | 133 | CUM | 90 |
| 6 | Removal of surplus soil to a distance not exceeding 50 m and depositing where directed by Engrincharge. | Removal of surplus soil to a distance not exceeding 50 m and depositing where directed by Engrincharge. | 61 | CUM | 90 |
| 7 | ML Sand Cushioning dry in Trenches for protection of UG Cables below above and around the UG Cable laid in Trenches of 230mm Spread thickness | ML Sand Cushioning dry in Trenches for protection of UG Cables below above and around the UG Cable laid in Trenches of 230mm Spread thickness and consolidated punned upto 180mm thickness complete all as specified and as directed. Note For the purpose of Payment Punned thickness of Sand Cushioning only shall be Measured and Paid. | 61 | CUM | 90 |
| 8 | ML for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable | ML for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable complete all as specified and as directed. | 8 | Per 1000 Nos | 90 |
| 9 | ML for Double Wall Corrugated DWC High density polyethylene pipes HDPE of 40mm dia laid in trenches | ML for Double Wall Corrugated DWC High density polyethylene pipes HDPE of 40mm dia laid in trenches for cable protection complete all as spcified and directed. | 199 | RM | 90 |
| 10 | ML for fixing GI tubing 40mm dia light grade use for the protection of cable all as specified and directed by EngrinCharge. | ML for fixing GI tubing 40mm dia light grade use for the protection of cable all as specified and directed by EngrinCharge. | 30 | RM | 90 |
| 11 | ML for manual boring under road crossing and laying pipe across the road for laying cables complete all as specified and as directed. | ML for manual boring under road crossing and laying pipe across the road for laying cables complete all as specified and as directed. | 30 | RM | 90 |
| 12 | Supply commissioning and 0 Outdoor type LT Distribution Panel Double door RIP 54136 type C1 using 20mm | Supply commissioning and testing Outdoor type LT Distribution Panel Double door type weather proof CPRI approved Seven tank treatment powder coated factory made LT Panel board totally enclosed dust and vermin proof openable from front back side canopy headedCable alley at both sides connected with suitable size MS angle iron frame for main distribution Panel fabricated with CRCA sheet 3.15mm thick sheet incluing IP 54 protection installed on concrete base made of PCC 136 type C1 using 20mm graded aggregate including self locking arragement including taking down old unserviceable one. | 1 | Each | 90 |
| 13 | ML for earthing complete with MS galvanized plate of size 60cmx60cmx6mm as earth electrode buried directly in ground earth pit not less than 2.25 mtrs | ML for earthing complete with MS galvanized plate of size 60cmx60cmx6mm as earth electrode buried directly in ground earth pit not less than 2.25 mtrs deep below ground level with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanised iron strip 25x4mm as earthing lead by means of bolts nuts check nuts and washers of galvanised ironwelding or steel all as shown in electrical plate No 3 in SSR Part I of 2009 connected to earthing test point all as specified complete with excavation earth work PCC pit with 50mm thick RCC coverCI MS cover having suitable handle 10mm MS Rod 20mm dia GI medium grade watering pipe with GI funnel with wire mesh 40mm bore GI pipe medium grade ISI marked for protection of earth lead conductor and testing on completion complete all as specified and as directed by EngineerinCharge. | 2 | Each set | 90 |
| Tender | State | TOT Ref. No. | Bid deadline |
|---|---|---|---|
| Supply and Commissioning of 2.8 Kva Petrol Start, Petrol Run Portable Generators as Per Speci Fication Attached. Make- as Per Specification. [ Warranty Period: 30 Months after the Date of Delivery ] ] | Chhattisgarh | 152909607 | 28 Dec 2026 |
| Shim for Elastic Ring for 3P Locos Size: | Gujarat | 152909606 | 26 Dec 2026 |
| Set of Spare for Pneumatic Horn as Per Clw Drg. No. 0/2/65/109 | Gujarat | 152909605 | 26 Dec 2026 |
| Locking Bracket for Bpfl Switches Make Tekmec and Hotline | Gujarat | 152909604 | 26 Dec 2026 |
| Rubber Gasket Round for Epc Air Pipeline | Gujarat | 152909603 | 26 Dec 2026 |