Login
Register
Complete Your Profile
Change Password
Request a Password Reset
Download Documents
Download Documents
Get Help to Participate in This Tender
Our team will contact you shortly.
Your activation form is pending.
Please submit it to start receiving email alerts.
Submit NowChange Password
For better security, update the account password.
BHARAT PETROLEUM CORPORATION LIMITED (BPCL) has floated a tender for PROCUREMENT OF PIPE FITTINGS AND FLANGES, Qty: 4157. The project location is Mumbai, Maharashtra, India. The reference number is - and it is closing on 29 Oct 2026. Suppliers can request Register free of cost to get the complete Tender details and download the document.
Procurement Summary
State: Maharashtra
Summary: PROCUREMENT OF PIPE FITTINGS AND FLANGES, Qty: 4157
Deadline: 29 Oct 2026
Posting Date: 15 Oct 2026
Other Information
Notice Type: Tender
TOT Ref.No.: 150996145
Document Ref. No.: Login to see detail
Financier: Self Financed
Purchaser Ownership: Public
Document Fees: Refer Document
Tender Value: Refer Document
EMD: Refer Document
Purchaser's Detail
Name: Login to see details
Address: Login to see details
Email: Login to see details
Login to see detailsDocuments
| # | Title | Description | Qty | Unit | Delivery (Days) |
|---|---|---|---|---|---|
| 1 | TEE EQ BW CS WPB S40 200NB | As per RFQ | 35 | PC | 15 |
| 2 | ELB BW CS WPB 90DEG LR S40 200NB | As per RFQ | 50 | PC | 15 |
| 3 | FLG SO CS A105 RF 300 25NB | As per RFQ | 50 | PC | 15 |
| 4 | CPLG SW FULL CS A105 3000 25NB | As per RFQ | 50 | PC | 15 |
| 5 | ELB BW CS WPB 90DEG LR S20 300NB | As per RFQ | 40 | PC | 15 |
| 6 | FLG SO CS A105 RF 150 300NB | As per RFQ | 40 | PC | 15 |
| 7 | FLG SO CS A105 RF 150 400NB | As per RFQ | 100 | PC | 15 |
| 8 | ELB BW CS WPB 90DEG LR IBR S80 100NB | As per RFQ | 120 | PC | 15 |
| 9 | ELB SW CS A105 90DEG 3000 IBR 20NB | As per RFQ | 120 | PC | 15 |
| 10 | ELB SW CS A105 90DEG 3000 25NB | As per RFQ | 35 | PC | 15 |
| 11 | RED CON BW CS WPB S80 80 100X50NB | As per RFQ | 10 | PC | 15 |
| 12 | TEE EQ BW CS WPB S40 100NB | As per RFQ | 15 | PC | 15 |
| 13 | TEE EQ BW CS WPB S40 150NB | As per RFQ | 20 | PC | 15 |
| 14 | TEE EQ BW CS WPB 5.49MM 80NB | As per RFQ | 10 | PC | 15 |
| 15 | TEE RED BW CS WPB IBR S40 150X100NB | As per RFQ | 10 | PC | 15 |
| 16 | FLG BLIND CS A105 RF 150 15NB | As per RFQ | 30 | PC | 15 |
| 17 | FLG BLIND CS A105 RF 150 20NB | As per RFQ | 510 | PC | 15 |
| 18 | FLG BLIND CS A105 RF 150 IBR 20NB | As per RFQ | 100 | PC | 15 |
| 19 | FLG WN CS A105 600 S80 IBR 100NB | As per RFQ | 100 | EA | 15 |
| 20 | FLG WN CS A105 600 IBR S80 150NB | As per RFQ | 50 | PC | 15 |
| 21 | ELB BW CS WPB 90DEG LR NACE STD 200NB | As per RFQ | 10 | PC | 15 |
| 22 | FLG BLIND CS A105 RF 150 200NB | As per RFQ | 10 | PC | 15 |
| 23 | FLG BLIND CS A105 RF 600 200NB | As per RFQ | 5 | PC | 15 |
| 24 | FLG WN CS A105 600 S80 200NB | As per RFQ | 10 | PC | 15 |
| 25 | TEE RED SW CS A105 3000 20X15NB | As per RFQ | 30 | PC | 15 |
| 26 | TEE RED SW CS A105 3000 25X20NB | As per RFQ | 30 | PC | 15 |
| 27 | TEE RED SW CS A105 3000 25X15NB | As per RFQ | 30 | PC | 15 |
| 28 | TEE EQ SW CS A105 3000 15NB | As per RFQ | 50 | PC | 15 |
| 29 | CPLG SW REDUCER CS A105 3000 25X15NB | As per RFQ | 30 | PC | 15 |
| 30 | CPLG SW REDUCER CS A105 3000 40X25NB | As per RFQ | 30 | PC | 15 |
| 31 | CPLG SW REDUCER CS A105 3000 40X20NB | As per RFQ | 30 | PC | 15 |
| 32 | CPLG SW REDUCER CS A105 3000 40X15NB | As per RFQ | 30 | PC | 15 |
| 33 | CPLG SW FULL CS A105 3000 IBR 25NB | As per RFQ | 50 | PC | 15 |
| 34 | RED CON BW CS WPB S40 40 50X40NB | As per RFQ | 10 | EA | 15 |
| 35 | RED CON BW CS WPB THK 6.4 100X80NB | As per RFQ | 10 | PC | 15 |
| 36 | RED CON BW CS WPB S40 40 200X150NB | As per RFQ | 10 | PC | 15 |
| 37 | RED CON BW CS WPB S40 40 100X50NB | As per RFQ | 20 | PC | 15 |
| 38 | RED CON BW CS WPB S40 80 50X25NB | As per RFQ | 30 | PC | 15 |
| 39 | ELB SW CS A105 90DEG 6000 IBR 15NB | As per RFQ | 200 | PC | 15 |
| 40 | ELB SW CS A105 90DEG 3000 IBR 15NB | As per RFQ | 200 | PC | 15 |
| 41 | TEE EQ BW CS WPB IBR STD 200NB | As per RFQ | 30 | PC | 15 |
| 42 | TEE EQ BW CS WPB IBR STD 250NB | As per RFQ | 30 | PC | 15 |
| 43 | FLG SO CS A105 FF 150 400NB | As per RFQ | 200 | PC | 15 |
| 44 | FLG SO CS A105 FF 150 500NB | As per RFQ | 160 | PC | 15 |
| 45 | ELB BW CS WPB 90DEG LR S20 500NB | As per RFQ | 30 | PC | 15 |
| 46 | ELB BW CS WPB-W 45DEG LR STD 500NB | As per RFQ | 6 | PC | 15 |
| 47 | ELB BW CS WPB-W 90DEG LR STD 500NB | As per RFQ | 12 | PC | 15 |
| 48 | ELB BW CS WPB 90DEG LR S80 50NB | As per RFQ | 50 | PC | 15 |
| 49 | ELB BW CS WPB 90DEG LR IBR S80 50NB | As per RFQ | 50 | PC | 15 |
| 50 | ELB BW CS WPB 45DEG LR S80 50NB | As per RFQ | 10 | PC | 15 |
| 51 | ELB BW CS WPB 45DEG LR IBR S80 50NB | As per RFQ | 10 | PC | 15 |
| 52 | FLG SW CS A105 RF 300 40NB | As per RFQ | 20 | PC | 15 |
| 53 | FLG WN CS A105 150 XS 50NB | As per RFQ | 50 | EA | 15 |
| 54 | FLG SO CS A105 RF 150 50NB | As per RFQ | 100 | PC | 15 |
| 55 | FLG WN CS A105 150 IBR XS 50NB | As per RFQ | 60 | PC | 15 |
| 56 | FLG WN CS A105 300 IBR S80 50NB | As per RFQ | 60 | PC | 15 |
| 57 | FLG WN CS A105 300 IBR S40 80NB | As per RFQ | 60 | PC | 15 |
| 58 | FLG WN CS A105 150 IBR S40 80NB | As per RFQ | 60 | PC | 15 |
| 59 | ELB BW CS WPB 90DEG LR IBR S40 150NB | As per RFQ | 80 | PC | 15 |
| 60 | ELB BW CS WPB 90DEG LR IBR XS 150NB | As per RFQ | 80 | PC | 15 |
| 61 | FLG WN CS A105 300 XS 40NB | As per RFQ | 10 | PC | 15 |
| 62 | FLG WN CS A105 150 S80 40NB | As per RFQ | 10 | EA | 15 |
| 63 | ELB BW CS WPB 45DEG LR H2 STD 150NB | As per RFQ | 10 | PC | 15 |
| 64 | ELB BW CS WPB 90DEG LR NACE STD 100NB | As per RFQ | 20 | PC | 15 |
| 65 | ELB BW CS WPB 45DEG LR S160 50NB | As per RFQ | 20 | PC | 15 |
| 66 | ELB BW CS WPB 45DEG LR NACE XS 100NB | As per RFQ | 15 | PC | 15 |
| 67 | ELB BW CS WPB 45DEG LR S160 80NB | As per RFQ | 15 | PC | 15 |
| 68 | ELB BW CS WPB 90DEG LR S160 80NB | As per RFQ | 25 | PC | 15 |
| 69 | FLG WN CS A105 300 S80 40NB | As per RFQ | 10 | PC | 15 |
| 70 | ELB BW CS WPB 45DEG LR S40 100NB | As per RFQ | 12 | PC | 15 |
| 71 | RED CON BW CS WPB S40 40 150X100NB | As per RFQ | 20 | PC | 15 |
| 72 | TEE EQ BW CS WPB STD 100NB | As per RFQ | 10 | EA | 15 |
| 73 | ELB BW CS WPB 90DEG LR S160 50NB | As per RFQ | 30 | PC | 15 |
| 74 | ELB BW CS WPB 45DEG LR NACE XS 150NB | As per RFQ | 10 | PC | 15 |
| 75 | ELB BW CS WPB 90DEG LR NACE XS 150NB | As per RFQ | 20 | PC | 15 |
| 76 | ELB SW CS A105 90DEG 3000 IBR 40NB | As per RFQ | 50 | PC | 15 |
| 77 | ELB SW CS A105 45DEG 3000 IBR 40NB | As per RFQ | 50 | PC | 15 |
| 78 | FLG WN CS A105 150 NACE STD 100NB | As per RFQ | 20 | PC | 15 |
| 79 | FLG WN CS A105 150 NACE STD 150NB | As per RFQ | 26 | EA | 15 |
| 80 | FLG BLIND CS A105 RF 150 50NB | As per RFQ | 10 | PC | 15 |
| 81 | FLG BLIND CS A105 RF 150 100NB | As per RFQ | 4 | PC | 15 |
| 82 | FLG BLIND CS A105 RF 150 150NB | As per RFQ | 10 | PC | 15 |
| 83 | FLG WN CS A105 300 NACE S160 50NB | As per RFQ | 20 | PC | 15 |
| 84 | FLG WN CS A105 150 S80 IBR 50NB | As per RFQ | 20 | EA | 15 |
| 85 | FLG WN A105 RF 150 S160 80NB | As per RFQ | 10 | PC | 15 |
| 86 | FLG WN CS A105 150 STD 500NB | As per RFQ | 4 | PC | 15 |
| 87 | TEE EQ BW CS WPB STD 350NB | As per RFQ | 4 | PC | 15 |
| 88 | FLG BLIND CS A105 RF 300 IBR 250NB | As per RFQ | 4 | PC | 15 |
| 89 | CPLG THD RED CS A105 GALV 3000 25X15NB | As per RFQ | 50 | PC | 15 |
| 90 | ELB BW CS WPB 90DEG LR IBR STD 200NB | As per RFQ | 40 | PC | 15 |
| 91 | ELB BW CS WPB 90DEG LR IBR S40 80NB | As per RFQ | 40 | PC | 15 |
| 92 | ELB BW CS WPB 90DEG LR IBR S40 250NB | As per RFQ | 40 | PC | 15 |
| 93 | ELB BW CS WPB 90DEG LR IBR S40 100NB | As per RFQ | 40 | PC | 15 |
Corresponding Contract Award Notice
No Contract Award Notice found for this tender. Please try using the Contract Award Search Page.
Sign in with Google