Cross Icon
Cross Icon

SITC of Air Conditioner System at SBI MINI RACPC Tender - 150821215

STATE BANK OF INDIA (SBI) has floated a tender for SITC of Air Conditioner System at SBI MINI RACPC KRISHNANAGAR, Qty: 185. The project location is Nadia, West Bengal, India. The reference number is - and it is closing on 22 Oct 2026. Suppliers can request Register free of cost to get the complete Tender details and download the document.

Procurement Summary

State: West Bengal

Summary: SITC of Air Conditioner System at SBI MINI RACPC KRISHNANAGAR, Qty: 185

Deadline: 22 Oct 2026

Posting Date: 13 Oct 2026

Other Information

Notice Type: Tender

TOT Ref.No.: 150821215

Document Ref. No.: Login to see detail

Financier: Self Financed

Purchaser Ownership: Public

Document Fees: Refer Document

Tender Value: ₹ 1090202

EMD: ₹ 9500

Purchaser's Detail

Name: Login to see details

Address: Login to see details

Email: Login to see details

  Login to see details

Documents

 Tender Notice

Bid_Document_10021700.pdf

Specification_Document.pdf

BOQ_Document.csv


Corresponding Contract Award Notice

No Contract Award Notice found for this tender. Please try using the Contract Award Search Page.

Bill of Quantities (BOQ)

# Title Description Qty Unit Delivery (Days)
1 SITC OF 1.5 TR HI-WALL SPLIT SYSTEMS Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete withIndoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr(IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant <br>wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotarycompressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply Electrical cable IS 694 or IS 9968 temperature sensing control IS/International Electrotechnical Commission (IEC) 60730,hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS - 1391 Part II 2023. The system shall be able to operate up to 50 Degree C (out door ambient temperature). Inverter Type Cooling with 5 Star BEE Rating, Minimum value of ISEER 5.6 1 SET 15
2 SITC OF 2.0 TR HI-WALL SPLIT SYSTEMS Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete withIndoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr(IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant <br>wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotarycompressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply Electrical cable IS 694 or IS 9968 temperature sensing control IS/International Electrotechnical Commission (IEC) 60730,hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS - 1391 Part II 2023. The system shall be able to operate up to 50 Degree C (out door ambient temperature). Inverter Type Cooling with 5 Star BEE Rating, Minimum value of ISEER 5.6 3 SET 15
3 SITC OF 2.0TR CASSETTE TYPE SPLIT SYSTEMS Supplying, Installation, Testing and Commissioning of Air Cooled Cassette type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), R-32/R410A/R-407 Green Refrigerant, wireless Remote, inbuilt drain pump, suitable for 400/230V, 50 Hz ,1 /3 phase AC supply, including surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 5.5 Mtr (IDU to ODU), copper power and <br>control cable upto 5.5 Mtr (IDU to ODU) including drain pipe, the system shall be capable of performing cooling,dehumidification, Air circulation, filteration & ventilation of following capacity with Scroll/rotary compressor with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB) as specified. The system shall be able to deliver 100% of the rated capacity as per relevant IS Code. The lab testing reports as per IS -1391 shall be submitted from National Accreditation Board for Testing and Calibration Laboratories (NABL) accredited as per International Electrotechnical Commission (IEC) 17025 standards/Central Power Research Institute (CPRI)/ Electrical Research and Development Association (ERDA)with Original Equipment Manufacturer (OEM) etc. complete as per CPWD specification and as per IS 1391 as required. Inverter Type Cooling with 5 Star BEE Rating , Minimum value of ISEER 5.6 1 SET 15
4 SITC OF 3.0TR CASSETTE TYPE SPLIT SYSTEMS Supplying, Installation, Testing and Commissioning of Air Cooled Cassette type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), R-32/R410A/R-407 Green Refrigerant, wireless Remote, inbuilt drain pump, suitable for 400/230V, 50 Hz ,1 /3 phase AC supply, including surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 5.5 Mtr (IDU to ODU), copper power and <br>control cable upto 5.5 Mtr (IDU to ODU) including drain pipe, the system shall be capable of performing cooling,dehumidification, Air circulation, filteration & ventilation of following capacity with Scroll/rotary compressor with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB) as specified. The system shall be able to deliver 100% of the rated capacity as per relevant IS Code. The lab testing reports as per IS -1391 shall be submitted from National Accreditation Board for Testing and Calibration Laboratories (NABL) accredited as per International Electrotechnical Commission (IEC) 17025 standards/Central Power Research Institute (CPRI)/ Electrical Research and Development Association (ERDA)with Original Equipment Manufacturer (OEM) etc. complete as per CPWD specification and as per IS 1391 as required. Inverter Type Cooling with 5 Star BEE Rating , Minimum value of ISEER 5.6 5 SET 15
5 COPPER REFRIGERANT PIPING for 1.5TR,2.0TR HI-WALL SPLIT AC AND 2.0TR CASSETTE AC Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for above system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, along with electrical flexible copper 4core cable & all accessoriesas per specifications etc. as required 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm and 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm for 1.5TR,2.0TR SPLIT AC AND 2.0 TR CASSETTE AC 30 Mtr 15
6 COPPER REFRIGERANT PIPING for 3.0TR CASSETTE TYPE SPLIT UNITS Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for above system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines,along with electrical flexible copper 4core with all accessoriesas per specifications etc. as required 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm for 2.0 and 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm for 3.0 TR CASSETTE TYPE SPLIT UNITS 50 Mtr 15
7 DRAIN PIPE Supply and fixing of duly insulated 25mm UPVC drain pipe 80 Mtr 15
8 OUTDOOR STAND for 1.0TR,2.0TR HI-WALL SPLIT AC AND 2.0TR CASSETTE Supplying , Installation, Testing and Commissioning of outdoor frame / stands to withstand the full load of outdoor units and making good all the damage for 1.5 TR Hi-Wall Split AC. 5 SET 15
9 OUTDOOR STAND for 3.0TR CASSETTE TYPE SPLIT UNITS Supplying , Installation, Testing and Commissioning of outdoor frame / stands to withstand the full load of outdoor units and making good all the damage for 2.0 TR CASSETTE TYPE SPLIT UNITS. 5 SET 15
10 VOLTAGE STABILIZER FOR 1.5 TR SPLIT SYSTEMS Supplying, Installation, testing and commissioning of stabliser with Rated 4KVA,Input voltage range 130-260 voltage ,Output voltgae range 195-245 voltage ,metalic encloser,100% copper winding,wall mounting type,digital type voltmeter,class B type insulation temperature and furnish all test report and certificate.The product with minimum 2 yrs of warranty,Automatic Line Voltage Correctors <br>(Step Type) as per IS-8448 1989 1 SET 15
11 VOLTAGE STABILIZER FOR 2.0 TR SPLIT AND 2.0TR,3.0TR CASSETTE SYSTEMS Supplying, Installation, testing and commissioning of stabliser with Rated 5KVA,Input voltage range 130-260 voltage ,Output voltgae range 195-245 voltage ,metalic encloser,100% copper winding,wall mounting type,digital type voltmeter,class B type insulation temperature and furnish all test report and certificate.The product with minimum 2 yrs of warranty,Automatic Line Voltage Correctors <br>(Step Type) as per IS-8448 1989 4 SET 15

Request Demo
GiZ Tenders India