Open for bids Tender India NCB TOT Ref. 153066886

SITC of VRF AC, Multiple Split System Air Tender - 153066886

Tender notice from India, published on 26 Nov 2026.

Executive Summary

The ODISHA UNIVERSITY OF TECHNOLOGY AND RESEARCH has issued a Tender notice for the procurement of a SITC of VRF AC, Multiple Split System Air Conditioners and Air to Air Heat Pumps (VRF Air Conditioners) Conforming t..., Qty: 8743 in the India.The project location is -, Odisha, India. This Tender notice was published on 26 Nov 2026 and is scheduled to close on 19 Dec 2026, with an estimated Tender value of Refer Document. Interested bidders can access detailed Tender information, eligibility criteria, and complete bidding documents by referencing TOT Ref No. 153066886 and Register on the platform.

Key facts

Summary
SITC of VRF AC, Multiple Split System Air Conditioners and Air to Air Heat Pumps (VRF Air Conditioners) Conforming t..., Qty: 8743
TOT Ref. No.
153066886
Document Ref. No.
Login to see
City
-
State
Odisha
Notice type
Tender
Competition
NCB
Publication date
26 Nov 2026
Bid deadline
19 Dec 2026
EMD
720000
Tender value
Refer Document
Purchaser ownership
Public
Procurement Type
Goods
Financier
Self Financed

CPV classification

Purchaser details

Purchaser contact is for registered users

Login to see details

Tender details

Tender details are for registered users

Login to see details

Documents

Tender Notice
Login to view
Bid_Document_10132886.pdf
Login to view
Specification_Document.pdf
Login to view
BOQ_Document.csv
Login to view

Bill of Quantities (BOQ)

# Title Description Qty Unit Delivery (Days)
1 VRF Outdoor Unit 96 HP Supply Supply of variable refrigerant flow air conditioning system modular outdoor unit top discharge 96 HP nominal capacity 32 HP x 3 nos. Compact air cooled type scroll compressor with heating and cooling only technology 100 percent inverter compressors VEER technology Golden Fins anti corrosive treatment operating ambient temp minus 15 deg C to 55 deg C auto dust removal IP55 fan motor protection. 4 Set 60
2 VRF Outdoor Unit 64 HP Supply Supply of variable refrigerant flow air conditioning system modular outdoor unit top discharge 64 HP nominal capacity 32 HP x 2 nos. Compact air cooled type scroll compressor with heating and cooling only technology 100 percent inverter compressors VEER technology Golden Fins anti corrosive treatment operating ambient temp minus 15 deg C to 55 deg C auto dust removal IP55 fan motor protection. 2 Set 60
3 VRF Outdoor Unit 32 HP Supply Supply of variable refrigerant flow air conditioning system modular outdoor unit top discharge 32 HP nominal capacity. Compact air cooled type scroll compressor with heating and cooling only technology 100 percent inverter compressors VEER technology Golden Fins anti corrosive treatment operating ambient temp minus 15 deg C to 55 deg C auto dust removal IP55 fan motor protection. 1 Set 60
4 VRF Indoor Unit 1.5 TR Four Way Cassette Supply Supply of variable refrigerant flow modular type indoor units four way cassette type 1.5 TR nominal capacity wired wireless remote suitable for R410a refrigerant 230 plus minus 5 percent V 50Hz 1 phase AC power supply complete with pre filter and remote as per requirement. 212 Nos 60
5 VRF Indoor Unit 2.5 TR Four Way Cassette Supply Supply of variable refrigerant flow modular type indoor units four way cassette type 2.5 TR nominal capacity wired wireless remote suitable for R410a refrigerant 230 plus minus 5 percent V 50Hz 1 phase AC power supply complete with pre filter and remote as per requirement. 10 Nos 60
6 VRF Indoor Unit 3.2 TR Four Way Cassette Supply Supply of variable refrigerant flow modular type indoor units four way cassette type 3.2 TR nominal capacity wired wireless remote suitable for R410a refrigerant 230 plus minus 5 percent V 50Hz 1 phase AC power supply complete with pre filter and remote as per requirement. 20 Nos 60
7 VRF Indoor Unit 4.0 TR Four Way Cassette Supply Supply of variable refrigerant flow modular type indoor units four way cassette type 4.0 TR nominal capacity wired wireless remote suitable for R410a refrigerant 230 plus minus 5 percent V 50Hz 1 phase AC power supply complete with pre filter and remote as per requirement. 16 Nos 60
8 Refnet Joints for Indoor Refrigerant Piping Supply Supply of Y joints Refnets for Indoor refrigerant piping connection to be provided in refrigerant pipe line complete with accessories. 251 Nos 60
9 Refnet Joints for 3 Outdoor Refrigerant Piping Supply Supply of Y joints Refnets for 3 Outdoor refrigerant piping connection to be provided in refrigerant pipe line complete with accessories. 3 Set 60
10 Refnet Joints for 2 Outdoor Refrigerant Piping Supply Supply of Y joints Refnets for 2 Outdoor refrigerant piping connection to be provided in refrigerant pipe line complete with accessories. 2 Set 60
11 Installation and Commissioning of VRF ODU 96 HP Installation and Commissioning of Inverter VRF Units with outdoor mounting pressure testing nitrogen flushing etc of VRF ODU for 96 HP nominal capacity of modular outdoor units top discharge 32 HP x 3 nos. 4 Set 60
12 Installation and Commissioning of VRF ODU 64 HP Installation and Commissioning of Inverter VRF Units with outdoor mounting pressure testing nitrogen flushing etc of VRF ODU for 64 HP nominal capacity of modular outdoor units top discharge 32 HP x 2 nos. 2 Set 60
13 Installation and Commissioning of VRF ODU 32 HP Installation and Commissioning of Inverter VRF Units with outdoor mounting pressure testing nitrogen flushing etc of VRF ODU for 32 HP nominal capacity of modular outdoor units top discharge. 1 Set 60
14 Installation and Commissioning of VRF IDU 1.5 TR Cassette Installation testing and commissioning of Four Way Cassette Type Indoor Units 1.5 TR nominal capacity complete with accessories and supports. 212 Nos 60
15 Installation and Commissioning of VRF IDU 2.5 TR Cassette Installation testing and commissioning of Four Way Cassette Type Indoor Units 2.5 TR nominal capacity complete with accessories and supports. 10 Nos 60
16 Installation and Commissioning of VRF IDU 3.2 TR Cassette Installation testing and commissioning of Four Way Cassette Type Indoor Units 3.2 TR nominal capacity complete with accessories and supports. 20 Nos 60
17 Installation and Commissioning of VRF IDU 4.0 TR Cassette Installation testing and commissioning of Four Way Cassette Type Indoor Units 4.0 TR nominal capacity complete with accessories and supports. 16 Nos 60
18 Installation of Refnet Joints Indoor Installation of Y joints Refnets for Indoor refrigerant piping connection to be provided in refrigerant pipe line. 251 Nos 60
19 Installation of Refnet Joints 3 Outdoor Installation of Y joints Refnets for 3 Outdoor refrigerant piping connection to be provided in refrigerant pipe line. 3 Set 60
20 Installation of Refnet Joints 2 Outdoor Installation of Y joints Refnets for 2 Outdoor refrigerant piping connection in refrigerant pipe line. 2 Set 60
21 SITC Copper Piping Soft Drawn 6.4 mm OD Supply installation testing and commissioning including vacuumisation and nitrogen testing of soft drawn copper refrigerant piping 6.4 mm diameter OD with tube thickness of 1.2 mm with 19 mm thick insulation complete with fittings and supports measured per running meter. 220 meter 60
22 SITC Copper Piping Soft Drawn 9.5 mm OD Supply installation testing and commissioning including vacuumisation and nitrogen testing of soft drawn copper refrigerant piping 9.5 mm diameter OD with tube thickness of 1.2 mm with 19 mm thick insulation complete with fittings and supports measured per running meter. 750 meter 60
23 SITC Copper Piping Soft Drawn 12.7 mm OD Supply installation testing and commissioning including vacuumisation and nitrogen testing of soft drawn copper refrigerant piping 12.7 mm diameter OD with tube thickness of 1.2 mm with 19 mm thick insulation complete with fittings and supports measured per running meter. 280 meter 60
24 SITC Copper Piping Soft Drawn 15.86 mm OD Supply installation testing and commissioning including vacuumisation and nitrogen testing of soft drawn copper refrigerant piping 15.86 mm diameter OD with tube thickness of 1.2 mm with 19 mm thick insulation complete with fittings and supports measured per running meter. 750 meter 60
25 SITC Copper Piping Hard Drawn 19 mm OD Supply installation testing and commissioning including vacuumisation and nitrogen testing of hard drawn copper refrigerant piping 19 mm diameter OD with tube thickness of 1.2 mm with 19 mm thick insulation complete with fittings and supports measured per running meter. 600 meter 60
26 SITC Copper Piping Hard Drawn 22.2 mm OD Supply installation testing and commissioning including vacuumisation and nitrogen testing of hard drawn copper refrigerant piping 22.2 mm diameter OD with tube thickness of 1.2 mm with 19 mm thick insulation complete with fittings and supports measured per running meter. 70 meter 60
27 SITC Copper Piping Hard Drawn 25.4 mm OD Supply installation testing and commissioning including vacuumisation and nitrogen testing of hard drawn copper refrigerant piping 25.4 mm diameter OD with tube thickness of 1.2 mm with 19 mm thick insulation complete with fittings and supports measured per running meter. 35 meter 60
28 SITC Copper Piping Hard Drawn 28.58 mm OD Supply installation testing and commissioning including vacuumisation and nitrogen testing of hard drawn copper refrigerant piping 28.58 mm diameter OD with tube thickness of 1.2 mm with 19 mm thick insulation complete with fittings and supports measured per running meter. 150 meter 60
29 SITC Copper Piping Hard Drawn 31.8 mm OD Supply installation testing and commissioning including vacuumisation and nitrogen testing of hard drawn copper refrigerant piping 31.8 mm diameter OD with tube thickness of 1.2 mm with 19 mm thick insulation complete with fittings and supports measured per running meter. 40 meter 60
30 SITC Copper Piping Hard Drawn 34.9 mm OD Supply installation testing and commissioning including vacuumisation and nitrogen testing of hard drawn copper refrigerant piping 34.9 mm diameter OD with tube thickness of 1.2 mm with 19 mm thick insulation complete with fittings and supports measured per running meter. 50 meter 60
31 SITC Copper Piping Hard Drawn 38.1 mm OD Supply installation testing and commissioning including vacuumisation and nitrogen testing of hard drawn copper refrigerant piping 38.1 mm diameter OD with tube thickness of 1.2 mm with 19 mm thick insulation complete with fittings and supports measured per running meter. 200 meter 60
32 SITC Copper Piping Hard Drawn 41.27 mm OD Supply installation testing and commissioning including vacuumisation and nitrogen testing of hard drawn copper refrigerant piping 41.27 mm diameter OD with tube thickness of 1.2 mm with 19 mm thick insulation complete with fittings and supports measured per running meter. 40 meter 60
33 SITC Copper Piping Hard Drawn 44 mm OD Supply installation testing and commissioning including vacuumisation and nitrogen testing of hard drawn copper refrigerant piping 44 mm diameter OD with tube thickness of 1.2 mm with 19 mm thick insulation complete with fittings and supports measured per running meter. 90 meter 60
34 Rigid PVC Drain Piping 25mm dia Supply and installation testing and commissioning of Rigid heavy class PVC piping complete with fittings supports and insulated with 6mm thick nitrile rubber insulation up to outer edge of wall 25mm dia measured per running meter. 670 meter 60
35 Rigid PVC Drain Piping 32mm dia Supply and installation testing and commissioning of Rigid heavy class PVC piping complete with fittings supports and insulated with 6mm thick nitrile rubber insulation up to outer edge of wall 32mm dia measured per running meter. 515 meter 60
36 Rigid PVC Drain Piping 40mm dia Supply and installation testing and commissioning of Rigid heavy class PVC piping complete with fittings supports and insulated with 6mm thick nitrile rubber insulation up to outer edge of wall 40mm dia measured per running meter. 335 meter 60
37 Rigid PVC Drain Piping 50mm dia Supply and installation testing and commissioning of Rigid heavy class PVC piping complete with fittings supports and insulated with 6mm thick nitrile rubber insulation up to outer edge of wall 50mm dia measured per running meter. 120 meter 60
38 Control Cable 2C x 0.75 Sqmm Shielded Supply and laying of 2C x 0.75 Sqmm shielded copper control cum communication transmission cable to be laid in suitable sizes of conduit between indoor units and outdoor units measured per running meter. 2456 meter 60
39 GI Perforated Cable Tray Supply installation testing and commissioning of GI perforated cable tray for exposed copper piping complete with supports and accessories measured per running meter. 105 meter 60

Similar tenders

India Public Procurement Intelligence

Frequently asked questions

The last date to submit a bid for SITC of VRF AC, Multiple Split System Air Conditioners and Air to Air Heat Pumps (VRF Air Conditioners) Conforming t..., Qty: 8743 is 19 Dec 2026. Submit before this date to be considered.

This tender has been issued by ODISHA UNIVERSITY OF TECHNOLOGY AND RESEARCH in India.

The tender value is not disclosed; please refer to the tender document. The EMD / bid security is ₹720000.

This tender is Self Financed

This is a Goods procurement tender issued as a public sector opportunity in India.

The tender is classified under the following CPV code(s): 39717000 - Fans and air-conditioning appliances, 42512500 - Parts of air-conditioning machines, 39717200 - Air-conditioning appliances.

The tender notice and related documents are listed in the Documents section above. Select a document to view or download it. Please log in or register to access the documents. If you cannot find additional documents in the Documents section, please log in to your account and Send Document Request from your account section.

The TendersOnTime reference is 153066886. The purchaser document reference is available after login.

See the Similar Tenders section on this page or browse other tenders from India.

This tender falls under Technology and Equipment in India. Suppliers in these sectors can track similar India tenders using CPV-based alerts.