Cross Icon
Cross Icon

SITC OF HIWALL SPLIT AC AT LHO KOLKATA, Split Air Tender - 150897592

STATE BANK OF INDIA (SBI) has floated a tender for SITC OF HIWALL SPLIT AC AT LHO KOLKATA, Split Air Conditioner, Wall Mount Type (V3) ISI Marked to IS 1391 (Part 2), Qty: 52. The project location is Nadia, West Bengal, India. The reference number is - and it is closing on 23 Oct 2026. Suppliers can request Register free of cost to get the complete Tender details and download the document.

Procurement Summary

State: West Bengal

Summary: SITC OF HIWALL SPLIT AC AT LHO KOLKATA, Split Air Conditioner, Wall Mount Type (V3) ISI Marked to IS 1391 (Part 2), Qty: 52

Deadline: 23 Oct 2026

Posting Date: 14 Oct 2026

Other Information

Notice Type: Tender

TOT Ref.No.: 150897592

Document Ref. No.: Login to see detail

Financier: Self Financed

Purchaser Ownership: Public

Document Fees: Refer Document

Tender Value: ₹ 261941

EMD: Refer Document

Purchaser's Detail

Name: Login to see details

Address: Login to see details

Email: Login to see details

  Login to see details

Documents

 Tender Notice

Bid_Document_10030713.pdf

Specification_Document.pdf

BOQ_Document.csv

Bill of Quantities (BOQ)

# Title Description Qty Unit Delivery (Days)
1 SITC OF 1.5 TR HI-WALL SPLIT SYSTEMS Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete withIndoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr(IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) R-32/R-410/ R-407 Green Refrigerant <br>wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotarycompressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply Electrical cable IS 694 or IS 9968 temperature sensing control IS/International Electrotechnical Commission (IEC) 60730,hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS - 1391 Part II 2023. The system shall be able to operate up to 50 Degree C (out door ambient temperature). Inverter Type Cooling with 5 Star BEE Rating, Minimum value of ISEER 5.6. 2 SET 15
2 SITC OF 2.0 TR HI-WALL SPLIT SYSTEMS Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete withIndoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr(IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) R-32/R-410/ R-407 Green Refrigerant <br>wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotarycompressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply Electrical cable IS 694 or IS 9968 temperature sensing control IS/International Electrotechnical Commission (IEC) 60730,hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS - 1391 Part II 2023. The system shall be able to operate up to 50 Degree C (out door ambient temperature). Inverter Type Cooling with 5 Star BEE Rating, Minimum value of ISEER 5.6. 2 SET 15
3 COPPER REFRIGERANT PIPING FOR 1.5TR AND 2.0TR HI-WALL SPLIT AC Supplying, Installation, testing and commissioning including Power cable ,vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for above system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessoriesas per specifications etc. as required 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm and 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm for 1.5 TR HI WALL SPLIT 20 Mtr 15
4 DRAIN PIPE Supply and fixing of duly insulated 25mm UPVC drain pipe 20 Mtr 15
5 OUTDOOR STAND FOR 1.5TR AND 2.0TR HI-WALL SPLIT AC Supplying , Installation, Testing and Commissioning of outdoor frame / stands to withstand the full load of outdoor units and making good all the damage for 1.5 TR Hi-Wall Split AC. 4 SET 15
6 DISMANTLING OF OLD AC SYSTEMS Dismantling of existing air conditioner 4 SET 15

Corresponding Contract Award Notice

No Contract Award Notice found for this tender. Please try using the Contract Award Search Page.


Request Demo
GiZ Tenders India